11. Function settings
To adjust the functions of this product according to the installation environment, various types of
function settings are available.
NOTE:
Incorrect settings can cause a product malfunction.
11-1. Function settings by using remote controller
Some function settings can be changed on the remote controller. After confirming the setting proce-
dure and the content of each function setting, select appropriate functions for your installation envi-
ronment.
¢
Setting procedure by using wireless remote controller
The function number and the associated setting value are displayed on the LCD of the remote con-
troller. Follow the instructions written in the local setup procedure supplied with the remote controller,
and select appropriate setting according to the installation environment.
Before connecting the power supply of the indoor unit, reconfirm following items:
• Piping air tight test and vacuuming have been performed firmly.
• There is no wiring mistake.
Then, connect the power supply of the indoor unit.
Entering function setting mode:
While pressing the FAN SPEED button and TEMP./SELECT ( ) button simultaneously, press the
RESET button to enter the function setting mode.
STEP 1: Setting the remote controller custom code
Use the following steps to select the custom code of the remote controller. (Note that the air condi-
tioner cannot receive a custom code if the air conditioner has not been set for the custom code.)
The custom codes that are set through this process are applicable only to the signal in the function
setting.
For details on how to set the custom codes through the normal process, refer to “Custom code set-
ting for wireless remote controller” on page 1.
1. Press the TEMP./SELECT ( ) ( ) buttons to change the custom
code between → → → . Match the code on the display to the
air conditioner custom code. (Initially set to .) If the custom code
does not need to be selected, press the MODE button, and pro-
ceed to
STEP 2
.
2. Press the MODE button to accept the custom code, and proceed to
STEP 2
.
NOTES:
• The air conditioner custom code is set to prior to shipment.
• The remote controller resets to custom code when the batteries on the remote controller are
replaced. If you use a custom code other than code , reset the custom code after replacing the
batteries.
• If you do not know the air conditioner custom code setting, try each of the custom codes ( →
→ → ) until you find the code that operates the air conditioner.
- 49 -
11-1. Function settings by using remote controller
11. Function settings
WALL MOUNTED
ASUH09-12LPAS
WALL MOUNTED
ASUH09-12LPAS