NOTE

:  This manual describes how to install the air conditioner described above. Handling 

and installation shall only be done by professionals as outlined in this manual.

1. SAFETY PRECAUTIONS

•  Be sure to read this manual thoroughly before installation.
•  The warnings and precautions indicated in this manual contain important information 

pertaining to your safety. Be sure to observe them.

•  Hand this manual, together with the operating manual, to the customer. Request the 

customer to keep them on hand for future use, such as for relocating or repairing the 
unit.

 WARNING

Indicates a potentially or imminently hazardous situation 
which, if not avoided, could result in death or serious injury. 

 CAUTION

Indicates a potentially hazardous situation that may result in 
minor or moderate injury or damage to property.

 WARNING

•  The appliance shall be installed, operated and stored in a room with a 

fl

 oor area larger 

than X m².

Amount of refrigerant charge

M (kg)

Minimum room area

X (m

2

)

 1.22

-

1.22 < M 

 1.23

1.45

1.23 < M 

 1.50

2.15

1.50 < M 

 1.75

2.92

1.75 < M 

 2.0

3.82

2.0 < M 

 2.5

5.96

2.5 < M 

 3.0

8.59

3.0 < M 

 3.5

11.68

3.5 < M 

 4.0

15.26

 (IEC 

60335-2-40)

•  Installation of this product must be done by experienced service technicians or profes-

sional installers only in accordance with this manual. Installation by non-professional 
or improper installation of the product might cause serious accidents such as injury, 
water leakage, electric shock, or 

fi

 re. If the product is installed in disregard of the 

instructions in this manual, it will void the manufacturer’s warranty.

•  Do not turn on the power until all work has been completed. Turning on the power be-

fore the work is completed can cause serious accidents such as electric shock or 

fi

 re.

•  If refrigerant leaks when you are working, ventilate the area. If the leaking refrigerant 

is exposed to a direct 

fl

 ame, it may produce a toxic gas.

•  Installation must be performed in accordance with regulations, codes, or standards for 

electrical wiring and equipment in each country, region, or the installation place.

•  Do not use means to accelerate the defrosting process or to clean, other than those 

recommended by the manufacturer.

•  This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. Children should be supervised to ensure that they 
do not play with the appliance.

•  To avoid danger of suffocation, keep the plastic bag or thin 

fi

 lm used as the packaging 

material away from young children.

•  The appliance shall be stored in a room without continuously operating ignition 

sources (for example: open 

fl

 ames, an operating gas appliance or an operating 

electric heater).

•  Do not pierce or burn.
•  Be aware that refrigerants may not contain an odour.

AIR CONDITIONER
INDOOR UNIT (Duct type)

INSTALLATION MANUAL

PART No. 9381386215

[Original instructions] 

For authorized service personnel only.

Contents

1. SAFETY 

PRECAUTIONS ……………………………………………… 1

2. PRODUCT 

SPECIFICATION …………………………………………… 4

2.1. Installation tools …………………………………………………… 4
2.2. Accessories ………………………………………………………… 4
2.3. Pipe requirement …………………………………………………… 5
2.4. Electrical requirement ……………………………………………… 5
2.5. Optional parts ……………………………………………………… 5

3. INSTALLATION 

WORK ………………………………………………… 5

3.1. Selecting an installation location  ………………………………… 5
3.2. Installation dimension ……………………………………………… 6
3.3. Installing the unit …………………………………………………… 6
3.4. Intake duct connection  …………………………………………… 7
3.5. Drain installation …………………………………………………… 7
3.6. Pipe installation  …………………………………………………… 8
3.7. Fresh air intake 

……………………………………………………… 9

3.8. Electrical wiring  ………………………………………………… 10
3.9. Remote controller installation …………………………………… 11

4. OPTIONAL 

INSTALLATION 

WORK ………………………………… 11

4.1.  Optional kit installation  ………………………………………… 11
4.2. External input and output ……………………………………… 11
4.3. Remote sensor   ………………………………………………… 12

5. REMOTE 

CONTROL 

INSTALLATION ……………………………… 12

5.1. Group control …………………………………………………… 12
5.2. Multiple remote control  ………………………………………… 13
5.3. DIP switch 101 setting …………………………………………… 13

6. FUNCTION 

SETTING ………………………………………………… 13

6.1. Function details  ………………………………………………… 13
6.2. Static pressure …………………………………………………… 14

7. CHECK 

LIST …………………………………………………………… 15

8. TEST 

RUN ……………………………………………………………… 15

8.1. Check items ……………………………………………………… 15
8.2. Operation method  ……………………………………………… 15

9. FINISHING 

……………………………………………………………… 15

10. CUSTOMER GUIDANCE ……………………………………………… 15

11. ERROR CODES ……………………………………………………… 16

9381386215-01_IM.indb   1

9381386215-01_IM.indb   1

12/5/2018   2:57:35 PM

12/5/2018   2:57:35 PM

Содержание ARXG-KHTAP Series

Страница 1: ...lation must be performed in accordance with regulations codes or standards for electrical wiring and equipment in each country region or the installation place Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or ...

Страница 2: ...ance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall be performed only as recommended by the manufacturer 2 2 Work Prior ...

Страница 3: ...nce to electrical components shall include initial safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be con nected to the circuit until it is satisfactorily dealt with If the fault cannot be corrected immediately but it is necessary to continue operation an adequate temporary solution shall be used This shall be reporte...

Страница 4: ...ure 0 1 to 3 8 MPa 1 to 38 bar for low pressure Charge hose To increase pressure resistance the hose material and base size were changed R32 R410A Vacuum pump A conventional vacuum pump can be used by installing a vacuum pump adapter Use of a vacuum pump with a series motor is prohibited Gas leakage detector Special gas leakage detector for HFC refrigerant R410A or R32 Copper pipes It is necessary...

Страница 5: ...g such work with an insufficient number of people or with inadequate equip ment could result in dropping of the unit or personal injury CAUTION For installation details refer to the technical data 3 1 Selecting an installation location Decide the mounting position together with the customer as follows WARNING Install the indoor unit where is capable to support the weight of the unit Secure the uni...

Страница 6: ...ent could result in dropping of the unit or personal injury If the job is done with the panel frame only there is a risk that the unit will come loose Please take care When fastening the hangers make the bolt positions uniform CAUTION Confirm the directions of the air intake and outlet before installing the unit The unit takes in air from the evaporator side and expels it from the fan side 3 3 1 P...

Страница 7: ...pply Room Duct Field supply When connecting the duct perform duct insulation appropriate for the installing environment Inappropriate insulation work may cause condensation on the surface of the insulat ing material and may lead to condensation dripping 3 5 Drain installation CAUTION Install the drain hose in accordance with the instructions in this installation manual and keep the area warm enoug...

Страница 8: ...ing installation make sure that the refrigerant pipe is attached firmly before you run the compressor Do not operate the compressor under the condition of refrigerant piping not attached properly with 2 way or 3 way valve open This may cause abnormal pressure in the refrigeration cycle that leads to breakage and even injury During the pump down operation make sure that the compressor is turned off...

Страница 9: ...are nut cannot be tightened smoothly If the flare nut is forced to turn the threads will be damaged Do not remove the flare nut from the indoor unit pipe until immediately before connecting the connection pipe Do not use mineral oil on flared part Prevent mineral oil from getting into the system as this would reduce the lifetime of the units 1 Detach the caps and plugs from the pipes 2 Centering t...

Страница 10: ... ground cable to a gas pipe water pipe lightning rod or a telephone earth ground cable Improper earthing grounding may cause electric shocks Do not connect power supply cables to the transmission or remote control terminals as this will damage the product Never bundle the power supply cable and transmission cable together Bundling these cables together will cause miss operation When handling PCB s...

Страница 11: ...ternal in out PCB CN47 External out This air conditioner can be connected with the following optional kits For details on how to install optional parts refer to the installation manual included in each item Connector No Option type CN48 IR Receiver UTY LBT M CN8 Remote sensor UTY XSZX CN47 1 Connect wire UTY XWZXZG CN65 2 External input and output PCB UTY XCSX 1 For external output terminal settin...

Страница 12: ... is used The original connector should be insulated to ensure that it does not come into contact with other electrical circuitry Setting for room temperature correction When a remote sensor is connected set the function setting of indoor unit as indicated below Set Function Number 30 Room temperature control for cooling to 00 Set Function Number 31 Room temperature control for heating to 01 5 REMO...

Страница 13: ...on details Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room If the indication is not required select No indication 03 Factory setting Function Number Setting Value Setting Description 11 00 Standard 2500 hours 01 Long interval 4400 hours 02 Short interval 1250 hours 03 No indication Room temp...

Страница 14: ... outdoor unit is stopped the indoor unit fan operates intermittently at a very low speed 02 Enable or disable this function by remote controller setting When using a wired remote controller without Indoor unit fan control for energy saving for cooling function or when connecting a single split converter the setting cannot be made by using the remote controller Set to 00 or 01 To confirm if the rem...

Страница 15: ...unded Is the connection cable the specified thickness Are the inlets and outlets free of any obstacles After installation is completed has the proper operation and handling been explained to the user Operate the unit according to the operating manual provided and check that it is operating normally 8 TEST RUN 8 1 Check items Is operation of each button on the remote control unit normal Does each l...

Страница 16: ...ed remote controller error 4 1 Room temp sensor error 4 2 Indoor unit heat ex middle temp sensor error 4 4 Human sensor error 5 1 Indoor unit fan motor error 5 3 Drain pump error 5 7 Damper error 5 15 Indoor unit error 6 1 Outdoor unit reverse missing phase and wiring error Error display Wired remote controller Error code Description OPERATION lamp green TIMER lamp orange ECONOMY lamp green 6 2 Ou...

Отзывы: