background image

En-3

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

 

CAUTION

• To prevent malfunction or damage of the remote controller:

 

- Place remote controller at where will not be exposed to 

direct sunlight or excessive heat.

 

- Remove batteries if the product is not going to be used for 

an extended period.

 

- Exhausted batteries must be removed immediately, and 

be disposed according to the local laws and regulations of 
your region.

• If leaking battery 

À

 uid comes in contact with your skin, eyes, 

or mouth, immediately rinse with plenty of clean water, and 
consult your physician.

• Obstacles such as a curtain or wall between the remote 

controller and the indoor unit may affect the appropriate 
signal transmission.

• Do not apply strong shocks to the remote controller.

• Do not pour water on the remote controller.

• Do not attempt to recharge dry batteries.

Battery (R03/LR03/AAA × 2) loading and remote controller preparation

1

4

2

3

5
7

6

5

    Press CLOCK ADJUST button to start clock setting.

6

    Set the time by pressing SELECT button.

Each time you press the button, the value increases or 
decreases 1 minute. With pressing and holding the button, the 
value increasesor decreases 10 minutes.

7

    Press the CLOCK ADJUST button again to complete the clock 

setting.

Notes:

•  Use speci

¿

 ed type of battery only.

•  Do not use new battery and used battery together.
• Batteries can be used about 1 year in ordinary use.
•  If the remote control range noticeably got shorten, replace the 

batteries, and press RESET button.

You can quickly start the operation with following 3 steps:

Remote Controller Overview and Operations

1 START/STOP 

button

2 MODE 

button

Switches operation mode in following order.

AUTO  

COOL  

DRY  

FAN  

HEAT

Notes in HEAT mode:

• At the beginning of the operation, the indoor unit operates at very 

low fan speed for about 3–5 minutes for preparation, and then 
switches to the selected fan speed.

• Automatic defrosting operation overrides the heating operation when 

it is necessary.

Note in COOL mode:

Indoor unit fan may stop from time to time to perform indoor-unit-
fan control for energy saving that enables power-saving operation by 
stopping the rotation of the indoor unit fan when the outdoor unit is 
stopped.

(continued)

In initial setting, this function is activated.
To inactivate the function, consult the installer or authorized service 
personnel.

Even if the setting is changed, if the fan speed is set to “AUTO” in 
COOL or DRY mode, this function still works to suppress the diffusion 
of circulated indoor humidity.

3  

SET TEMP. (temperature) buttons

Set desired temperature. 
In COOL/DRY mode, the value needs to be set at lower temperature 
than current room temperature, and in HEAT mode, the value needs 
to be set at higher temperature than current room temperature.
Otherwise, corresponding operation mode does not start to work.

Temperature setting range

AUTO/COOL/DRY

18–30 °C

HEAT

16–30 °C

*:Temperature control is not available in FAN mode.

18

15

16

14

19

2

9

10

13

8

3

11

12

1

5

6

4

7

17

9333003047_OM.indb   3

6/28/2013   11:46:15 AM

Содержание aoyg09lmca

Страница 1: ...ot install the unit in area lled with mineral oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use inÀammable gases near the unit Do not expose yourself directly to the cooling airÀow for many hours Do not...

Страница 2: ...irÀow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 6 Drain hose 7 Remote control signal receiver CAUTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous Àuorescent...

Страница 3: ...If the remote control range noticeably got shorten replace the batteries and press RESET button You can quickly start the operation with following 3 steps Remote Controller Overview and Operations 1 START STOP button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for...

Страница 4: ...n the unit is rotating at very low speed or stopping In FAN mode either of swing direction 1 l 3 or 4 l 7 is performed in accordance with the vertical airÀow direction previously set before you start the SWING operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airÀow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asle...

Страница 5: ...d it could reduce the operating performance of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate brieÀy maximum of 15 minutes OPERATION indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after th...

Страница 6: ...ocks at the top of the panel a To latch each shaft properly insert the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air lters Mind that you have a periodical cleaning of the air lters to prevent reducing the operation ef ciency of the product Using of clogged air lter with dust will lower the product performan...

Страница 7: ...amage 4 Rinse the lter well with water Àow 5 Dry the lter throughly in shaded place 6 Reinstall the ion deodorization lter to the indoor unit Replace the lter once every 3 years under normal use After extended non use of the unit If you have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts throughly before you perform normal operation...

Страница 8: ...e automatic defrosting operation while the OPERATION indicator is Àashing 5 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airÀow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring opera...

Отзывы: