5. INDOOR FAN CONTROL
The airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH,
while the indoor fan only runs.
When Fan mode is set at [AUTO], it operates on [MED] Fan Speed.
01-04
2. FAN OPERATION
3. COOLING OPERATION
Switch the airflow [AUTO], and the indoor fan motor will run according to a room temperature,
as shown in Fig. 3.
On the other hand, if switched in [HIGH] [QUIET], the indoor motor will run at a constant airflow of [COOL]
operation modes QUIET, LOW, MED, HIGH, as shown in Table5.
( Fig.3 : Airflow change - over ( Cooling : AUTO ) )
When the room
temperature rises
When the room
temperature drops
TR : Room temperature
Ts : Setting temperature
TR-Ts > 2°C
1°C > TR-Ts
2°C > TR-Ts > 1°C
=
TR-Ts > 2.5°C
=
1.5°C > TR-Ts
2.5°C > TR-Ts > 1.5°C
=
HIGH mode
MED mode
LOW mode
1. Fan speed
( Table4 : Indoor Fan Speed )
Operation mode
Air flow mode
Speed (rpm)
1480
1320
1220
1020
Cooling/ Fan
Hi
Hi
860
680
270 (480)
1430 (1480)
Me+
Me
Me
Heating
Lo
Lo
1220
1020
Quiet
Quiet
860
1530
1320
1220
1020
900
720
270
1430
1220
1020
900
Dry
S-Lo
X zone: 860
J zone: 780
X zone: 900
J zone: 780
Cool air prevention
AS*G24LFCA(LFCC)
AS*G30LFCA
4. DRY OPERATION
Refer to the Table4.
During the dry mode operation, the fan speed setting can not be changed.
Содержание AO*G24LFLAO*G24LFCC
Страница 3: ......
Страница 4: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Страница 25: ...2 TROUBLE SHOOTING R410A WALL MOUNTED type INVERTER ...
Страница 63: ......
Страница 64: ...3 APPENDING DATA R410A WALL MOUNTED type INVERTER ...
Страница 75: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan Oct 2012 Printed in Japan ...