- 110 -
O
U
T
D
OOR UNIT
AOY
G
12-
54LB
6-4. Model: AOYG30LBTA
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Pipe length (m)
5
7.5
10
20
30
40
50
He
igh
t
diff
er
en
ce
H
(m
)
Indoor unit is higher
than outdoor unit *1
30
-
-
-
-
0.908
0.894
0.876
20
-
-
-
0.935
0.923
0.909
0.891
10
-
-
0.968
0.951
0.938
0.924
0.906
7.5
-
0.982
0.972
0.954
0.942
0.928
0.909
5
0.992
0.992
0.976
0.958
0.946
0.932
0.913
0
1.000
1.000
0.983
0.966
0.954
0.939
0.920
Indoor unit is lower
than outdoor unit *2
-5
1.000
1.000
0.983
0.966
0.954
0.939
0.920
-7.5
-
1.000
0.983
0.966
0.954
0.939
0.920
-10
-
-
0.983
0.966
0.954
0.939
0.920
-20
-
-
-
0.966
0.954
0.939
0.920
-30
-
-
-
-
0.954
0.939
0.920
HEATING
Pipe length (m)
5
7.5
10
20
30
40
50
He
igh
t differ
ence H (m)
Indoor unit is higher
than outdoor unit *1
30
-
-
-
-
0.934
0.912
0.899
20
-
-
-
0.957
0.934
0.912
0.899
10
-
-
0.969
0.957
0.934
0.912
0.899
7.5
-
1.000
0.969
0.957
0.934
0.912
0.899
5
1.000
1.000
0.969
0.957
0.934
0.912
0.899
0
1.000
1.000
0.969
0.957
0.934
0.912
0.899
Indoor unit is lower
than outdoor unit *2
-5
0.995
0.995
0.964
0.952
0.930
0.907
0.895
-7.5
-
0.993
0.962
0.950
0.927
0.905
0.893
-10
-
-
0.959
0.947
0.925
0.903
0.890
-20
-
-
-
0.938
0.916
0.894
0.881
-30
-
-
-
-
0.906
0.885
0.872
Содержание AOYG12LBLA
Страница 26: ... 20 DUCT TYPE ARYG12 54LHTBP 5 Wiring diagrams 5 1 Models ARYG12LHTBP ARYG14LHTBP ARYG18LHTBP and ARYG24LHTBP ...
Страница 27: ... 21 DUCT TYPE ARYG12 54LHTBP 5 2 Models ARYG30LHTBP ARYG36LHTBP ARYG45LHTBP and ARYG54LHTBP ...
Страница 110: ... 104 OUTDOOR UNIT AOYG12 54LB 5 Wiring diagrams 5 1 Models AOYG12LBLA and AOYG14LBLA ...
Страница 111: ... 105 OUTDOOR UNIT AOYG12 54LB 5 2 Models AOYG18LBCA and AOYG24LBCA 5 3 Model AOYG30LBTA ...
Страница 112: ... 106 OUTDOOR UNIT AOYG12 54LB 5 4 Model AOYG36LBTA ...
Страница 113: ... 107 OUTDOOR UNIT AOYG12 54LB 5 5 Models AOYG45LBTA and AOYG54LBTA ...