![Fujitsu AOYG18LBCA Скачать руководство пользователя страница 111](http://html.mh-extra.com/html/fujitsu/aoyg18lbca/aoyg18lbca_technical-manual_2344273111.webp)
- 105 -
O
U
T
D
OOR UNIT
AOY
G
18-
54LB
9. Electrical characteristics
*1: Maximum current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate
devices complied to the regional standard.
*3: Limit voltage drop to less than 2%. Increase conductor size if voltage drop is 2% or more.
Model name
AOYG18LBCA
AOYG24LBCA
AOYG30LBTA
AOYG36LBTA
Power
supply
Voltage
V
230 ~
Frequency
Hz
50
Max operating current *1
A
13.5
18.5
17.0
20.0
Wiring
spec. *2
Circuit breaker
current
A
25
30
Power cable
mm
2
4.0
Connection
cable *3
mm
2
1.5 — 2.5
Limited
wiring
length
m
31
51
Model name
AOYG45LBTA
AOYG54LBTA
Power supply Voltage
V
230 ~
Frequency
Hz
50
Max operating current *1
A
22.5
23.5
Wiring spec.
*2
Circuit breaker current
A
30
Power cable
mm
2
6.0
Connection cable *3
mm
2
1.5 — 2.5
Limited wiring
length
m
51
Содержание AOYG18LBCA
Страница 7: ...Part 1 INDOOR UNIT DUCT TYPE ARYG18LHTBP ARYG24LHTBP ARYG30LHTBP ARYG36LHTBP ARYG45LHTBP ARYG54LHTBP ...
Страница 24: ... 18 DUCT TYPE ARYG18 54LHTBP 5 Wiring diagrams 5 1 Models ARYG18LHTBP and ARYG24LHTBP ...
Страница 25: ... 19 DUCT TYPE ARYG18 54LHTBP 5 2 Models ARYG30LHTBP ARYG36LHTBP ARYG45LHTBP and ARYG54LHTBP ...
Страница 77: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG18LBCA AOYG24LBCA AOYG30LBTA AOYG36LBTA AOYG45LBTA AOYG54LBTA ...
Страница 96: ... 90 OUTDOOR UNIT AOYG18 54LB 4 Wiring diagrams 4 1 Models AOYG18LBCA and AOYG24LBCA ...
Страница 97: ... 91 OUTDOOR UNIT AOYG18 54LB 4 2 Model AOYG30LBTA ...
Страница 98: ... 92 OUTDOOR UNIT AOYG18 54LB 4 3 Model AOYG36LBTA ...
Страница 99: ... 93 OUTDOOR UNIT AOYG18 54LB 4 4 Models AOYG45LBTA and AOYG54LBTA ...