background image

En-2

NAME OF PARTS

Indoor unit

2

-[1]

2

-[2]

2

-[3]

2

-[4]

1

4

3

1

Air 

fi

 lter (in air intake grille)

2

Air 

fl

 ow direction outlet 

Individual air 

fl

 ow direction control: [1][2][3][4]

3

Air intake grille

4

Human sensor

5

Remote controller *

*: For detailed instructions on how to operate, please refer to 

the Operating manual of the remote controller.

FEATURES AND FUNCTIONS

INVERTER

On start-up, the air conditioner will operate at maximum 
capacity to bring the room quickly down to desired tempera-
ture. Once the temperature in the room begins to achieve the 
set temperature, the air conditioner will reduce its capacity 
and energy usage to the minimum capacity and input ratings.

VERTICAL AIR FLOW

Comfortable air 

fl

 ow spread to every corner of the room by 

the wide vertical air 

fl

 ow.

INDIVIDUAL AIR FLOW DIRECTION CONTROL

Each louver can be set individually using the wired remote 
controller to provide comfortable air 

fl

 ow.

HUMAN SENSOR

The human sensor saves energy by catching the movement 
of people, operating either in a low capacity mode or stop-
ping operation when people leave the room.

[Auto Saving]

When absent continues for the set time, the operation 
switches to energy saving operation.

[Auto Off]

When absent continues for the set time, indoor unit opera-
tion stops.

ECONOMY OPERATION

When ECONOMY operation mode is operated, the room 
temperature will be little higher than the set-temp under 
cooling mode and lower than set-temp under heating mode. 
Therefore, the ECONOMY mode is able to save more energy 
than other normal mode.

 CAUTION

•  Provide occasional ventilation during use.
•  Always operate this product with air 

fi

 lters installed.

•  Ensure that any electronic equipment is at least 

1 m away from this product.

•  Turn off power source when not using this prod-

uct for extended periods.

•  After a long period of use, ensure to get the 

mounting of the indoor unit checked to prevent 
this product from falling down.

• The air 

fl

 ow direction and the room temperature 

should be carefully considered when you use this 
product in a room with infants, children, elderly or 
sick persons.

•  Keep the surroundings of the outdoor unit clean 

and tidy, and do not place items around it. Any 
objects blocking or entering from the outlet ports 
may cause product malfunction.

•  Do not direct the air 

fl

 ow at 

fi

 replaces or heating 

apparatus.

•  Do not block or cover the inlet port and the outlet 

port.

•  Do not apply any heavy pressure to radiator 

fi

 ns.

•  Do not climb on, place objects on, or hang ob-

jects from this product.

•  Do not place any other electrical products or 

household belongings under this product.
Dripping condensation from this product might 
get them wet, and may cause damage or mal-
function of your property.

•  Do not expose this product directly to water.
•  Do not use this product for preservation of food, 

plants, animals, precision equipment, art work, or 
other objects. This may cause quality deteriora-
tion of those items.

•  Do not expose animals or plants to the direct air 

fl

 ow.

•  Do not drink the drainage from the air conditioner.
•  Do not pull the power supply cable.
•  Do not touch the aluminium 

fi

 ns of heat exchang-

er built-in this product to avoid personal injury 
when you install or maintain the unit.

•  Do not stand on unstable steps when operating 

or cleaning this product. It may overturn and can 
cause injury.

9381622016-03_OM_EN.indd   2

9381622016-03_OM_EN.indd   2

2015/11/26   15:26:16

2015/11/26   15:26:16

Содержание autg30krla

Страница 1: ...AIR CONDITIONER KEEP THIS MANUAL FOR FUTURE REFERENCE PART No 9381622016 03 Indoor Unit AUTG30KRLA AUTG36KRLA AUTG45KRLA AUTG54KRLA OPERATING MANUAL Cassette type ...

Страница 2: ... the electrical breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and con sult authorized ...

Страница 3: ...onal ventilation during use Always operate this product with air filters installed Ensure that any electronic equipment is at least 1 m away from this product Turn off power source when not using this prod uct for extended periods After a long period of use ensure to get the mounting of the indoor unit checked to prevent this product from falling down The air flow direction and the room temperatur...

Страница 4: ...Use the DAY OFF setting to switch off timed operation for a selected day in the coming week Because all days can be set together the weekly timer can be used to repeat the timer settings for all of the days REMOVABLE INTAKE GRILLE The indoor unit s intake grille can be removed for easy clean ing and maintenance WIRED REMOTE CONTROLLER The wired remote controller allows convenient control of indoor...

Страница 5: ...start of heating operation during defrost or when AUTO auto changeover is selected NOTES Attempting to move up down air direction flaps manu ally could result in improper operation in this case stop operation and restart The louvers should begin to operate properly again When used in a room with infants children elderly or sick persons the air direction and room temperature should be considered ca...

Страница 6: ...humidifying your room You cannot heat the room during Dry mode During Dry mode the unit will operate at low speed in order to adjust room humidity the indoor unit s fan may stop from time to time Also the fan may operate at very low speed when adjusting room humidity The fan speed cannot be changed manually when Dry mode has been selected Fan Use to circulate the air throughout your room NOTES Dur...

Страница 7: ...Cooling As the room temperature approaches that of the set temperature the fan speed becomes slower Fan The fan runs at medium fan speed Fan control for energy saving At Cooling or Dry mode by using this function the indoor unit fan will operate intermittently at a very low speed when the outdoor unit is stopped When the fan setting is at Auto this function will automati cally be active to prevent...

Страница 8: ...rse Cycle WARNING In the event of a malfunction burning smell etc immediately stop operation turn off the electrical breaker and consult authorized service personnel Merely turning off the unit s power switch will not completely disconnect the unit from the power source Always be sure to turn off the electrical breaker to ensure that power is completely off Before requesting service perform the fo...

Страница 9: ...humidity set a lower room tempera ture CHECK ONCE MORE Does not operate at all Has the circuit breaker been turned off Has there been a power failure Has a fuse blown out or a circuit breaker been tripped Is the timer operating Is the Auto off operation of the Human sensor setting ac tive Poor cooling or heating performance Is the air filter dirty Are the air conditioner s intake grille or outlet ...