8. FINISHING

(1) Insulate between pipes.
•  Overlap the connection pipe heat insulation and indoor unit pipe heat insulation.
•  Wrapping the connection pipe with cloth tape over the range within which they 

fi

 t into 

the rear piping housing section.

•  Fasten the pipe bracket with the screw.
(2) Fixing the pipe and conduit with cable ties.
(3)  Fill the gap between the outside wall pipe hole and the pipe with sealer so that rain 

water and wind cannot blow in.

(4)  Fasten the drain hose to the outside wall, etc.

Cloth 
tape

Front side of 
pipe bracket

Wrap the each pipe 
with cloth tape

Pipe 
bracket

Screw

Conduit

Left piping

For connection from the left rear

Wall pipe

Connection wire

Drain hose

Connection 
pipe

Connection wire

Drain hose

Pipe

Conduit

Pipe

Cable tie

30 mm 

(1-3/16 in.)

Check the following:

GOOD

PROHIBITED

Accumulated 
drain water

No upward 
slope

50 mm (1-15/16 in.) 
or less from ground

Stopping 
downward

No upward 
slope

End of drain hose 
is immersed in 
water.

Drainage 
channel

Air

9. TEST RUN

 WARNING

Do not turn on the power until all installation work is complete.

 CAUTION

When restarting after a long period of disuse in the winter, turn the power switch on at 
least 12 hours before starting the unit.

Check items

(1)  Is operation of each button on the remote controller normal?
(2) Does each lamp light normally?
(3) Do air 

fl

 ow direction louvers operate normally?

(4) Is the drain normal?
(5)  Do not have an abnormal noise and vibration during operation?

 Do not operate the air conditioner in test run for a long time.

7.3.  Conduit mounting method

(1) Fasten the indoor unit wire harness to the conduit holder using the lock nut.
 

IMPORTANT: Refer to [7.1. Wiring system diagram] about the length of indoor unit wire 
harness.

(2) Remove the screws, then remove the cable clamper.
(3) Connect indoor unit wire harness to the terminal.
 

Refer to the wiring diagram

(4) Use the screws to install the cable clamper.

Lock nut

Conduit 
holder

Conduit 
connector

]1

7.4.  How to connect wiring to the terminals

Caution when wiring cable
When stripping off the insulation of a lead wire, always use a special tool such as a wire 
stripper. If there is no special tool available, carefully strip the insulation with a knife etc.
(1)  Use crimp-type terminals with insulating sleeves as shown in the figure below to 

connect to the terminal block.

(2)  Securely clamp the crimp-type terminals to the wires using an appropriate tool so that 

the wires do not come loose.

Strip: 10 mm (6/16 in.)

Sleeve

Crimp-type 
terminal

(3)  Use the speci

fi

 ed wires, connect them securely, and fasten them so that there is no 

stress placed on the terminals.

(4)  Use an appropriate screwdriver to tighten the terminal screws. Do not use a 

screwdriver that is too small, otherwise, the screw heads may be damaged and 
prevent the screws from being properly tightened.

(5)  Do not tighten the terminal screws too much, otherwise, the screws may break.

Screw with special washer

Screw with 
special washer

Crimp-type terminal

Terminal blocks

Crimp-type 
terminal

Wire

Wire

(6)  See the table below for the terminal screw tightening torques.

Tightening torque [N·m (kgf·cm)]

M4 screw

1.2 to 1.8 (12 to 18)

 CAUTION

Match the terminal block numbers and connection cable colors with those of the 
outdoor unit or branch box.
Erroneous wiring may cause burning of the electric parts.

Connect the connection cables 

fi

 rmly to the terminal block. Imperfect installation may 

cause a 

fi

 re.

Always fasten the outside covering of the connection cable with the cable clamp. (If 
the insulator is chafed, electric discharge may occur.)

Always connect the earth (ground) wire.

Do not use the earth (ground) screw of the indoor unit for the connection other than a 
speci

fi

 ed outdoor unit or branch box.

9378533059_IM.indb   8

9378533059_IM.indb   8

9/20/2013   11:26:13 AM

9/20/2013   11:26:13 AM

Содержание AGU9RLF

Страница 1: ...T Floor Type UNITÉ INTÉRIEURE type sol For authorized service personnel only Pour le personnel agréé uniquement AIR CONDITIONER MANUAL DE INSTALACIÓN UNIDAD DE INTERIOR tipo de piso Solo para personal autorizado 9378533059_IM indb 1 9378533059_IM indb 1 9 20 2013 11 24 59 AM 9 20 2013 11 24 59 AM ...

Страница 2: ...r fingers and clothing away from any moving parts Clean up the site after you finish remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced After installation explain correct operation to the customer using the operating manual WARNING Never touch electrical components immediately after the power supply has been turned off Electric shock may occur...

Страница 3: ...d Shape Q ty Name and Shape Q ty Operating Manual 1 Remote controller holder 1 Installation Manual This manual 1 Cloth tape 1 Wall hook bracket 1 Tapping screw M4 25 mm 9 Name and Shape Q ty Name and Shape Q ty Remote controller 1 Tapping screw M3 12 mm 2 Battery 2 Air cleaning filter 2 Cable tie 1 The following items are necessary to install this air conditioner The items are not included with th...

Страница 4: ... cannot reach the unit 6 INSTALLATION WORK 1 6 1 Installation dimensions Wall cap 50 1 15 16 or over 80 3 2 16 or over 100 3 15 16 or over 80 3 2 16 or over Unit mm in 150 5 14 16 or below from the floor Remote controller holder Tapping screw small Remote controller EMBEDDING THE INDOOR UNIT IN A WALL When installing a grating use a grating with narrow upper and lower horizontal bars so that the a...

Страница 5: ...RIGHT BOTTOM PIPING Unit mm in FOR LEFT BOTTOM PIPING 50 1 15 16 182 7 3 16 64 2 8 16 29 1 2 16 29 1 2 16 135 5 5 16 5 3 16 to 10 6 16 Fasten with vinyl tape Wall cap Wall pipe Field supplied Inside Wall Outside WARNING If the wall pipe is not used the wire interconnecting the indoor and outdoor units may touch metal and cause electric leakage 6 5 Forming piping 1 Pass the refrigerant pipe through...

Страница 6: ...stall the wall hook bracket so that it is correctly positioned horizontally and vertically If the wall hook bracket is tilted water will drip to the floor 2 Install the wall hook bracket so that it is strong enough to support the weight of the unit Fasten the wall hook bracket to the wall with 5 or more screws through the holes near the outer edge of the bracket Check that there is no rattle at th...

Страница 7: ...e that the piping is well insulated When the flare nut is tightened properly by your hand hold the body side coupling with a wrench then tighten with a torque wrench See following table for the flare nut tightening torques Wrench fixed Connection pipe Flare nut Indoor unit pipe Tighten with two wrenches Torque wrench Flare nut mm in Tightening torque N m kgf cm 6 35 1 4 dia 16 to 18 160 to 180 9 5...

Страница 8: ...it wire harness to the terminal Refer to the wiring diagram 4 Use the screws to install the cable clamper Lock nut Conduit holder Conduit connector 1 7 4 How to connect wiring to the terminals Caution when wiring cable When stripping off the insulation of a lead wire always use a special tool such as a wire stripper If there is no special tool available carefully strip the insulation with a knife ...

Страница 9: ... connect kit 11 1 Before install optional remote controller When you use optional remote controller some functions may not be used Please use the recommended optional remote controller CAUTION Before installing be sure to disconnect all power supply Don t touch the heat exchanger During installing or removing operation be sure not to have wire caught by parts or draw it hard Or it may result troub...

Страница 10: ...w to set the custom codes through the normal process refer to Remote control ler custom code 1 Press SET TEMP button to change the custom code between Match the code on the dis play to the air conditioner custom code initially set to If the custom code does not need to be selected press the MIN HEAT button and proceed to STEP 2 2 Press the MODE button and check that the indoor unit can receive sig...

Страница 11: ...itioner cannot receive a custom code if the air conditioner has not been set for the custom code 1 Press the START STOP button until only the clock is displayed on the remote controller display 2 Press the MODE button for at least five seconds to display the current custom code initially set to 3 Press the SET TEMP button to change the custom code between Match the code on the display to the air c...

Страница 12: ...ddle temp sensor error 5 1 Indoor unit fan motor error 5 3 Drain pump error 5 7 Damper error 5 15 Indoor unit error 6 2 Outdoor unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discharge temp sensor error 7 2 Compressor temp sensor error 7 3 Out...

Отзывы: