9.  OPTIONAL KIT INSTALLATION (OPTION)

 

WARNING

Regulation  of  cable  differs  from  each  locality, refer  in  accordance  with  local 

rules.

This air conditioner can be connected with the following optional kits.

Option type

Connector No.

UTY-XSZX (Remote sensor unit)

CN8

UTD-ECS5A (External input)

CN114

UTD-ECS5A (External output)

CN115

UTD-ECS5A (Preparation)

CN5, CN106

(CN8)

(CN115)

(CN114)

Remote controller 

cable

Connection cable 

(to outdoor unit)

(CN106)

(CN5)

10.   CHECK LIST

Pay  special  attention  to  the  check  items  below  when  installing  the  indoor  unit(s). After 

installation is complete, be sure to check the following check items again.

CHECK ITEMS

If not performed correctly

CHECK BOX

Has the indoor unit been 

installed correctly?

Vibration, noise, indoor unit 

 

may drop

Has there been a check for 

gas leaks (refrigerant pipes)?

No cooling, No heating

Has heat insulation work been 

 

completed?

Water leakage

Does water drain easily from  

the indoor units?

Water leakage

Are the wires and pipes all 

connected completely?

No operation, heat or burn  

damage

Is the connection cable the  

specified thickness?

No operation, heat or burn  

damage

Are the inlets and outlets free  

of any obstacles?

No cooling, No heating

After installation is completed, 

has the proper operation and 

handling been explained to  

the user?

11.   TEST RUN

CHECK ITEMS

(1)  Is operation of each button on the remote controller normal?
(2)  Is the drain normal?
(3)  Is there any abnormal noise and vibration during operation?

•  Do not operate the air conditioner in test run for a long time.

[OPERATION METHOD]

•  For the operation method, refer to the operating manual.
(1)  Stop the air conditioner operation.

(2) 

Press the MODE button and the FAN button simultaneously for 2 seconds or more to 

start the test run.

Test run display

(3)  Press the START/STOP button to stop the test run.

If “C0” appears in the unit number display, there is a remote controller error. Refer to the 

installation manual included with the remote controller.

Unit number

Error code

Content

Incompatible indoor unit is connected

Indoor unit 

 remote controller communication 

error

12.   CUSTOMER GUIDANCE

Explain the following to the customer in accordance with the operating manual:

(1) Starting and stopping method, operation switching, temperature adjustment, timer, air 

flow switching, and other remote controller operations.

(

2) Air filter removal and cleaning, and how to use the air louvers.

(3) Give the operating and installation manuals to the customer.

9379123143_IM.indb   13

10/16/2017   08:55:03

Содержание ARYG LHTA 1ph

Страница 1: ... ducto Únicamente para personal de servicio autorizado MANUALE D INSTALLAZIONE Unità interna Tipo di condotto A uso esclusivo del personale tecnico autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Εσωτερική μονάδα Τύπος αγωγού Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό MANUAL DE INSTALAÇÃO Unidade interior Tipo conduta Somente para o pessoal do serviço técnico autorizado РУКОВОДСТВО ПО УСТАНОВКЕ Внутренний мод...

Страница 2: ...e display range 0 1 to 3 8 MPa Charging hose To increase pressure resistance the hose material and base size were changed Vacuum pump A conventional vacuum pump can be used by installing a vacuum pump adapter Gas leakage detector Special gas leakage detector for HFC refrigerant R410A 1 SAFETY PRECAUTIONS Be sure to read this Manual thoroughly before installation The warnings and precautions indica...

Страница 3: ...ise the expansion valve or capillary tube may become blocked with contaminants Improper pipe selection will degrade performance As an air conditioner using R410A in curs pressure higher than when using conventional refrigerant it is necessary to choose adequate materials Thicknesses of copper pipes used with R410A are as shown in the table Never use copper pipes thinner than those indicated in the...

Страница 4: ...nder 10 years old may approach the unit take preventive measures so that they cannot reach the unit 1 The inlet and outlet ports should not be obstructed the air should be able to blow all over the room 2 Leave the space required to service the air conditioner 3 Install the unit where connection to the outdoor unit is easy 4 Install the unit where the connection pipe can be easily installed 5 Inst...

Страница 5: ...r filter is not installed the heat exchanger may be clogged and its performance may decrease 4 4 Installing the drain hose CAUTION Install the drain hose in accordance with the instructions in this installation manual and keep the area warm enough to prevent condensation Problems with the piping may lead to water leaks Be sure to properly insulate the drain hose so that the water will not drip fro...

Страница 6: ...ed to provide a trap for the safety drain pipe If the safety drain pipe is connected to the main drain pipe make the connection below the trap on the main drain pipe Drain pipe main Drain pipe safety Unit Once installation is complete check the flow of the drain water 5 PIPE INSTALLATION WARNING During installation make sure that the refrigerant pipe is attached firmly before you run the compresso...

Страница 7: ...electric shock or fire Match the terminal block numbers and connection cable colors with those of the outdoor unit Erroneous wiring may cause burning of the electric parts Securely connect the connection cables to the terminal board In addition secure the cables with wiring holders Improper connections either in the wiring or at the ends of the wiring can cause a malfunction electric shock or fire...

Страница 8: ...oor units by attaching an earth ground cable Unit shall be grounded in compliance with the country or region s regulations CAUTION Be sure to refer to the above diagram for do correct field wiring Wrong wiring causes malfunction of the unit Check local electrical rules and also any specific wiring instructions or limitation 6 2 Connection cable preparation Keep the earth ground wire longer than th...

Страница 9: ...se connect the connector to the front case Screws SET BACK Front case back side Rear case Connector When remote controller cable is concealed 1 Conceal the remote controller cable 2 Pass the remote controller cable through the hole in the rear case and connect the remote controller cable to the remote controller terminal board specified in figure 3 Clamp the remote controller cable sheath with the...

Страница 10: ...R SET button for a few seconds until the setting value stops flashing If the setting value display changes or if is displayed when the flashing stops the setting value has not been set correctly An invalid setting value may have been selected for the indoor unit 6 Repeat steps 2 to 5 to perform additional settings Press the SET TEMP buttons and FAN button simultaneously again for more than 5 secon...

Страница 11: ... 1 Filter sign 2 Cooling room temperature correction 3 Heating room temperature correction 4 Auto restart 5 Indoor room temperature sensor switching function 6 External input control 7 Room temperature control switching 8 Indoor unit fan control for energy saving for cooling After completing the Function Setting be sure to turn off the power and turn it on again SETTING THE ROOM TEMPERATURE DETECT...

Страница 12: ...troller setting again NOTE When different indoor unit models are connected using the group control system some functions may no longer be available If the group control system contains multiple units that are operated simultaneously con nect and set the units as shown below Auto changeover operates under the same mode with model unit number 00 It should not be connected to any other Gr that is not...

Страница 13: ...ts free of any obstacles No cooling No heating After installation is completed has the proper operation and handling been explained to the user 11 TEST RUN CHECK ITEMS 1 Is operation of each button on the remote controller normal 2 Is the drain normal 3 Is there any abnormal noise and vibration during operation Do not operate the air conditioner in test run for a long time OPERATION METHOD For the...

Страница 14: ...le temp sensor error Indoor unit fan motor error Drain pump error Damper error Indoor unit error Outdoor unit main PCB model information error or communication error Inverter error Active filter error PFC circuit error Trip terminal L error Display PCB microcomputers communication error Discharge temp sensor error Compressor temp sensor error Outdoor unit Heat Ex liquid temp sensor error Outdoor t...

Страница 15: ...9379123143_IM indb 15 10 16 2017 08 55 11 ...

Отзывы: