background image

En-6

OPERATING MANUAL

Care and Cleaning

 

CAUTION

• Before cleaning the indoor unit, be sure to turn it off and all the power supply has been disconnected. 

• Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an 

effect on the proper working or performance of the air conditioner.

• Do not touch the aluminum 

¿

 ns of heat exchanger built-in the indoor unit to avoid personal injury when you  maintain the unit.

• Do not expose the indoor unit to liquid insecticides or hair sprays.

• Do not stand on slippery, uneven or unstable surfaces when you maintain the unit.

Daily care

When cleaning the indoor unit body, mind the following:

• Do not use water hotter than 40 °C.
• Do not use scouring cleanser, volatile solvents such as benzene or 

thinner.

• Wipe the unit gently by using soft cloth.

 Cleaning the intake grille

1

  Open the intake grille in direction of the arrow 

a

. While gently 

pressing the left and right mounting shafts of the intake grille 
outward 

b

, remove the intake grille in direction of the arrow 

c

.

a

a

b

c

b

c

2

  Wash the intake grille gently with water or wipe it gently with a 

soft cloth moisten with warm water.

 

Then wipe it with a dry and soft cloth.

3

  While holding the grille horizontal, set the left and right mounting 

shafts into the pillow blocks at the top of the panel 

a

. To latch 

each shaft properly, insert the shaft until it snaps.

 

Then close the intake grille 

b

.

a

a

b

b

4

  Press 4 places on the intake grille to close it completely.

  Cleaning the air 

¿

 lters

Mind that you have a periodical cleaning of the air 

¿

 lters to prevent 

reducing the operation ef

¿

 ciency of the product. 

Using of clogged air 

¿

 lter with dust will lower the product performance, 

and may cause air

À

 ow reduction or increase of operating noise. 

Clean the air 

¿

 lters once every 2 weeks under normal use.

1

  Open the intake grille.

 (Refer 

to 

a

 of step 1 in “Cleaning the intake grille”.)

2

  While holding the intake grille with your hand, pull up the handle 

of the 

¿

 lter in direction of the arrow and release the 2 claws 

b

.

Then pull the 

¿

 lter out with gently sliding it downward 

c

.

a

b

b

a

c

3

  Filter holder and air cleaning 

¿

 lter are attached on the rear side 

of the air 

¿

 lter. Remove them from the air 

¿

 lter by unlatching each 

corner of the 

¿

 lter holder 

d

.

d

d

d

d

4

  Remove dust by using a vacuum cleaner or by washing the 

¿

 lter.

When you wash the 

¿

 lter, use neutral household detergent and 

warm water.
After rinse the 

¿

 lter well, dry it throughly in a shaded place before 

you reinstall it.

5

  Attach the air cleaning 

¿

 lter and the 

¿

 lter holder to each air 

¿

 lter.

6

  Attach the air 

¿

 lter with aligning both side of the 

¿

 lter with the front 

panel, and push in the 

¿

 lter fully.

Note:

 

Make sure that 2 claws are 

¿

 rmly snapped to the guide holes on 

the panel.

7

  Close the intake grille 

¿

 rmly.

(Refer to step 4 in “Cleaning the intake grille”.)

9333003047_OM.indb   6

6/28/2013   11:46:17 AM

Содержание aoyg09lmca

Страница 1: ...ot install the unit in area lled with mineral oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use inÀammable gases near the unit Do not expose yourself directly to the cooling airÀow for many hours Do not...

Страница 2: ...irÀow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 6 Drain hose 7 Remote control signal receiver CAUTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous Àuorescent...

Страница 3: ...If the remote control range noticeably got shorten replace the batteries and press RESET button You can quickly start the operation with following 3 steps Remote Controller Overview and Operations 1 START STOP button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for...

Страница 4: ...n the unit is rotating at very low speed or stopping In FAN mode either of swing direction 1 l 3 or 4 l 7 is performed in accordance with the vertical airÀow direction previously set before you start the SWING operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airÀow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asle...

Страница 5: ...d it could reduce the operating performance of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate brieÀy maximum of 15 minutes OPERATION indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after th...

Страница 6: ...ocks at the top of the panel a To latch each shaft properly insert the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air lters Mind that you have a periodical cleaning of the air lters to prevent reducing the operation ef ciency of the product Using of clogged air lter with dust will lower the product performan...

Страница 7: ...amage 4 Rinse the lter well with water Àow 5 Dry the lter throughly in shaded place 6 Reinstall the ion deodorization lter to the indoor unit Replace the lter once every 3 years under normal use After extended non use of the unit If you have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts throughly before you perform normal operation...

Страница 8: ...e automatic defrosting operation while the OPERATION indicator is Àashing 5 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airÀow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring opera...

Отзывы: