background image

En-5

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

Timer Operation

Note for timer settings:

Any interruption of the power supply, such as a blackout or cutting off of a circuit breaker, makes the set internal clock go wrong.
In such a case, the TIMER indicator on the indoor unit blinks, and you need to readjust the setting.

ON timer or OFF timer

1

  Turn on the indoor unit by pressing the START/STOP button.

OPERATION indicator on the indoor unit turns on.
If the indoor unit is already operating, skip this step.

2

  Press the ON timer button or the OFF timer button.

Clock indicator on the remote controller display starts blinking,
and TIMER indicator on the indoor unit turns on.

3

  Adjust the time by pressing the SELECT button within about 5 

seconds, while the clock indicator is blinking.
(About 5 seconds later, the remote controller display returns to 
standby screen.)

To cancel the timer and return to the normal operation, press the 
CANCEL button.
To redo the timer setting, perform step 2 and 3.

Program timer (combined use of the ON timer and the OFF timer)

You can set an integrated ON–OFF or OFF–ON timer.
Either of the timer whose con

¿

 gured starting time is closer to the 

current time works 

¿

 rst, and the order of timer operation is displayed 

as follows:

Timer

Indicator on remote controller display

ON–OFF timer

OFF–ON timer

The timer that is set later starts counting down after the counting 
down of the preceding timer is 

¿

 nished.

Notes:

• If you change the setting value for the timer after the program timer 

is set, the counting down of the timer will be reset at that moment.

•  Time setting for each combination should be within a span of 24 hours.

SLEEP timer

1

  Press the SLEEP timer button to activate the SLEEP timer.

OPERATION indicator and TIMER indicator on the indoor unit 
turns on.

2

  Adjust the time by pressing the SELECT button within about 5 

seconds, while the clock indicator is blinking.
(About 5 seconds later, the remote controller display returns to 
standby screen.)
Each time you press the button, the time changes as follows:

9.0

7.0

5.0

3.0

2.0

1.0

0.5

hours

(30 min.)

To repeat the timer, press the SLEEP timer button when 

 

indicator is not displayed on the remote controller display.

To help you to fall asleep comfortably and prevent excessive warming 
or cooling in sleep, the SLEEP timer controls the temperature setting 
automatically in accordance with the set time shown as follows. The 
air conditioner completely turns off after the set time has elapsed.

In HEAT mode

Set
temperature

Set time

1 hour

Set time

1 hour

1.5 hour

30 min.

1 °C 2 °C 3 °C 4 °C

2 °C

1 °C

In COOL or DRY mode

General Informations on Operation

 Automatic defrosting operation

When outdoor temperature is very low with high humidity, frost 
may form on the outdoor unit during the heating operation, and 
it could reduce the operating performance of the product. 
For frost protection, a microcomputer-controlled automatic 
defrost function is equipped in this air conditioner. 
If frost forms, the air conditioner will temporarily stop, and 
defrost circuit will operate brie

À

 y (maximum of 15 minutes.)

OPERATION indicator on the indoor unit blinks during this 
operation. 
If frost forms on the outdoor unit after the heating operation, the 
outdoor unit will stop automatically after it operates for a few 
minutes. Then the automatic defrosting operation starts.

 Auto-restart function

In event of power interruption such as a blackout, the air 
conditioner stops once. But it restarts automatically and 
performs previous operation when the power supply is resumed.

If any power interruption occurs after the timer is set, counting 
down of the timer will be reset. 
After the power supply is resumed, the TIMER indicator on the 
indoor unit blinks to notify you that there has been a timer fault. 
In such a case, reset the timer for your opportune time.

Malfunctions caused by other electrical devices:

Use of other electrical appliances such as an electric shaver or 
nearby use of a wireless radio transmitter may cause the malfunction 
of the air conditioner. 
If you encounter such a malfunction, turn off the circuit breaker once. 
Then turn it on again, and resume operation by using the remote 
controller.

Multi-type air conditioner

This indoor unit can be connected to a multi-type outdoor unit, 
and used as a multy-type air conditioner that allows multiple 
indoor units to be operated in multiple locations.
The indoor units may be operated simultaneously, in accor-
dance with their respective output.

Simultaneous use of multiple indoor units

• If 2 or more indoor units are operated simultaneously, the 

heating and cooling ef

¿

 ciency will be less than the ef

¿

 ciency in 

single use of the indoor unit.
Combined use of other auxiliary heating or cooling apparatus 
is recommended.

• Following combinations cannot be performed when multiple 

indoor units are operated:

 

- HEAT mode and COOL mode (or DRY mode)

 

- HEAT mode and FAN mode

The indoor unit operated afterward stops and the OPERA-
TION indicator 

À

 ashes.

•  The operating mode (HEAT, COOL, and DRY) of the outdoor 

unit is determined by the operating mode of the indoor unit that 
is operated 

¿

 rst. If the indoor unit is started in FAN mode, the 

operating mode of the outdoor unit cannot be determined.
For example, if indoor unit (A) is started in FAN mode and then 
indoor unit (B) is operated in HEAT mode, indoor unit (A) will 
temporarily start operation in FAN mode but when indoor unit 
(B) started operation in HEAT mode, the OPERATION indicator 
(green) on the indoor unit (A) will begin to blink (1 second on, 
1 second off) and go into standby mode. Indoor unit (B) will 
continue to operate in HEAT mode.

• In HEAT mode, the top of the indoor unit may become warm 

by emitted heat of circulated coolant through the indoor unit, 
even if the unit operation is stopped. This is not a malfunction.

9333003047_OM.indb   5

6/28/2013   11:46:17 AM

Содержание aoyg09lmca

Страница 1: ...ot install the unit in area lled with mineral oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use inÀammable gases near the unit Do not expose yourself directly to the cooling airÀow for many hours Do not...

Страница 2: ...irÀow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 6 Drain hose 7 Remote control signal receiver CAUTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous Àuorescent...

Страница 3: ...If the remote control range noticeably got shorten replace the batteries and press RESET button You can quickly start the operation with following 3 steps Remote Controller Overview and Operations 1 START STOP button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for...

Страница 4: ...n the unit is rotating at very low speed or stopping In FAN mode either of swing direction 1 l 3 or 4 l 7 is performed in accordance with the vertical airÀow direction previously set before you start the SWING operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airÀow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asle...

Страница 5: ...d it could reduce the operating performance of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate brieÀy maximum of 15 minutes OPERATION indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after th...

Страница 6: ...ocks at the top of the panel a To latch each shaft properly insert the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air lters Mind that you have a periodical cleaning of the air lters to prevent reducing the operation ef ciency of the product Using of clogged air lter with dust will lower the product performan...

Страница 7: ...amage 4 Rinse the lter well with water Àow 5 Dry the lter throughly in shaded place 6 Reinstall the ion deodorization lter to the indoor unit Replace the lter once every 3 years under normal use After extended non use of the unit If you have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts throughly before you perform normal operation...

Страница 8: ...e automatic defrosting operation while the OPERATION indicator is Àashing 5 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airÀow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring opera...

Отзывы: