background image

En-10

1

11.5.  Connecting cable to control board connector

(1) Connect the cable the circuit board and hang on the hooks.

PCB

CN 6

CN 21 

(EX. OUT2)

CN 14 

(EX. IN1)

CN 20 

(EX. OUT1)

Option type

Connector 

No.

Wired remote controller 
Simple remote controller

CN 6

External input

CN 14 

(EX. IN1)

External output 
(operation status)

CN 20 

(EX. OUT1)

External output 
(error status)

CN 21 

(EX. OUT2)

(2) Install the control cover.
(3) Use cable clamper and screw to fasten the cable of wired remote controller.
(4) Fix the cable tie holder with the screw and bind the cable of external kit with the cable tie.

Earth 
(Ground) 
wire

Screw

Hook

Cable

Cable tie

Cable tie holder

Cable 
clump

Screw

Screw

]1

11.6.  Side panel L and control cover installation

Install Side panel L and control cover by the reverse procedures as stated in “11.4. Side 
panel L and control cover removal”.

12.  FUNCTION SETTING

Perform the “FUNCTION SETTING” according to the installation conditions using the 
remote controller.

 CAUTION

Con

fi

 rm whether the wiring work for Outdoor unit or Branch box has been 

fi

 nished.

Con

fi

 rm that the cover for the electrical enclosure on the outdoor unit is in place.

•  This procedure changes to the function settings used to control the indoor unit 

according to the installation conditions. Incorrect settings can cause the indoor unit to 
malfunction.

•  After the power is turned on, perform the “FUNCTION SETTING” according to the 

installation conditions using the remote controller.

•  The settings may be selected between the following two: Function Number or Setting 

Value.

•  Settings will not be changed if invalid numbers or setting values are selected.
•  Refer to the installation manual enclosed with the remote controller when the wired 

remote controller (option) is used.

Entering the Function Setting Mode

While pressing the POWERFUL button and SET TEMP. ( ) simultaneously, press the 
RESET button to enter the function setting mode.

STEP 1

Selecting the Remote Controller Custom Code

Use the following steps to select the custom code of the remote con-
troller. (Note that the air conditioner cannot receive a custom code if 
the air conditioner has not been set for the custom code.)
The custom codes that are set through this process are applicable only 
to the signals in the FUNCTION SETTING. For details on how to set 
the custom codes through the normal process, refer to Remote control-
ler custom code.

(1)  

Press SET TEMP. (

 / 

) button to change the custom 

code between 

. Match the code on the dis-

play to the air conditioner custom code. (initially set to  ) 
(If the custom code does not need to be selected, press the 
MIN. HEAT button and proceed to STEP 2.)

(2)  

Press the MODE button and check that the indoor unit can 
receive signals at the displayed custom code.

(3)  

Press the MIN. HEAT button to accept the custom code, 
and proceed to STEP 2.

The air conditioner custom code is set to A prior to shipment. 
Contact your retailer to change the custom code.

The remote controller resets to custom code A when the batteries in the remote 
controller are replaced. If you use a custom code other than custom code A, reset the 
custom code after replacing the batteries.
If you do not know the air conditioner custom code setting, try each of the custom 
codes (

) until you 

fi

 nd the code which operates the air conditioner.

STEP 2

Selecting the Function Number and Setting Value

(1)  

Press the SET TEMP. (  / 

) buttons to select the 

function number. (Press the MIN. HEAT button to 
switch between the left and right digits.)

(2)  

Press the POWERFUL button to proceed to setting 
value. (Press the POWERFUL button again to return 
to the function number selection.)

(3)  

Press the SET TEMP. (  / 

) buttons to select the 

setting value. (Press the MIN. HEAT button to switch 
between the left and right digits.)

(4)  

Press the MODE button, and START/STOP button, in 
the order listed to con

fi

 rm the settings.

(5)  

Press the RESET button to cancel the function set-
ting mode.

(6)  

After completing the FUNCTION SETTING, be sure 
to turn off the power and turn it on again.

 CAUTION

After turning off the power, wait 10 seconds or more before turning on it again.
The Function Setting does not become active unless the power is turned off then on 
again.

Filter Sign

The indoor unit has a sign to inform the user that it is time to clean the 

fi

 lter. Select the 

time setting for the 

fi

 lter sign display interval in the table below according to the amount 

of dust or debris in the room. If you do not wish the 

fi

 lter sign to be displayed, select the 

setting value for “No indication”.

(

...  Factory setting)

Setting Description

Function Number

Setting Value

Standard (400 hours)

11

00

Long interval (1,000 hours)

01

Short interval (200 hours)

02

No indication

03

Function Number

Setting 

Value

9378533059_IM.indb   10

9378533059_IM.indb   10

9/20/2013   11:26:15 AM

9/20/2013   11:26:15 AM

Содержание AGU9RLF

Страница 1: ...T Floor Type UNITÉ INTÉRIEURE type sol For authorized service personnel only Pour le personnel agréé uniquement AIR CONDITIONER MANUAL DE INSTALACIÓN UNIDAD DE INTERIOR tipo de piso Solo para personal autorizado 9378533059_IM indb 1 9378533059_IM indb 1 9 20 2013 11 24 59 AM 9 20 2013 11 24 59 AM ...

Страница 2: ...r fingers and clothing away from any moving parts Clean up the site after you finish remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced After installation explain correct operation to the customer using the operating manual WARNING Never touch electrical components immediately after the power supply has been turned off Electric shock may occur...

Страница 3: ...d Shape Q ty Name and Shape Q ty Operating Manual 1 Remote controller holder 1 Installation Manual This manual 1 Cloth tape 1 Wall hook bracket 1 Tapping screw M4 25 mm 9 Name and Shape Q ty Name and Shape Q ty Remote controller 1 Tapping screw M3 12 mm 2 Battery 2 Air cleaning filter 2 Cable tie 1 The following items are necessary to install this air conditioner The items are not included with th...

Страница 4: ... cannot reach the unit 6 INSTALLATION WORK 1 6 1 Installation dimensions Wall cap 50 1 15 16 or over 80 3 2 16 or over 100 3 15 16 or over 80 3 2 16 or over Unit mm in 150 5 14 16 or below from the floor Remote controller holder Tapping screw small Remote controller EMBEDDING THE INDOOR UNIT IN A WALL When installing a grating use a grating with narrow upper and lower horizontal bars so that the a...

Страница 5: ...RIGHT BOTTOM PIPING Unit mm in FOR LEFT BOTTOM PIPING 50 1 15 16 182 7 3 16 64 2 8 16 29 1 2 16 29 1 2 16 135 5 5 16 5 3 16 to 10 6 16 Fasten with vinyl tape Wall cap Wall pipe Field supplied Inside Wall Outside WARNING If the wall pipe is not used the wire interconnecting the indoor and outdoor units may touch metal and cause electric leakage 6 5 Forming piping 1 Pass the refrigerant pipe through...

Страница 6: ...stall the wall hook bracket so that it is correctly positioned horizontally and vertically If the wall hook bracket is tilted water will drip to the floor 2 Install the wall hook bracket so that it is strong enough to support the weight of the unit Fasten the wall hook bracket to the wall with 5 or more screws through the holes near the outer edge of the bracket Check that there is no rattle at th...

Страница 7: ...e that the piping is well insulated When the flare nut is tightened properly by your hand hold the body side coupling with a wrench then tighten with a torque wrench See following table for the flare nut tightening torques Wrench fixed Connection pipe Flare nut Indoor unit pipe Tighten with two wrenches Torque wrench Flare nut mm in Tightening torque N m kgf cm 6 35 1 4 dia 16 to 18 160 to 180 9 5...

Страница 8: ...it wire harness to the terminal Refer to the wiring diagram 4 Use the screws to install the cable clamper Lock nut Conduit holder Conduit connector 1 7 4 How to connect wiring to the terminals Caution when wiring cable When stripping off the insulation of a lead wire always use a special tool such as a wire stripper If there is no special tool available carefully strip the insulation with a knife ...

Страница 9: ... connect kit 11 1 Before install optional remote controller When you use optional remote controller some functions may not be used Please use the recommended optional remote controller CAUTION Before installing be sure to disconnect all power supply Don t touch the heat exchanger During installing or removing operation be sure not to have wire caught by parts or draw it hard Or it may result troub...

Страница 10: ...w to set the custom codes through the normal process refer to Remote control ler custom code 1 Press SET TEMP button to change the custom code between Match the code on the dis play to the air conditioner custom code initially set to If the custom code does not need to be selected press the MIN HEAT button and proceed to STEP 2 2 Press the MODE button and check that the indoor unit can receive sig...

Страница 11: ...itioner cannot receive a custom code if the air conditioner has not been set for the custom code 1 Press the START STOP button until only the clock is displayed on the remote controller display 2 Press the MODE button for at least five seconds to display the current custom code initially set to 3 Press the SET TEMP button to change the custom code between Match the code on the display to the air c...

Страница 12: ...ddle temp sensor error 5 1 Indoor unit fan motor error 5 3 Drain pump error 5 7 Damper error 5 15 Indoor unit error 6 2 Outdoor unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discharge temp sensor error 7 2 Compressor temp sensor error 7 3 Out...

Отзывы: