3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢
Fan speed
Indoor fan speed is defined as below.
Operation mode
Fan mode
Speed (rpm)
ASUG09LMAS
ASUG12LMAS
Heating
POWERFUL
1,290
HIGH
1,220
MED+
1,140
MED
1,060
LOW
900
QUIET
630
Cool air prevention
550
S-LOW
470
Cooling/Fan
POWERFUL
1,290
HIGH
1,220
MED
1,000
LOW
810
QUIET
550
Soft quiet
490*
1
S-LOW
470*
2
Dry
X zone: 550
J zone:550
*1: Fan mode only
*2: Cooling mode only
¢
Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
3-1. Indoor fan control
- (04-7) -