Type
Wall mounted
Inverter heat pump
Model name
ASUH09LPAS
ASUH12LPAS
Remote controller type
Wireless (Wired, Mobile app*
5
[FGLair
™
] [option])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80°FDB (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
– Heating: Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
– *1: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB)/15 °FWB (-9.44°CWB).
– *2: Heating (5°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 5°FDB (-15.0°CDB)/4°FWB (-15.56°CWB).
– Test conditions are based on AHRI 210/240 2023.
– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *3: Maximum current is maximum value when operated within the operation range.
• *4: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *5: Available on Google Play
™
store or on App Store
®
. Optional WLAN Adapter is also required. For details, refer to the setting manual.
M condition
Model name
ASUH09LPAS
ASUH12LPAS
Capacity
Cooling
Rated
kW
2.64
3.52
Btu/h
9,000
12,000
Min.—Max.
kW
0.97—3.16
1.00—3.72
Btu/h
3,300—10,800
3,400—12,700
Heating
Rated
kW
2.93
4.10
Btu/h
10,000
14,000
Min.—Max.
kW
0.77—3.66
0.91—4.98
Btu/h
2,600—12,500
3,100—17,000
Heating (17°F)*
Rated
kW
1.82
2.58
Btu/h
6,200
8,800
Max.
kW
2.49
3.34
Btu/h
8,500
11,400
Input power
Cooling
Rated
kW
0.72
1.09
Min.—Max.
0.14—1.18
0.14—1.33
Heating
Rated
0.74
1.10
Min.—Max.
0.13—1.23
0.14—1.61
Heating (17°F)*
Rated
0.65
0.85
Max.
1.09
1.34
Current
Cooling
Rated
A
3.5
4.9
Heating
3.7
4.9
EER
Cooling
kW/kW
3.66
3.22
Btu/hW
12.5
11.0
COP
Heating
kW/kW
3.96
3.72
Btu/hW
13.50
12.70
SEER
Cooling
Btu/hW
20.0
HSPF
Heating
Btu/hW
11.0
Power factor
Cooling
%
89.4
96.7
Heating
86.9
97.6
NOTES:
Specifications are based on the following conditions:
• Cooling: Indoor temperature of 80°FDB (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
• Heating: Indoor temperature of 70°FDB (21.11°CDB)/59°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
• *: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB) /60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB)/15°FWB (-9.44°CWB).
• Test conditions are based on AHRI 210/240 2017.
• Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
- 3 -
1. Specifications
WALL MOUNTED
ASUH09-12LPAS
WALL MOUNTED
ASUH09-12LPAS