Fujitsu ASF30K-KM Скачать руководство пользователя страница 2

En-1

1. SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section 

carefully before you use this product, and be sure to comply 

with the following safety precautions.
Incorrect operation due to failure to follow the instructions may 

cause harm or damage, the seriousness of which is classi

fi

 ed 

as follows:

 WARNING

This mark warns of death or serious injury.

 CAUTION

This mark warns of injury or damage to property.

This mark denotes an action that is PROHIBITED.

This mark denotes an action that is COMPULSORY.

Explanation of symbols displayed on the indoor unit or outdoor unit.

WARNING

This symbol shows that this product uses a 

fl

 ammable refrigerant. If the refrigerant is leaked and 

exposed to an external ignition source, there is a risk 

of 

fi

 re.

CAUTION

This symbol shows that the operating manual should 

be read carefully.

CAUTION

This symbol shows that a service personnel should 

be handling this equipment with reference to the 

installation manual.

CAUTION

This symbol shows that information is available such 

as the operating manual or installation manual.

 WARNING

•  The appliance shall be installed, operated and stored 

in a room with a 

fl

 oor area larger than X m².

Amount of refrigerant charge

M (kg)

Minimum room area

X (m

2

)

 1.22 

-

1.22 < M 

 1.23 

1.45

1.23 < M 

 1.50 

2.15

1.50 < M 

 1.75 

2.92

1.75 < M 

 2.0 

3.82

2.0 < M 

 2.5 

5.96

2.5 < M 

 3.0 

8.59

3.0 < M 

 3.5 

11.68

3.5 < M 

 4.0 

15.26

(IEC 60335-2-40)

•  This product contains no user-serviceable parts. 

Always consult authorized service personnel for 

repairing, installation, and relocation of this product.

Improper installation or handling will cause leakage, 

electric shock, or 

fi

 re.

•  In the event of a malfunction such as burning smell, 

immediately stop operation of the air conditioner, and 

disconnect all the power supply by turning off the 

electrical breaker or disconnecting the power plug.

Then consult authorized service personnel.

•  Take care not to damage the power supply cable.

If it is damaged, it should be replaced only by 

authorized service personnel in order to avoid a 

hazard.

•  In the event of refrigerant leakage, be sure to keep 

away from 

fi

 re or any 

fl

 ammables, and consult 

authorized service personnel.

•  In the event of a thunder storm or any prior sign 

of a lightning strike, turn off the air conditioner via 

the remote controller, and refrain from touching the 

product or the power source to prevent any electrical 

hazards.

•  This product shall be stored in a room without 

continuously operating ignition sources (for example: 

open 

fl

 ames, an operating gas appliance or an 

operating electric heater).

•  This product shall be stored in a well-ventilated area.
•  Be aware that refrigerants may not contain an odour.
•  This product shall be stored so as to prevent 

mechanical damage from occurring.

•  Disposing of the product shall be done properly, in 

compliance with national or regional regulations.

•  During transportation or relocation of the indoor unit, 

pipes shall be covered with the wall hook bracket for 

protection.

Do not move this product by holding the indoor unit pipes.

(The stress applied to the pipe joints may cause the 

fl

 ammable gas to leak during operation).

Contents

1. SAFETY PRECAUTIONS 

.......................................... 1

2. PREPARATION 

......................................................... 2

3.  NAME OF PARTS ..................................................... 3

3.1. Indoor 

unit 

........................................................ 3

3.2. Remote 

controller 

............................................. 3

4. BASIC OPERATIONS 

............................................... 5

5. AIRFLOW SETTINGS 

............................................... 5

5.1.  Fan speed setting ............................................. 5
5.2. Air

fl

 ow direction setting .................................... 5

6. TIMER OPERATIONS 

............................................... 5

6.1. Weekly 

timer 

..................................................... 6

6.2.  On timer or Off timer ......................................... 6
6.3. Program 

timer 

................................................... 6

6.4.  Sleep timer  ...................................................... 6

7.  ENERGY SAVING OPERATIONS ............................ 7

7.1. Economy 

operation 

.......................................... 7

7.2.  Human sensor for energy saving ..................... 7
7.3.  Fan control for energy saving ........................... 7

8. OTHER OPERATIONS 

............................................. 8

8.1. Powerful 

operation 

........................................... 8

8.2.  Outdoor Unit Low Noise operation ................... 8
8.3.  10 °C Heat operation ........................................ 8

9.  SETTINGS ON INSTALLATION ................................ 8

9.1.  Remote controller custom code setting ............ 8

10. CLEANING AND CARE ............................................. 8
11. GENERAL INFORMATION ..................................... 10
12. OPTIONAL PARTS ................................................. 11

12.1. Wired remote controller .................................. 11
12.2. Wireless LAN control ...................................... 11

13. TROUBLESHOOTING ............................................ 13

9387081244_OM.indb   1

9387081244_OM.indb   1

8/26/2019   6:31:55 PM

8/26/2019   6:31:55 PM

Содержание ASF30K-KM

Страница 1: ...ε να ανατρέχετε σε αυτό στο μέλλον MANUAL DE FUNCIONAMENTO AR CONDICIONADO Tipo mural Antes de utilizar este produto leia atentamente estas instruções e guarde este manual para referência futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА Настенного типа Перед эксплуатацией устройства внимательно ознакомьтесь с данным руководством и сохраняйте его для использования в будущем KULLANIM KILAVUZU ...

Страница 2: ...are not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and...

Страница 3: ...door unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any oth...

Страница 4: ...ep press the button again For Basic operations Refer to page 5 Starts or stops the air conditioner operation Changes the operation mode Adjusts the setting temperature For 10 C Heat operation Refer to page 8 Activates the 10 C Heat operation 3 NAME OF PARTS CAUTION For appropriate signal transmission between the remote controller and the indoor unit keep the signal receiver away from the following...

Страница 5: ...he clock setting After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Obstacles such...

Страница 6: ...s to set the desired temperature The temperature changes by 0 5 C increments Temperature setting range Auto Cooling Dry 18 0 30 0 C Heating 16 0 30 0 C NOTES In the Cooling or Dry mode set the temperature lower than the current room temperature the indoor unit fan may stop from time to time to perform Fan control for energy saving that enables power saving operation by stopping the rotation of the...

Страница 7: ...ll be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Program 4 On Off On Off 26 C 28 C Wake up Leave for w...

Страница 8: ...the set temperature Max 4 C Auto Depending on the operating mode Cooling Heating Dry Detection range of Human sensor 90 7 m 7 m 50 50 Side view Top view NOTES Since Human sensor detects infrared light given out by people the detection may be incorrect in the following situations Situations in which the sensor may detect no one in the room even when there is someone there When the room temperature ...

Страница 9: ... this function is restricted 9 SETTINGS ON INSTALLATION 9 1 Remote controller custom code setting By setting custom code of indoor unit and remote controller you can specify the air conditioner which the remote controller controls When two or more air conditioners are in the room and you wish to operate them separately set the custom code 4 selections possible NOTES If custom codes is different be...

Страница 10: ...ir cleaning filters into the air cleaning filter frames NOTES Use the Apple catechin filter as soon as possible after opening the package The air cleaning effect decreases when the filters are left in the opened package The frequency of the cleaning is as shown in the following table What to do Frequency Cleaning indoor unit body When you notice Cleaning intake grille Cleaning air filter Every 2 w...

Страница 11: ...th high humidity frost may form on the outdoor unit during the heating operation and it could reduce the operating performance of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes indicator on the indoor uni...

Страница 12: ...n your screen Step 2 User registration 1 Open the installed mobile app 2 Register the user with either a smartphone or tablet PC by following the instructions in the create an account section of the mobile app Wireless LAN label MAC SSID AP WF PIN Connection port Step 3 Installing W LAN adapter CAUTION Be sure to turn off the power supply of the air conditioner when installing or removing this pro...

Страница 13: ...t press any buttons of the remote controller for 60 seconds the remote controller display will return to the original display 1 Press until only the clock is displayed on the remote controller display 2 Press down on the remote controller for more than 5 seconds will be displayed on the remote controller display 3 Select using on the remote controller 4 Press indicator on the indoor unit will turn...

Страница 14: ... unit is connected to the power supply it is not insulated from the power supply even if the unit is turned off Unit smells of something burning or emits smoke Water leaks from the unit Does not operate at all Has there been a power outage In this case the unit restarts automatically after the power supply is resumed Refer to page 10 Has the circuit breaker been turned off Turn on the circuit brea...

Страница 15: ...ere is a possibility that the W LAN adapter is not properly connected to the wireless router 11 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the W LAN adapter is being updated During the air conditioner registration pairing of W LAN adapter 11 Restricted function 11 Manual Auto operation and Filter indicator reset You can operate the ai...

Отзывы: