background image

En-3

*1) Before starting operation, make sure that the intake grille is closed 

completely. Incomplete closing may affect the proper function or 
performance of the product.

*2) Indicator lamps light in the following conditions.

Name

Color

Operation or condition

Operation

Green

Normal operation

Timer

Orange

Timer operation

Economy

Green

Economy operation
10 °C Heat operation

W-LAN

Orange

Wireless LAN control is active.

3.2. Remote controller

When you use the optional remote controller, the appearance 

and the operation procedure may differ.

For details, please refer to the operating manual of each remote 

controller.

  : The setting must be done while the setting screen is displayed 

for each function.

: The button is controllable only when the air conditioner is operating.

: The instruction is relating to the wireless LAN control (optional).

For Energy saving operations  ...... Refer to page 7.

Activates or deactivates the Economy 

operation.

Activates or deactivates the Energy saving 

program that uses the human sensor

.

For Outdoor Unit Low Noise operation

  ... Refer to page 8.

Activates or deactivates the Outdoor Unit Low 

Noise operation.

 

Remote controller display

In this section, all the possible indicators are displayed for description. 
In actual operation, the display is linked with the button operation, and 
only shows the necessary indicators for each setting.

 Do not press this button in normal use.

It starts the test run (for use by authorized service personnel only).

NOTES:

 

If the test run starts unintentionally, press   to quit the test 

run.

Signal transmitter

Aim at the signal receiver of the indoor unit properly. 

• Operating range is approximately 7 m.

• [   ] will appear when the signal is transmitted.

• The indoor unit will emit a beep when it receive the signal 

properly. If there is no beep, press the button again.

For Basic operations  ..................... Refer to page 5.

Starts or stops the air conditioner operation.

Changes the operation mode. 

 

Adjusts the setting temperature.

 

For 10 °C Heat operation  .............. Refer to page 8.

Activates the 10 °C Heat operation.

3.  NAME OF PARTS

 

CAUTION

For appropriate signal transmission between the remote 

controller and the indoor unit, keep the signal receiver 

away from the following items:

 

- Direct sunlight or other strong lights

 

- Flat-panel television screen
In rooms with instantaneous 

fl

 uorescent lights, such as 

inverter type ones, the signal may not be transmitted 

properly. In such a case, consult the store of purchase.

 Battery loading and remote controller preparation

(R03/LR03/AAA x 2)

1

2

3

5
7

6

4

8

1

~

3

 

 Put batteries as shown in the 

fi

 gure above.

4

   

Press 

 to start clock setting.

5

   

Press 

(

)

 to set day of the week (Monday 

to Sunday). 

*  By pressing 

, the time indicator can be 

changed from a 24-hour to a 12-hour clock.

6

   

Press 

 to continue.

7

   

Press 

(

)

 to set the clock.

Press the buttons to change the clock by a minute.
Press and hold the buttons to change the clock by 10 minutes.

8

   

Press 

 to complete the setting.

Be close to the indoor unit. If you press the button from a 
distance, settings may not be properly sent.

NOTES:

• Use speci

fi

 ed type of batteries only. 

• Do not mix different types or new and used batteries together.
• Batteries can be used about 1 year in ordinary use.
•  If the remote control range noticeably shortens, replace the 

batteries, and press 

 as shown in page 4.

• When you replace the batteries, the settings will be initialized.

3.1. Indoor unit

 : The instruction is relating to the wireless LAN control (optional).

For Manual Auto operation and 

Filter indicator reset (Refer to page 14.)

Rating label

Front panel

W-LAN 

adapter slot

 

Air cleaning 

fi

 lter

Intake grille 

*1)

Indicator lamps 

*2)

Human sensor 

(Refer to page 7.)

Drain hose

Remote controller 

signal receiver

Air 

fi

 lter

9387081244_OM.indb   3

9387081244_OM.indb   3

8/26/2019   6:31:55 PM

8/26/2019   6:31:55 PM

Содержание ASF30K-KM

Страница 1: ...ε να ανατρέχετε σε αυτό στο μέλλον MANUAL DE FUNCIONAMENTO AR CONDICIONADO Tipo mural Antes de utilizar este produto leia atentamente estas instruções e guarde este manual para referência futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА Настенного типа Перед эксплуатацией устройства внимательно ознакомьтесь с данным руководством и сохраняйте его для использования в будущем KULLANIM KILAVUZU ...

Страница 2: ...are not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and...

Страница 3: ...door unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any oth...

Страница 4: ...ep press the button again For Basic operations Refer to page 5 Starts or stops the air conditioner operation Changes the operation mode Adjusts the setting temperature For 10 C Heat operation Refer to page 8 Activates the 10 C Heat operation 3 NAME OF PARTS CAUTION For appropriate signal transmission between the remote controller and the indoor unit keep the signal receiver away from the following...

Страница 5: ...he clock setting After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Obstacles such...

Страница 6: ...s to set the desired temperature The temperature changes by 0 5 C increments Temperature setting range Auto Cooling Dry 18 0 30 0 C Heating 16 0 30 0 C NOTES In the Cooling or Dry mode set the temperature lower than the current room temperature the indoor unit fan may stop from time to time to perform Fan control for energy saving that enables power saving operation by stopping the rotation of the...

Страница 7: ...ll be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Program 4 On Off On Off 26 C 28 C Wake up Leave for w...

Страница 8: ...the set temperature Max 4 C Auto Depending on the operating mode Cooling Heating Dry Detection range of Human sensor 90 7 m 7 m 50 50 Side view Top view NOTES Since Human sensor detects infrared light given out by people the detection may be incorrect in the following situations Situations in which the sensor may detect no one in the room even when there is someone there When the room temperature ...

Страница 9: ... this function is restricted 9 SETTINGS ON INSTALLATION 9 1 Remote controller custom code setting By setting custom code of indoor unit and remote controller you can specify the air conditioner which the remote controller controls When two or more air conditioners are in the room and you wish to operate them separately set the custom code 4 selections possible NOTES If custom codes is different be...

Страница 10: ...ir cleaning filters into the air cleaning filter frames NOTES Use the Apple catechin filter as soon as possible after opening the package The air cleaning effect decreases when the filters are left in the opened package The frequency of the cleaning is as shown in the following table What to do Frequency Cleaning indoor unit body When you notice Cleaning intake grille Cleaning air filter Every 2 w...

Страница 11: ...th high humidity frost may form on the outdoor unit during the heating operation and it could reduce the operating performance of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes indicator on the indoor uni...

Страница 12: ...n your screen Step 2 User registration 1 Open the installed mobile app 2 Register the user with either a smartphone or tablet PC by following the instructions in the create an account section of the mobile app Wireless LAN label MAC SSID AP WF PIN Connection port Step 3 Installing W LAN adapter CAUTION Be sure to turn off the power supply of the air conditioner when installing or removing this pro...

Страница 13: ...t press any buttons of the remote controller for 60 seconds the remote controller display will return to the original display 1 Press until only the clock is displayed on the remote controller display 2 Press down on the remote controller for more than 5 seconds will be displayed on the remote controller display 3 Select using on the remote controller 4 Press indicator on the indoor unit will turn...

Страница 14: ... unit is connected to the power supply it is not insulated from the power supply even if the unit is turned off Unit smells of something burning or emits smoke Water leaks from the unit Does not operate at all Has there been a power outage In this case the unit restarts automatically after the power supply is resumed Refer to page 10 Has the circuit breaker been turned off Turn on the circuit brea...

Страница 15: ...ere is a possibility that the W LAN adapter is not properly connected to the wireless router 11 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the W LAN adapter is being updated During the air conditioner registration pairing of W LAN adapter 11 Restricted function 11 Manual Auto operation and Filter indicator reset You can operate the ai...

Отзывы: