En-4

OPERATING TIPS

Instructions relating to heating (*) are applicable only to 
Heating and Cooling model (Reverse Cycle).

Heating performance*

•  This air conditioner operates on the heat-pump principle, 

absorbing heat from outdoor air and transferring that heat 
indoors. As a result, the operating performance is reduced 
as outdoor air temperature drops. Also, please consult with 
your installation technician to ensure the unit is correctly 
sized for the room space required.

•  Heat-pump air conditioners heat your entire room by recir-

culating air throughout the room, with the result that some 
time may be required after 

fi

 rst starting the air conditioner 

until the room is heated.

When indoor and outdoor temperatures are high*

When both indoor and outdoor temperatures are high during use 
of the Heating mode, the outdoor unit’s fan may stop at times.

Microcomputer-controlled automatic defrosting*

•  When using the Heating mode under conditions of low 

outdoor temperature and high humidity, frost may form on 
the outdoor unit, reducing the operating performance.
In order to prevent this reduced performance, this product 
is equipped with a microcomputer-controlled automatic 
defrosting function. During the defrost cycle, the indoor fan 
will shut down, and the defrost mode will be indicated. It 
will take maximum of 15 minutes before the air conditioner 
starts up again.

•  After Heating operation stops, if frost forms on the outdoor 

unit, the unit will start Automatic defrosting operation. 
At this time, the outdoor unit will automatically stop after 
operating for a few minutes.

Flow direction setting

Vertical air direction adjustment

Air

fl

 ow direction setting:

1

2

3

4

: During cooling/heat-

ing/dry mode

•  The vertical air

fl

 ow direction is set automatically as shown, 

in accordance with the type of operation selected.

During cooling/dry mode:  Horizontal 

fl

 ow 

2

During heating mode*: 

Downward 

fl

 ow 

4

(30, 36 type)

 

 

3

(45, 54 type)

•  During AUTO mode operation, for the 

fi

 rst minute after 

beginning operation, air

fl

 ow will be horizontal 

2

; the air 

direction cannot be adjusted during this period.
Even if the 

fl

 ow direction is set, it may operate at a dif-

ferent position at the start of heating operation, during 
defrost, or when AUTO(auto changeover) is selected.

 NOTES

•  Attempting to move up/down air direction 

fl

 aps manu-

ally could result in improper operation; in this case, stop 
operation and restart. The louvers should begin to operate 
properly again.

•  When used in a room with infants, children, elderly or sick 

persons, the air direction and room temperature should be 
considered carefully when making settings.

Horizontal air direction adjustment

The function cannot be used.

 Swing operation

The type of operation

Range of swing

Cooling/Heating/Dry/Fan

1

 to 

4

The swing operation may stop temporarily when the air con-
ditioner’s fan is not operating, or when operating at very low 
speeds.

Individual air 

fl

 ow direction control

When this function is used to set the louvers, it will be prioritized 
over other VT settings from other remote controllers or external 
devices. In order to change to other settings, disable the indi-
vidual air 

fl

 ow direction control.

Hot start*

The indoor unit prevents cold drafts when Heating operation 
begins.
The indoor unit fan will not operate or it will operate at a very low 
speed until the heat exchanger reaches the set temperature. 

Low ambient cooling

When the outdoor temperature drops, the outdoor unit’s fans 
may switch to low speed, or one of the fans may stop inter-
mittently.

Mode operation

Auto

Cooling model:

•  When AUTO (auto changeover) operation 

fi

 rst selected, 

the fan will operate at very low speed for about a few 
minutes, during which time the indoor unit detects the 
room conditions and selects the proper mode.
Room temperature is higher than the de

fi

 ned temperature 

in temperature setting 

 Cooling mode

Room temperature is close to or lower than the de

fi

 ned 

temperature in temperature setting 

 Monitor operation

Cooling mode

Monitor operation

De

fi

 ned tem-

perature in 
temperature 
setting 

•  When the indoor unit has adjusted your room’s tempera-

ture to near the temperature setting, it will begin monitor 
operation. In the monitor operation mode, the fan will 
operate at low speed. If the room temperature subse-
quently changes, the indoor unit will once again select 
the appropriate operation (cooling) to adjust the tempera-
ture to the value set in the temperature setting.

•  If the mode automatically selected by the unit is not what 

you wish, select one of the mode operation (COOL, DRY, 
FAN).

9381622016-03_OM_EN.indd   4

9381622016-03_OM_EN.indd   4

2015/11/26   15:26:17

2015/11/26   15:26:17

Содержание autg30krla

Страница 1: ...AIR CONDITIONER KEEP THIS MANUAL FOR FUTURE REFERENCE PART No 9381622016 03 Indoor Unit AUTG30KRLA AUTG36KRLA AUTG45KRLA AUTG54KRLA OPERATING MANUAL Cassette type ...

Страница 2: ... the electrical breaker or disconnecting the power plug Then consult authorized service personnel Take care not to damage the power supply cable If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and con sult authorized ...

Страница 3: ...onal ventilation during use Always operate this product with air filters installed Ensure that any electronic equipment is at least 1 m away from this product Turn off power source when not using this prod uct for extended periods After a long period of use ensure to get the mounting of the indoor unit checked to prevent this product from falling down The air flow direction and the room temperatur...

Страница 4: ...Use the DAY OFF setting to switch off timed operation for a selected day in the coming week Because all days can be set together the weekly timer can be used to repeat the timer settings for all of the days REMOVABLE INTAKE GRILLE The indoor unit s intake grille can be removed for easy clean ing and maintenance WIRED REMOTE CONTROLLER The wired remote controller allows convenient control of indoor...

Страница 5: ...start of heating operation during defrost or when AUTO auto changeover is selected NOTES Attempting to move up down air direction flaps manu ally could result in improper operation in this case stop operation and restart The louvers should begin to operate properly again When used in a room with infants children elderly or sick persons the air direction and room temperature should be considered ca...

Страница 6: ...humidifying your room You cannot heat the room during Dry mode During Dry mode the unit will operate at low speed in order to adjust room humidity the indoor unit s fan may stop from time to time Also the fan may operate at very low speed when adjusting room humidity The fan speed cannot be changed manually when Dry mode has been selected Fan Use to circulate the air throughout your room NOTES Dur...

Страница 7: ...Cooling As the room temperature approaches that of the set temperature the fan speed becomes slower Fan The fan runs at medium fan speed Fan control for energy saving At Cooling or Dry mode by using this function the indoor unit fan will operate intermittently at a very low speed when the outdoor unit is stopped When the fan setting is at Auto this function will automati cally be active to prevent...

Страница 8: ...rse Cycle WARNING In the event of a malfunction burning smell etc immediately stop operation turn off the electrical breaker and consult authorized service personnel Merely turning off the unit s power switch will not completely disconnect the unit from the power source Always be sure to turn off the electrical breaker to ensure that power is completely off Before requesting service perform the fo...

Страница 9: ...humidity set a lower room tempera ture CHECK ONCE MORE Does not operate at all Has the circuit breaker been turned off Has there been a power failure Has a fuse blown out or a circuit breaker been tripped Is the timer operating Is the Auto off operation of the Human sensor setting ac tive Poor cooling or heating performance Is the air filter dirty Are the air conditioner s intake grille or outlet ...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Отзывы: