background image

En-5

Heating and Cooling model (Reverse cycle):

•  When AUTO (auto changeover) is selected, the air condi-

tioner selects the appropriate operation mode (cooling or 
heating) according to your room’s present temperature.

•  When Auto mode is 

fi

 rst selected, the fan will operate at 

low speed for about a few minutes, during which time the 
indoor unit detects the room conditions and selects the 
proper operation mode.
Room temperature is higher than the de

fi

 ned tempera-

ture in temperature setting 

 Cooling mode

Room temperature is close to the de

fi

 ned temperature in 

temperature setting 

 Determined by outdoor tempera-

ture
Room temperature is lower than the de

fi

 ned temperature 

in temperature setting 

 Heating mode 

De

fi

 ned temper-

ature in tempera-
ture setting 

Determined by 
outdoor temperature 

Cooling mode

Heating mode

•  When the air conditioner has adjusted your room’s 

temperature to near the thermostat setting, it will begin 
monitor operation. In the monitor operation mode, the 
fan will operate at low speed. If the room temperature 
subsequently changes, the air conditioner will once again 
select the appropriate operation (Heating, Cooling) to ad-
just the temperature to the value set in the thermostat. 
If the mode automatically selected by the unit is not 
what you wish, select one of the mode operation (HEAT, 
COOL, DRY, FAN).

Heat*

•  Use to warm your room.
•  When Heating mode is selected, the air conditioner will 

operate at very low fan speed for about 3 to 5 minutes, 
after which it will switch to the selected fan setting. This 
period of time is provided to allow the indoor unit to warm 
up before beginning full operation.

•  When the room temperature is very low, frost may form 

on the outdoor unit, and its performance may be re-
duced. In order to remove such frost, the unit will auto-
matically enter the defrost cycle from time to time. During 
Automatic defrosting operation, the Heating operation 
will be interrupted.

•  After the start of Heating operation, it takes sometime 

before the room gets warmer.

Cool

  Use to cool your room.

Dry

•  Use for gently cooling while dehumidifying your room.
•  You cannot heat the room during Dry mode.
•  During Dry mode, the unit will operate at low speed; in 

order to adjust room humidity, the indoor unit’s fan may 
stop from time to time. Also, the fan may operate at very 
low speed when adjusting room humidity.

•  The fan speed cannot be changed manually when Dry 

mode has been selected.

Fan

  Use to circulate the air throughout your room.

 NOTES

*During Heating mode:

Set the thermostat to a temperature setting that is higher 
than the current room temperature. The Heating mode will 
not operate if the thermostat is set lower than the actual 
room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature setting that is lower than 
the current room temperature. The Cooling and Dry modes will 
not operate if the thermostat is set higher than the actual room 
temperature (in Cooling mode, the fan alone will operate).

During Fan mode:

You cannot use the unit to heat or cool your room.

Human sensor (Auto saving/Auto off)

To prevent waste of electricity, this function controls the 
temperature setting when no one is occupying the room. 
Energy saving operation is on at the time of purchase.

 WARNING

Do not use this function when there are only infants, chil-
dren, elderly or sick persons in the room.

 CAUTION

Do not use this function in server rooms or other places 
where there is no one in the room.

About the Auto saving operation

If no one enters the room during the set time (15, 30, 60, 90, 
120, 180 minutes), the set temperature will be automatically 
controlled.
(When someone comes back into the room, the human 
sensor will detect this, and automatically revert to the 
original settings.)

Operation 

mode

Operating details 

(if there is no one in the room for a while)

COOL/DRY

The set temperature will be increased by 
a maximum of approximately 2

˚

C.

HEAT

The set temperature will be decreased 
by a maximum of approximately 2

˚

C.

AUTO

This runs the Energy saving operation 
automatically for the selected mode 
(Cooling/ Heating/ Drying).

About the Auto off operation

If no one enters the room during the set time (1 to 24 
hours in 1 hour increments), the air conditioner will 
automatically stop operation.

 NOTES

•  This function cannot be used with group control.
•  To restart operation, press the [On/Off] button. 

9381622016-03_OM_EN.indd   5

9381622016-03_OM_EN.indd   5

2015/11/26   15:26:17

2015/11/26   15:26:17

Содержание autg30krla

Страница 1: ...AIR CONDITIONER KEEP THIS MANUAL FOR FUTURE REFERENCE PART No 9381622016 03 Indoor Unit AUTG30KRLA AUTG36KRLA AUTG45KRLA AUTG54KRLA OPERATING MANUAL Cassette type ...

Страница 2: ... the electrical breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and con sult authorized ...

Страница 3: ...onal ventilation during use Always operate this product with air filters installed Ensure that any electronic equipment is at least 1 m away from this product Turn off power source when not using this prod uct for extended periods After a long period of use ensure to get the mounting of the indoor unit checked to prevent this product from falling down The air flow direction and the room temperatur...

Страница 4: ...Use the DAY OFF setting to switch off timed operation for a selected day in the coming week Because all days can be set together the weekly timer can be used to repeat the timer settings for all of the days REMOVABLE INTAKE GRILLE The indoor unit s intake grille can be removed for easy clean ing and maintenance WIRED REMOTE CONTROLLER The wired remote controller allows convenient control of indoor...

Страница 5: ...start of heating operation during defrost or when AUTO auto changeover is selected NOTES Attempting to move up down air direction flaps manu ally could result in improper operation in this case stop operation and restart The louvers should begin to operate properly again When used in a room with infants children elderly or sick persons the air direction and room temperature should be considered ca...

Страница 6: ...humidifying your room You cannot heat the room during Dry mode During Dry mode the unit will operate at low speed in order to adjust room humidity the indoor unit s fan may stop from time to time Also the fan may operate at very low speed when adjusting room humidity The fan speed cannot be changed manually when Dry mode has been selected Fan Use to circulate the air throughout your room NOTES Dur...

Страница 7: ...Cooling As the room temperature approaches that of the set temperature the fan speed becomes slower Fan The fan runs at medium fan speed Fan control for energy saving At Cooling or Dry mode by using this function the indoor unit fan will operate intermittently at a very low speed when the outdoor unit is stopped When the fan setting is at Auto this function will automati cally be active to prevent...

Страница 8: ...rse Cycle WARNING In the event of a malfunction burning smell etc immediately stop operation turn off the electrical breaker and consult authorized service personnel Merely turning off the unit s power switch will not completely disconnect the unit from the power source Always be sure to turn off the electrical breaker to ensure that power is completely off Before requesting service perform the fo...

Страница 9: ...humidity set a lower room tempera ture CHECK ONCE MORE Does not operate at all Has the circuit breaker been turned off Has there been a power failure Has a fuse blown out or a circuit breaker been tripped Is the timer operating Is the Auto off operation of the Human sensor setting ac tive Poor cooling or heating performance Is the air filter dirty Are the air conditioner s intake grille or outlet ...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Отзывы: