6. Capacity compensation rate for pipe length and height
difference
Height difference H
Indoor unit is higher than outdoor unit
*
1
Indoor unit is lower than outdoor unit
*
2
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
H
H
6-1. Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA,
and AOYG14KGCA
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Pipe length (m)
5
7.5
10
15
20
Height difference H (m)
Indoor unit is higher than
outdoor unit *1
15
—
—
—
0.858
0.868
10
—
—
0.929
0.872
0.882
7.5
—
0.960
0.933
0.876
0.885
5
0.992
0.964
0.937
0.879
0.889
0
1.000
0.972
0.944
0.887
0.896
Indoor unit is lower than
outdoor unit *2
-5
1.000
0.972
0.944
0.887
0.896
-7.5
—
0.972
0.944
0.887
0.896
-10
—
—
0.944
0.887
0.896
-15
—
—
—
0.887
0.896
HEATING
Pipe length (m)
5
7.5
10
15
20
Height difference H (m)
Indoor unit is higher than
outdoor unit *1
15
—
—
—
0.896
0.879
10
—
—
0.968
0.890
0.879
7.5
—
0.994
0.968
0.896
0.879
5
1.000
0.994
0.968
0.896
0.879
0
1.000
0.994
0.968
0.896
0.879
Indoor unit is lower than
outdoor unit *2
-5
0.995
0.989
0.963
0.891
0.875
-7.5
—
0.987
0.961
0.889
0.873
-10
—
—
0.959
0.887
0.871
-15
—
—
—
0.878
0.862
- 51 -
OUTDOOR UNIT
AOYG07-14KGCA
Содержание AOYG07KGCA
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA ...
Страница 10: ...3 Wiring diagrams 3 1 Models ASYG07KGTA ASYG09KGTA ASYG12KGTA and ASYG14KGTA 6 WALL MOUNTED ASYG07 14KGTA ...
Страница 47: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA ...
Страница 54: ...5 Wiring diagrams 5 1 Models AOYG07KGCA AOYG09KGCA AOYG12KGCA and AOYG14KGCA 50 OUTDOOR UNIT AOYG07 14KGCA ...