1. SAFETY 

PRECAUTIONS

1.1.  IMPORTANT! Please read before starting

This air conditioning system meets strict safety and operating standards.
As the installer or service person, it is an important part of your job to install or service the 
system so it operates safely and efficiently.

For safe installation and trouble-free operation, you must:
• Carefully read this instruction booklet before beginning.
• Follow each installation or repair step exactly as shown.
• Observe all local, state, and national electrical codes.
• Pay close attention to all danger, warning, and caution notices given in this manual.

WARNING:

This symbol refers to a hazard or unsafe practice which can result in 
severe personal injury or death.

CAUTION:

This symbol refers to a hazard or unsafe practice which can result in 
personal injury and the potential for product or property damage.

• Hazard alerting symbols

: Electrical

: Safety/alert

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. 
If you require help for a special problem, contact our sales/service outlet or your certified 
dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improper installation or maintenance 
service, including failure to follow the instructions in this document.

1.2. SPECIAL 

PRECAUTIONS

When Wiring

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A 
QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.

• Do not supply power to the unit until all wiring and tubing are completed or reconnected 

and checked.

• Highly dangerous electrical voltages are used in this system. Carefully refer to the wir-

ing diagram and these instructions when wiring. Improper connections and inadequate 
earthing (grounding) can cause accidental injury or death.

• Earth (Ground) the unit following local electrical codes.
• Connect all wiring tightly. Loose wiring may cause overheating at connection points and 

a possible 

fi

 re hazard.

When Transporting

Be careful when picking up and moving the indoor and outdoor units. Get a partner to 
help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin 
aluminum 

fi

 ns on the air conditioner can cut your 

fi

 ngers.

When Installing...

...In a Ceiling or Wall

Make sure the ceiling/wall is strong enough to hold the unit’s weight. It may be necessary 
to construct a strong wood or metal frame to provide added support.

...In a Room

Properly insulate any tubing run inside a room to prevent “sweating” that can cause 
dripping and water damage to walls and 

fl

 oors.

...In an Area with High Winds

Securely anchor the outdoor unit down with bolts and a metal frame.
Provide a suitable air baf

fl

 e.

...In a Snowy Area (for Heat Pump-type Systems)

Install the outdoor unit on a raised platform that is higher than drifting snow.

When Connecting Refrigerant Tubing

• Keep all tubing runs as short as possible.
• Use the 

fl

 are method for connecting tubing.

• Apply refrigerant lubricant to the matching surfaces of the 

fl

 are and union tubes before 

connecting them, then tighten the nut with a torque wrench for a leak-free connection.

• Check carefully for leaks before opening the refrigerant valves.

When Servicing

• Turn the power OFF at the main circuit breaker panel before opening the unit to check or 

repair electrical parts and wiring.

• Keep your 

fi

 ngers and clothing away from any moving parts.

• Clean up the site after you 

fi

 nish, remembering to check that no metal scraps or bits of 

wiring have been left inside the unit being serviced.

• After installation, explain correct operation to the customer, using the operating manual.

 DANGER

Never touch electrical components immediately after the power supply has been turned 
off. Electrical shock may occur. After turning off the power, always wait 5 minutes or more 
before touching electrical components.

• Be sure to read this Manual thoroughly before installation.
• The warnings and precautions indicated in this Manual contain important information 

pertaining to your safety. Be sure to observe them.

• Hand this Manual, together with the Operating Manual to the customer. 
• Request the customer to keep them on hand for future use, such as for relocating or 

repairing the unit.

 WARNING

Request your dealer or a professional installer to install the unit in accordance with this 
Manual. 
An improperly installed unit can cause serious accidents such as water leakage, electric 
shock, or fire. 
If the unit is instruction in disregard of the instructions in the Installation Manual, it will 
void the manufacturer’s warranty.

Do not turn ON the power until all work has been completed. 
Turning ON the power before the work is completed can cause serious accidents such 
as electric shock or fire.

If refrigerant leaks while work is being carried out, ventilate the area.
If the refrigerant comes in contact with a flame, it produces a toxic gas.

Installation must be performed in accordance with the requirement of NEC (National 
Electrical Code) and CEC (Canadian Electrical Code) by authorized personnel only.

Except for EMERGENCY, never turn off main as well as sub breaker of the indoor units 
during operation. It will cause compressor failure as well as water leakage. First, stop 
the indoor unit by operating the control unit, converter or external input device and then 
cut the breaker.
Make sure to operate through the control unit, converter or external input device.
When the breaker is designed, locate it at a place where the users cannot start and stop 
in the daily work.

INSTALLATION MANUAL

PART No. 9373370444
VRF system indoor unit (Wall mounted type)

Contents

1. SAFETY 

PRECAUTIONS 

........................................................................................... 1

1.1.  IMPORTANT! Please read before starting ........................................................... 1
1.2. SPECIAL PRECAUTIONS ................................................................................... 1

2.  ABOUT THIS PRODUCT ............................................................................................ 2

2.1.  Precautions for using R410A refrigerant .............................................................. 2
2.2.  Special tools for R410A ....................................................................................... 2
2.3. Accessories ......................................................................................................... 2
2.4. Optional parts ...................................................................................................... 2
2.5.  About unit of the length ........................................................................................ 2

3. INSTALLATION 

WORK 

.............................................................................................. 3

3.1.  Selecting an installation location .......................................................................... 3
3.2. Installation dimension .......................................................................................... 3
3.3.  Installing the unit .................................................................................................. 3

4. PIPE 

INSTALLATION 

.................................................................................................. 4

4.1.  Selecting the pipe material .................................................................................. 4
4.2. Pipe requirement ................................................................................................. 5
4.3.  Flare connection (pipe connection) ...................................................................... 5

5.  FORMING THE DRAIN HOSE AND PIPE .................................................................. 5

6. ELECTRICAL 

WIRING 

................................................................................................ 6

6.1. Electrical requirement .......................................................................................... 7
6.2. Wiring method ...................................................................................................... 7
6.3. Unit wiring ............................................................................................................ 7
6.4. Wiring ................................................................................................................... 9
6.5.  Optional parts wiring ............................................................................................ 9
6.6.  External input and external output (Optional parts) ............................................. 9

7. FIELD 

SETTING 

........................................................................................................ 11

7.1.  Setting the address ............................................................................................ 11
7.2.  Custom code setting .......................................................................................... 12
7.3. Function setting ................................................................................................. 13

8. FINISHING................................................................................................................. 14

8.1.  Connection pipe, cable and drain hose ............................................................. 14
8.2.  Installing front cover ........................................................................................... 15

9. TEST 

RUN 

................................................................................................................. 15

9.1.  Test run using Outdoor unit (PCB) ..................................................................... 15
9.2.  Test run using remote controller ........................................................................ 15

10. CHECK LIST 

............................................................................................................. 15

11. ERROR 

CODES 

........................................................................................................ 16

9373370444_IM.indb   1

9373370444_IM.indb   1

29/11/2017   AM 11:48:43

29/11/2017   AM 11:48:43

Содержание Airstage ASUB18TLAV1

Страница 1: ...Français Español MANUEL D INSTALLATION MANUAL DE INSTALACIÓN UNITÉ INTÉRIEURE Type montage mural UNIDAD INTERIOR Tipo montado en pared Pour le personnel agréé uniquement Únicamente para personal de servicio autorizado PART No 9373370444 9373370444_IM indb 1 9373370444_IM indb 1 29 11 2017 AM 11 48 42 29 11 2017 AM 11 48 42 ...

Страница 2: ...aker panel before opening the unit to check or repair electrical parts and wiring Keep your fingers and clothing away from any moving parts Clean up the site after you finish remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced After installation explain correct operation to the customer using the operating manual DANGER Never touch electrical c...

Страница 3: ...ump adapter A conventional vacuum pump can be used by installing a vacuum pump adapter Be sure that the pump oil does not back flow into the system Use one capable for vacuum suction of 5 Torr 755 mm Hg 100 7 kPa Gas leakage detector Special gas leakage detector for HFC refrigerant R410A 2 3 Accessories WARNING For installation purposes be sure to use the parts supplied by the manufacturer or othe...

Страница 4: ... install the unit where it will be exposed to direct sunlight 3 2 Installation dimension For the drain hose exten sion use a drain hose with a 5 8 in 16 mm inside diameter 71 in 1800 mm or more 60 in 1500 mm or more Right side 8 in 200 mm or more 3 in 60 mm or more Left side 2 in 50 mm or more Wall hook bracket 3 3 Installing the unit WARNING Install the air conditioner in a location which can wit...

Страница 5: ...f copper pipes used with R410A are as shown in the table Never use copper pipes thinner than those indicated in the table even if they are avail able on the market Wall hook bracket Tapping screw big 3 3 2 Cutting the hole in the wall for the connecting piping WARNING If the wall pipe is not used the cable may touch metal and cause electric leakage 1 Cut a 3 1 8 in 80 mm diameter hole in the wall ...

Страница 6: ...A flare tools to achieve the specified flaring Use a thickness gauge to measure the dimension A It is recommended that a R410A flaring tool is used Width across flats Pipe outside diameter in mm Width across flats of Flare nut in mm 1 4 6 35 11 16 17 3 8 9 52 7 8 22 1 2 12 70 1 26 5 8 15 88 1 1 8 29 3 4 19 05 1 7 16 36 4 3 2 Bending pipes The pipes are shaped by your hands or pipe bender Be carefu...

Страница 7: ...nd positively Connect the connection cable firmly to the terminal board Imperfect installation may cause a fire If the supply cable is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard CAUTION Earth Ground the unit Do not connect the earth ground cable to a gas pipe water pipe lightning rod or a telephone earth ground cable ...

Страница 8: ...WORKS compatible cable Remote con troller cable 2 wire type 22 AWG to 16 AWG 0 33 to 1 25 mm Sheathed PVC cable Non polar 2 core twisted pair 18AWG Thermostat cable 2 core Use sheathed non twisted pair cable Remote con troller cable 3 wire type 22 AWG 0 33 mm Sheathed PVC cable Polar 3 core 6 2 Wiring method Example 2 2 2 Outdoor unit or RB unit 1 Breaker 1 Ground Fault Equipment Breaker GFEB Brea...

Страница 9: ...loose 3 Use the specified cables connect them securely and fasten them so that there is no stress placed on the terminals 4 Use an appropriate screwdriver to tighten the terminal screws Do not use a screwdriver that is too small otherwise the screw heads may be dam aged and prevent the screws from being properly tightened 5 Do not tighten the terminal screws too much otherwise the screws may break...

Страница 10: ...al parts 6 6 1 External input Indoor unit can be Operation Stop Emergency stop or Forced stop by using indoor unit PCB CNA01 or CNA02 Operation Stop mode Emergency stop mode or Forced stop mode can be selected with function setting of indoor unit Indoor unit can be Forced thermostat off by using indoor unit PCB CNA03 or CNA04 A twisted pair cable 22 AWG should be used Maximum length of cable is 49...

Страница 11: ... Connected unit c Select very low current use contacts usable at DC 12 V DC 1 mA or less d The wiring is different from Apply voltage terminals Be sufficiently careful when wiring When connected to Dry contact terminals of multiple indoor units with a connected unit insulate each indoor unit with relay etc as shown on below example K1 CNA02 CNA02 CNA02 K2 K3 K4 K5 K6 Power supply for relay Indoor ...

Страница 12: ...ing when turning ON output to the connected external heater can be set by changing Dip switch on PC board Dip switch SET2 SW3 Fan setting when ON is output to the external heater Explanation OFF Factory setting OFF For the fan setting details see the Design Technical Manual ON ON 7 FIELD SETTING There are 3 methods for address setting by FIELD SETTING as follows Please set by either of the methods...

Страница 13: ...lt in failure 3 Remote controller address i 3 wire type Rotary switch RC AD SW Factory setting 0 When connecting multiple indoor units to 1 standard wired remote controller set the address at RC AD SW in sequence from 0 Setting Setting range Type of switch Remote controller ad dress 0 to 15 Setting example 0 RC AD Example If 4 indoor units are connected Remote controller Indoor unit Indoor unit In...

Страница 14: ...t Stop Allow an external controller to start or stop the system or to perform an emergency stop If an emergency stop is performed from an external controller all refrigerant sys tems will be disabled If forced stop is set indoor unit stops by the input to the external input terminals and Start Stop by a remote controller is restricted 01 Emergency stop 02 Forced Stop Error report target 47 00 All ...

Страница 15: ... Green TIMER indicator lamp Orange FILTER indicator lamp Red 10 sec 1 cycle 12 sec 8 sec ON OFF 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s ON OFF ON OFF ON Refrigerant address example Example ADDRESS 30 OPERATION indicator lamp Green TIMER indicator lamp Orange FILTER indicator lamp Red 9 sec 1 cycle 12 sec ON OFF 1 0s 1 0s 1 0s 1 0s 1 0s 1 0s 1 0s 0 5s 0 5s 0 5s 0 5s 0 5s 0 5s ON...

Страница 16: ...e used for the test run 9 2 Test run using remote controller Refer to the Installation Manual for the remote controller to perform the test run using the remote controller When the air conditioner is being test run the OPERATION and TIMER indicator lamp flash slowly at the same time 10 CHECK LIST Pay special attention to the check items below when installing the indoor unit s After installation is...

Страница 17: ...1 Indoor unit room temp thermistor error 4 2 Indoor unit heat ex temp thermistor error 5 1 Indoor unit fan motor 1 error 5 2 Indoor unit coil expansion valve error 5 3 Indoor unit water drain abnormal 9 15 Outdoor unit miscellaneous error 10 8 Poor refrigerant circula tion 13 1 RB unit error Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Wired remote controller display UTY RNKU ...

Отзывы: