Part 2.  OUTDOOR UNIT................................................................. 43

  1. Specifications..........................................................................................44
  2. Dimensions..............................................................................................45

2-1. Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA...... 45

  3. Installation space ....................................................................................46

3-1. Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA...... 46

  4. Refrigerant circuit ...................................................................................49

4-1. Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA...... 49

  5. Wiring diagrams ......................................................................................50

5-1. Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA...... 50

  6. Capacity compensation rate for pipe length and height difference.... 51

6-1. Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA...... 51

  7. Additional charge calculation ................................................................52

7-1. Models: AOYG07KGCA and AOYG09KGCA ........................................................... 52
7-2. Models: AOYG12KGCA and AOYG14KGCA ........................................................... 52

  8. Airflow ......................................................................................................53

8-1. Model: AOYG07KGCA.............................................................................................. 53
8-2. Model: AOYG09KGCA.............................................................................................. 53
8-3. Model: AOYG12KGCA.............................................................................................. 53
8-4. Model: AOYG14KGCA.............................................................................................. 54

  9. Operation noise (sound pressure).........................................................55

9-1. Noise level curve....................................................................................................... 55
9-2. Sound level check point ............................................................................................ 57

10. Electrical characteristics ........................................................................58
11. Safety devices .........................................................................................59
12. Accessories .............................................................................................60

12-1.Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA, and AOYG14KGCA..... 60

CONTENTS (continued)

Содержание AOYG07KGCA

Страница 1: ...AIR CONDITIONER Wall mounted type DESIGN TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_03 2017 12 15 ...

Страница 2: ...please check with our authorized dealer Trademarks FGLair is trademark of Fujitsu General Limited in the United States other countries or both Google Play is trademark of Google Inc App Store is a service mark of Apple Inc registered in the U S and other countries Copyright 2017 Fujitsu General Limited All rights reserved ...

Страница 3: ... 1 Noise level curve 16 6 2 Sound level check point 18 7 Safety devices 19 8 External input and output 20 8 1 External input 21 8 2 External output 22 8 3 Combination of external input and output 23 8 4 Details of function 25 9 Group connection 30 10 Remote controller 31 10 1 Wireless remote controller 31 11 Function settings 33 11 1 Function settings by using remote controller 33 11 2 Custom code...

Страница 4: ...compensation rate for pipe length and height difference 51 6 1 Models AOYG07KGCA AOYG09KGCA AOYG12KGCA and AOYG14KGCA 51 7 Additional charge calculation 52 7 1 Models AOYG07KGCA and AOYG09KGCA 52 7 2 Models AOYG12KGCA and AOYG14KGCA 52 8 Airflow 53 8 1 Model AOYG07KGCA 53 8 2 Model AOYG09KGCA 53 8 3 Model AOYG12KGCA 53 8 4 Model AOYG14KGCA 54 9 Operation noise sound pressure 55 9 1 Noise level cur...

Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA ...

Страница 6: ...34 35 36 LOW 29 29 30 30 QUIET 19 19 19 20 Heating HIGH 41 42 42 44 MED 35 36 38 39 LOW 31 31 33 33 QUIET 21 21 21 24 Heat exchanger type Dimensions H W D mm Main1 210 670 26 6 Main2 112 670 20 Main1 210 670 26 6 Main2 112 670 20 Sub 84 670 13 3 Fin pitch Man1 1 2 Main2 1 1 Man1 1 2 Main2 1 1 Sub 1 4 Rows Stages Main1 2 10 Main2 2 7 Main1 2 10 Main2 2 7 Sub 1 4 Pipe type Copper tube Fin type Alumi...

Страница 7: ... 2 5 35 C 3 4 35 C 4 2 35 C Heating Average 2 3 10 C 2 4 10 C 2 5 10 C 4 0 10 C SEER Cooling kWh kWh 8 52 8 52 8 51 7 11 SCOP Heating Average 5 12 5 11 5 10 4 31 Annual energy consumption QCE kWh a 82 103 140 207 QHE Average 628 658 685 1 298 Sound power level Cooling HIGH dB A 54 55 56 57 Heating 56 57 58 59 3 WALL MOUNTED ASYG07 14KGTA ...

Страница 8: ...ASYG07KGTA ASYG09KGTA ASYG12KGTA and ASYG14KGTA Unit mm 834 834 Outline of indoor unit 327 273 273 54 215 3 0 270 270 43 43 9 5 220 for pipe inlet Ø65 for pipe inlet Ø65 182 182 356 346 48 84 63 63 4 WALL MOUNTED ASYG07 14KGTA ...

Страница 9: ...ion space for product safety Unit mm Wall hook bracket Outline of the indoor unit 50 or more 67 or more The flare connection part should be installed outdoors 40 or more 70 or more 107 or more 1 500 or more 1 800 or more 183 or more 5 WALL MOUNTED ASYG07 14KGTA ...

Страница 10: ...3 Wiring diagrams 3 1 Models ASYG07KGTA ASYG09KGTA ASYG12KGTA and ASYG14KGTA 6 WALL MOUNTED ASYG07 14KGTA ...

Страница 11: ... 2 55 0 18 3 13 2 65 0 19 3 27 2 66 0 18 3 41 2 72 0 18 3 61 2 78 0 17 3 87 2 91 0 17 10 2 71 2 40 0 27 2 92 2 47 0 26 3 08 2 56 0 26 3 22 2 57 0 26 3 35 2 63 0 25 3 55 2 69 0 25 3 81 2 82 0 24 15 2 65 2 44 0 35 2 86 2 52 0 34 3 02 2 61 0 34 3 15 2 62 0 33 3 28 2 68 0 33 3 48 2 74 0 32 3 73 2 87 0 32 20 2 64 2 43 0 42 2 85 2 50 0 41 3 01 2 59 0 41 3 14 2 60 0 40 3 27 2 66 0 40 3 47 2 72 0 39 3 72 ...

Страница 12: ... 4 63 3 31 0 42 4 96 3 41 0 43 15 3 44 2 88 0 51 3 72 2 99 0 53 3 91 3 05 0 50 4 11 3 13 0 51 4 21 3 18 0 52 4 55 3 28 0 51 4 88 3 37 0 53 20 3 36 2 83 0 60 3 63 2 94 0 62 3 82 3 01 0 59 4 02 3 09 0 60 4 11 3 13 0 61 4 45 3 23 0 60 4 77 3 32 0 62 25 3 26 2 78 0 68 3 53 2 89 0 71 3 72 2 95 0 67 3 90 3 03 0 68 3 99 3 07 0 69 4 32 3 17 0 68 4 63 3 26 0 71 30 3 15 2 72 0 76 3 41 2 83 0 79 3 59 2 89 0 ...

Страница 13: ...1 52 5 37 1 55 5 35 1 58 20 15 5 75 1 36 5 75 1 34 5 58 1 35 5 46 1 34 5 31 1 36 24 18 5 91 1 29 5 91 1 27 5 74 1 28 5 61 1 27 5 46 1 29 Model ASYG12KGTA AFR m3 h 770 Indoor temperature 16 18 20 22 24 Outdoor temperature CDB CWB TC IP TC IP TC IP TC IP TC IP kW kW kW kW kW 15 16 3 40 1 39 3 39 1 36 3 36 1 36 3 34 1 37 3 30 1 40 10 11 4 02 1 41 3 93 1 43 3 83 1 46 3 72 1 48 3 60 1 52 5 7 4 60 1 51 ...

Страница 14: ...p view Vertical airflow direction louver Up Horizontal airflow direction louver Left Right 2 0 2 0 1 0 1 0 0 5 0 5 Unit m s m m 3 2 1 0 1 2 3 0 1 2 3 4 5 6 7 8 9 10 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center m m 3 2 1 0 0 1 2 3 4 5 6 7 8 9 10 Unit m s 2 0 0 5 1 0 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Cent...

Страница 15: ...direction louver Up Horizontal airflow direction louver Left Right 1 0 1 0 0 5 0 5 2 0 2 0 Unit m s m m 3 2 1 0 1 2 3 0 1 2 3 4 5 6 7 8 9 10 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 2 0 0 5 1 0 m m 3 2 1 0 0 1 2 3 4 5 6 7 8 9 10 Unit m s Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 0 5 0 5 2 0 1 0 m m 3...

Страница 16: ... 181 CFM 383 MED m3 h 540 l s 150 CFM 318 LOW m3 h 430 l s 119 CFM 253 QUIET m3 h 270 l s 75 CFM 159 Heating Fan speed Airflow HIGH m3 h 720 l s 200 CFM 424 MED m3 h 580 l s 161 CFM 341 LOW m3 h 460 l s 128 CFM 271 QUIET m3 h 330 l s 92 CFM 194 12 WALL MOUNTED ASYG07 14KGTA ...

Страница 17: ...FM 412 MED m3 h 560 l s 156 CFM 330 LOW m3 h 430 l s 119 CFM 253 QUIET m3 h 270 l s 75 CFM 159 Heating Fan speed Airflow HIGH m3 h 750 l s 208 CFM 441 MED m3 h 610 l s 169 CFM 359 LOW m3 h 470 l s 131 CFM 277 QUIET m3 h 330 l s 92 CFM 194 13 WALL MOUNTED ASYG07 14KGTA ...

Страница 18: ...FM 412 MED m3 h 560 l s 156 CFM 330 LOW m3 h 430 l s 119 CFM 253 QUIET m3 h 250 l s 69 CFM 147 Heating Fan speed Airflow HIGH m3 h 770 l s 214 CFM 453 MED m3 h 640 l s 178 CFM 377 LOW m3 h 520 l s 144 CFM 306 QUIET m3 h 310 l s 86 CFM 182 14 WALL MOUNTED ASYG07 14KGTA ...

Страница 19: ...FM 453 MED m3 h 600 l s 167 CFM 353 LOW m3 h 450 l s 125 CFM 265 QUIET m3 h 280 l s 78 CFM 165 Heating Fan speed Airflow HIGH m3 h 800 l s 222 CFM 471 MED m3 h 660 l s 183 CFM 388 LOW m3 h 520 l s 144 CFM 306 QUIET m3 h 340 l s 94 CFM 200 15 WALL MOUNTED ASYG07 14KGTA ...

Страница 20: ... 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Model ASYG09KGTA Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure...

Страница 21: ...000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Model ASYG14KGTA Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar ...

Страница 22: ...6 2 Sound level check point 0 8 m 1 m Microphone Microphone NOTE Detailed shape of the actual indoor unit might be slightly different from the one illustrated above 18 WALL MOUNTED ASYG07 14KGTA ...

Страница 23: ...vate More than 85 C Fan motor speed down Reset 85 C or less Fan motor speed recover Type of protection Protection form Model ASYG12KGTA ASYG14KGTA Circuit protection Current fuse PCB 250 V 3 15 A Fan motor protection Power IC thermal shutdown protection Activate 125 25 C Fan motor stop Reset 110 25 20 C Fan motor restart PCB Printed Circuit Board 19 WALL MOUNTED ASYG07 14KGTA ...

Страница 24: ...CB CN6 PCB External input External output Connector Input select Input signal External input and output UTY XCSXZ2 Operation Stop CN313 CN314 Dry contact Apply voltage Edge Pulse Forced stop Forced thermostat off CN313 Edge Operation status CN310 Error status CN311 Indoor unit fan operation status CN312 20 WALL MOUNTED ASYG07 14KGTA ...

Страница 25: ...ypes of connectors according to the application Both types of con nectors cannot be used simultaneously Dry contact In case of internal power supply set the slide switch of SW301 to NON VOL side 1 2 3 Input 1 PCB Connected unit 1 2 3 Input 2 Connector CN313 Connector CN314 1 The switches can be used on the following condition DC 12 V to 24 V 1 mA to 15 mA Apply voltage In case of external power su...

Страница 26: ...her components are connected directly Example Function setting 60 is set to 00 1 2 Connector CN310 LED 1 Operation status PCB Resistor Connected unit 1 2 Connector CN311 LED 2 Error status Resistor 1 2 Connector CN312 LED 3 Indoor unit fan operation status Resistor When connecting with a device equipped with a power supply Example Function setting 60 is set to 00 1 2 Connected device 1 Connector C...

Страница 27: ... 10 C Forced Thermostat OFF Not available Edge 11 60 11 D Forced Thermostat OFF Not available Edge Mode Function setting External input and output PCB Rotary SW External output External input and output PCB CN310 CN311 CN312 0 1 60 00 1 Operation Stop Error status Indoor unit fan operation status 0 2 60 00 2 Error status Indoor unit fan operation status Not available 1 8 60 01 to 60 08 3 9 A Setti...

Страница 28: ...output PCB The input signal type can be selected Signal type edge or pulse can be switched by the DIP switch SW302 on the External input and output PCB Edge Pulse The width of pulse must be longer than 200 msec 24 WALL MOUNTED ASYG07 14KGTA ...

Страница 29: ...top Operation Stop Remote controller On Off Indoor unit On CN313 In the case of Pulse input Function setting Rotary SW on External input and output PCB External input Input signal Command 46 00 60 00 1 External input and output PCB CN313 Pulse Operation CN314 Pulse Stop On On Off Operation Stop Remote controller On Off Indoor unit CN313 CN314 NOTES The last command has priority The indoor units wi...

Страница 30: ...ion setting Rotary SW on External input and output PCB External input Input signal Command 46 02 60 00 1 External input and output PCB CN313 Pulse Forced stop CN314 Pulse Normal On Off Operation Stop Remote controller On Off Forced stop Normal CN313 CN314 On On On Indoorunit NOTES When the forced stop is triggered indoor unit stops and Operation Stop operation by the remote controller is restricte...

Страница 31: ...mote contoller On On Off In the case of Pulse input Function setting Rotary SW on External input and output PCB External input Input signal Command 46 03 60 00 1 External input and output PCB CN313 Pulse Operation CN314 Pulse Stop R C disabled On On Off Operation Stop Remote controller On Off Indoor unit CN313 CN314 R C disabled Off On NOTE When Operation Stop mode 2 function is used with forming ...

Страница 32: ...SW on External input and output PCB External input Input signal Command 60 00 2 60 09 B 60 10 C External input and output PCB CN313 Off On Thermostat off On Off Normal operation On Off On Off Compressor Room temp Set temp Input 28 WALL MOUNTED ASYG07 14KGTA ...

Страница 33: ...rnal input and output PCB CN311 Off On Error On Off Normal The output is ON when an error is generated for the indoor unit Error Normal On Off CN310 312 Indoor unit Indoor unit fan operation status Function setting Rotary SW on External input and output PCB External output Output signal Command 60 00 1 External input and output PCB CN312 Off On Fan run On Off Fan stop Output signal Condition On Th...

Страница 34: ...s Function setting Addresses will be automatically set when initially starting up this unit In such a case do not change the remote controller address for the indoor unit and keep it at the initial set ting of 00 Only set addresses manually when using different numbers for addresses Set the R C address of each indoor unit using the function setting Refer to Remote con troller address setting in Co...

Страница 35: ...ECONOMY button NOTE Functions may differ by type of the indoor unit For details refer to the operation manual Display panel Mode indicator ENERGY SAVING mode indicator LOW NOISE mode indicator Turns on when the SENSOR button is operated Clock and Timer indicator SEND indicator Temperature indicator Fan speed indicator Swing indicator Transmit indicator To facilitate explanation the accompanying il...

Страница 36: ...iew Side view 205 17 61 Size H W D mm 205 61 17 Weight g 122 without batteries Holder Unit mm 48 5 5 5 26 2 69 3 6 5 Front View Side View Bottom View Ø 3 5 Hole 150 106 8 Hole 3 5 2 R Size H W D mm 150 69 3 26 2 Weight g 27 32 WALL MOUNTED ASYG07 14KGTA ...

Страница 37: ...utdoor unit has been finished After reconfirming the items listed above connect the power supply of the indoor unit NOTES Settings will not be changed if invalid numbers or setting values are selected When optional wired remote controller is used refer to the installation manual enclosed with the remote controller Entering function setting mode While pressing the POWERFUL button and TEMP button si...

Страница 38: ...not become active unless the power supply is disconnected and then reconnect ed NOTES The air conditioner custom code is set to prior to shipment If you do not know the air conditioner custom code setting try each of the custom codes until you find the code that operates the air conditioner 34 WALL MOUNTED ASYG07 14KGTA ...

Страница 39: ... 60 Switching functions for external output terminal 1 Remote controller address setting NOTE Because this setting is normally done automatically when 2 wire type wired remote con troller is installed setting is unnecessary Multiple indoor units can be operated by using one wired remote controller Set the unit number of each indoor unit Function number Setting value Setting description Factory set...

Страница 40: ... the installed environment correction of the room temperature sensor may be re quired Select the appropriate control setting according to the installed environment The temperature correction values show the difference from the Standard setting 00 manufac turer s recommended value Function number Setting value Setting description Factory setting 30 For cooling 31 For heating 00 Standard setting 01 ...

Страница 41: ...C 14 2 5 C 15 3 0 C 16 3 5 C 17 4 0 C 5 Auto restart Enables or disables automatic restart after a power interruption Function number Setting value Setting description Factory setting 40 00 Enable 01 Disable NOTE Auto restart is an emergency function such as for power outage etc Do not attempt to use this function in normal operation Be sure to operate the unit by remote controller or external dev...

Страница 42: ...ion number Setting value Setting description Factory setting 48 00 Both 01 Wired remote controller 10 Indoor unit fan control for energy saving for cooling Enables or disables the power saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation Function number Setting value Setting description Factory setting 49 00 Disable 01 Enable 02 Rem...

Страница 43: ...f the external output terminal can be switched For details refer to External input and output Function number Setting value Setting description Factory setting 60 00 Operation status 09 Error status 10 Indoor unit fan operation status 39 WALL MOUNTED ASYG07 14KGTA ...

Страница 44: ...to operate for the air conditioner 1 Press the START STOP button until only the clock is displayed on the remote controller display 2 Press the MODE button for at least 5 seconds to display the cur rent custom code Initially set to 3 Press the TEMP buttons to change the custom code be tween Match the code on the display to the air conditioner custom code Initially set to 4 Press the MODE button ag...

Страница 45: ...art name Exterior Q ty Part name Exterior Q ty Operating manual 1 Cloth tape 1 Installation manual 1 Tapping screw Large 5 Operating manual CD ROM 1 Tapping screw Small 2 Remote controller 1 Wall hook bracket 1 Battery 2 Remote controller holder 1 41 WALL MOUNTED ASYG07 14KGTA ...

Страница 46: ...e Optional communication kit is necessary for installation NOTE Available functions may differ by the remote controller For details refer to the operation manual 13 2 Others Exterior Part name Model name Summary External connect kit UTY XWZX Use to connect with various peripheral devices and air conditioner PCB External input and output PCB UTY XCSXZ2 Use to connect with external devices and air c...

Страница 47: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA ...

Страница 48: ...sheet Color Beige Approximate color of Munsell 10YR 7 5 1 0 Dimensions H W D Net mm 542 799 290 Gross 602 940 375 Weight Net kg 30 31 32 Gross 34 35 36 Connection pipe Size Liquid mm in Ø 6 35 Ø 1 4 Gas Ø 9 52 Ø 3 8 Method Flare Pre charge length m 15 Max length 20 Max height difference 15 Operation range Cooling C 10 to 46 Heating 15 to 24 Drain hose Material PP LLDPE Size mm Ø 13 0 I D Ø 16 0 to...

Страница 49: ...CA Unit mm Airflow 184 120 37 179 399 Bottom view Side view Bulb part 580 109 799 68 290 16 33 30 19 330 542 20 Pitch of bolts for installation Pitch of bolts for installation Top view Side view Side view Front view Drain port Ø42 4 M10 hole 45 OUTDOOR UNIT AOYG07 14KGCA ...

Страница 50: ...k of operating performance Single outdoor unit installation When the upper space is open Unit mm Obstacles at rear only Obstacles at rear and sides 100 or more 250 or more 100 or more 100 or more Obstacles at front Obstacles at front and rear 600 or more 600 or more 100 or more When there is an obstruction in the upper space Unit mm Obstacles at rear and above Obstacles at rear sides and above 100...

Страница 51: ... arranged in a line provide the space as shown in the following example When an obstruction in the upper space When the upper space is open Unit mm Obstacles at rear only Obstacles at front only 200 or more 250 or more 1 000 or more 250 or more Obstacles at front and rear 200 or more 1 000 or more 250 or more When an obstruction in the upper space Unit mm Obstacles at rear and above 1 500 or more ...

Страница 52: ...AUTION Do not install the outdoor unit in two stage where the drain water could freeze Otherwise the drainage from the upper unit may form ice and cause a malfunction of the lower unit When the outdoor temperature is 0 C or less do not use the accessory drain pipe and drain cap If the drain pipe and drain cap are used the drain water in the pipe may freeze in ex tremely cold climate For reverse cy...

Страница 53: ... valve Expansion valve Heat exchanger Heat exchanger INDOOR OUTDOOR Compressor Cooling Heating ThD ThR ThPI ThO ThHO Thermistor Discharge temperature Thermistor Outdoor temperature Thermistor Heat exchanger out temperature ThD ThO ThHO Thermistor Room temperature Thermistor Pipe temperature ThR ThPI Muffler 49 OUTDOOR UNIT AOYG07 14KGCA ...

Страница 54: ...5 Wiring diagrams 5 1 Models AOYG07KGCA AOYG09KGCA AOYG12KGCA and AOYG14KGCA 50 OUTDOOR UNIT AOYG07 14KGCA ...

Страница 55: ...han outdoor unit 1 15 0 858 0 868 10 0 929 0 872 0 882 7 5 0 960 0 933 0 876 0 885 5 0 992 0 964 0 937 0 879 0 889 0 1 000 0 972 0 944 0 887 0 896 Indoor unit is lower than outdoor unit 2 5 1 000 0 972 0 944 0 887 0 896 7 5 0 972 0 944 0 887 0 896 10 0 944 0 887 0 896 15 0 887 0 896 HEATING Pipe length m 5 7 5 10 15 20 Height difference H m Indoor unit is higher than outdoor unit 1 15 0 896 0 879 ...

Страница 56: ...mount g 750 Refrigerant charge Total pipe length m 15 or less 20 Max 20 g m Additional charge g 0 100 7 2 Models AOYG12KGCA and AOYG14KGCA Refrigerant type R32 Refrigerant amount g 850 Refrigerant charge Total pipe length m 15 or less 20 Max 20 g m Additional charge g 0 100 52 OUTDOOR UNIT AOYG07 14KGCA ...

Страница 57: ...47 CFM 948 Heating m3 h 1 560 l s 433 CFM 918 8 2 Model AOYG09KGCA Cooling m3 h 1 610 l s 447 CFM 948 Heating m3 h 1 610 l s 447 CFM 948 8 3 Model AOYG12KGCA Cooling m3 h 1 680 l s 467 CFM 989 Heating m3 h 1 580 l s 439 CFM 930 53 OUTDOOR UNIT AOYG07 14KGCA ...

Страница 58: ...8 4 Model AOYG14KGCA Cooling m3 h 1 680 l s 467 CFM 989 Heating m3 h 1 580 l s 439 CFM 930 54 OUTDOOR UNIT AOYG07 14KGCA ...

Страница 59: ... 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Model AOYG09KGCA Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Heating Octave band sound pressure level dB 0...

Страница 60: ...00 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Model AOYG14KGCA Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band...

Страница 61: ...evel check point 1 m Microphone Microphone Rear Airflow Rear view Side view NOTE Detailed shape of the actual outdoor unit might be slightly different from the one illustrat ed above 57 OUTDOOR UNIT AOYG07 14KGCA ...

Страница 62: ...le 3 mm2 1 5 Limited wiring length m 21 1 Maximum current is the total current of the indoor unit and the outdoor unit 2 Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005 As the regulations of wire size and circuit breaker differ in each country or region select appropri ate devices complied to the regional standard 3 Limit voltage drop to less than 2 If voltage d...

Страница 63: ...program Discharge temp Activate 110 C Compressor stop Reset After 7 minutes Compressor restart Type of protection Protection form Model AOYG12KGCA AOYG14KGCA Circuit protection Current fuse Main PCB 250 V 20 A 250 V 5 A Fan motor protection Terminal protection program Activate 125 25 C Fan motor stop Reset 100 25 C Fan motor restart Compressor protection Terminal protection program Discharge temp ...

Страница 64: ...12 Accessories 12 1 Models AOYG07KGCA AOYG09KGCA AOYG12KGCA and AOYG14KGCA Part name Exterior Q ty Part name Exterior Q ty Installation manual 1 Drain pipe 1 60 OUTDOOR UNIT AOYG07 14KGCA ...

Отзывы: