4. ELECTRICAL REQUIREMENT

The indoor unit is powered from the outdoor unit or branch box. Do not power indoor unit 
from separate power source.

 WARNING

Refer to local codes for acceptable cable type.

5.  SELECTING THE MOUNTING POSITION

Decide the mounting position with the customer as follows:
(1)  Install the indoor unit level on a strong wall which is not subject to vibration.
(2)  The inlet and outlet ports should not be obstructed: the air should be able to blow all 

over the room.

(3)  Install the unit a dedicated electrical branch circuit.
(4)  Do not install the unit where it will be exposed to direct sunlight.
(5)  Install the unit where connection to the outdoor unit or branch box is easy.
(6)  Install the unit where the drain pipe can be easily installed.
(7)  Take servicing, etc. into consideration and leave the spaces shown in the figure. Also 

install the unit where the filter can be removed.

Correct initial installation location is important because it is dif

fi

 cult to move unit after it is 

installed.

 WARNING

Select installation locations that can properly support the weight of the indoor. Install 
the units securely so that they do not topple or fall.

 CAUTION

Do not install the unit in the following areas:

•  Area with high salt content, such as at the seaside.

It will deteriorate metal parts, causing the parts to fail or the unit to leak water.

•  Area 

fi

 lled with mineral oil or containing a large amount of splashed oil or steam, 

such as a kitchen.
It will deteriorate plastic parts, causing the parts to fail or the unit to leak water.

•  Area that generates substances that adversely affect the equipment, such as 

sulfuric gas, chlorine gas, acid, or alkali.
It will cause the copper pipes and brazed joints to corrode, which can cause 
refrigerant leakage.

•  Area that can cause combustible gas to leak, contains suspended carbon 

fi

 bers or 

fl

 ammable dust, or volatile in

fl

 ammables such as paint thinner or gasoline.

If gas leaks and settles around the unit, it can cause a 

fi

 re.

•  Area where animals may urinate on the unit or ammonia may be generated.

Do not use the unit for special purposes, such as storing food, raising animals, growing 
plants, or preserving precision devices or art objects.
It can degrade the quality of the preserved or stored objects.

Do not install where there is the danger of combustible gas leakage.

Do not install the unit near a source of heat, steam, or 

fl

 ammable gas.

Install the unit where drainage does not cause any trouble.

Install the indoor unit, outdoor unit, branch box, power supply cable, transmission 
cable, and remote control cable at least 1 m (39 in.) away from a television or radio 
receivers. The purpose of this is to prevent TV reception interference or radio noise. 
(Even if they are installed more than 1 m (39 in.) apart, you could still receive noise 
under some signal conditions.)

If children under 10 years old may approach the unit, take preventive measures so that 
they cannot reach the unit.

6. INSTALLATION WORK

]1

6.1. Installation dimensions

(Wall cap)

50 (1-15/16) or over

80 (3-2/16) or over

100 (3-15/16) or over

80 (3-2/16) or over

Unit: mm (in.)

150 (5-14/16) or 
below from the 

fl

 oor

Remote controller 
holder

Tapping screw 
(small)

Remote 
controller

EMBEDDING THE INDOOR UNIT IN A WALL

•  When installing a grating, use a grating with narrow upper and lower horizontal bars 

so that the air

fl

 ow from the upper and lower air outlets does not contact the bars. If the 

horizontal bars will block the lower air outlet, use a stand, etc., to adjust the height of 
the indoor unit. If the upper or lower air outlet is blocked, the air conditioner will not be 
able to cool or warm the room well.

•  Do not block the receiver with the grating. Otherwise, the grating will interfere with the 

remote controller signal and signi

fi

 cantly reduce the distance and area (angle) from 

which the signals can be received.

•  Use a grating with vertical bars, etc., that has at least 75% open area. If the grating has 

horizontal bars or if the open area is less than 75%, performance could be reduced.

•  When the indoor unit is embedded in a wall (built-in), the time it takes for the room 

temperature to reach the set temperature will increase.

20 (13/16)~
30 (1-3/16)

Upper air outlet

80 (3-2/16) or more

80 (3-2/16) or more

Indoor 
unit

Unit: mm (in.)

Lower air outlet

100 (3-15/16) or more

Grating

When embedding the indoor unit in a wall, restrict the movement of the horizontal vane 
for the upper air outlet so that it only operates horizontally. If this setting is not performed, 
heat will build up in the wall and the room will not be cooled or warmed properly.

Please explain the vane setting of direction only horizontally to the customer.

HOW TO SETTING VANE
Perform the “FUNCTION SETTING” according to the installation condition using the 
remote controller. Refer to “12. FUNCTION SETTING”.

]1

6.2.  Indoor unit piping direction

The piping can be connected in the 6 directions indicated by (1), (2), (3), (4), (5) and (6) 
in the 

fi

 gure. When the piping is connected in direction (2) or (5), cut along the piping 

groove in the side of the base with a hacksaw.
When connecting the piping in direction (3), (6) cut a notch in the thin wall at the front 
bottom of the base.

(1) Right rear 

outlet

(2) Right outlet

(3) Right bottom 

outlet

(4) Left rear 

outlet

(5) Left outlet

(Rear)

(6) Left bottom 

outlet

6.3.  Side panel L, R removal and installation

The intake grille removal

(1) Open the intake grille.
(2) Remove the rope.
(3) Lay down the intake grille, until the axle at the bottom of the intake grille is removed.

The intake grille installation

(1) The 

fi

 xing axle of the intake grille is installed on the Panel.

(2) Lift the intake grille upward.

The side panel L, R removal

(1) Remove intake grille (Reference the intake grille removal.)
(2) Remove 4 screws.
(3)  The middle 

fi

 nger is hung on the lower part as shown in the 

fi

 gure, and it pulls to the 

front, pushing [

] mark, and bottom hooks (2 position) is removed from Base.

(4)  The side panel is pulled to the front, raising the upper surface, and a side panel is 

removed.

9378533059_IM.indb   4

9378533059_IM.indb   4

9/20/2013   11:26:08 AM

9/20/2013   11:26:08 AM

Содержание AGU9RLF

Страница 1: ...T Floor Type UNITÉ INTÉRIEURE type sol For authorized service personnel only Pour le personnel agréé uniquement AIR CONDITIONER MANUAL DE INSTALACIÓN UNIDAD DE INTERIOR tipo de piso Solo para personal autorizado 9378533059_IM indb 1 9378533059_IM indb 1 9 20 2013 11 24 59 AM 9 20 2013 11 24 59 AM ...

Страница 2: ...r fingers and clothing away from any moving parts Clean up the site after you finish remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced After installation explain correct operation to the customer using the operating manual WARNING Never touch electrical components immediately after the power supply has been turned off Electric shock may occur...

Страница 3: ...d Shape Q ty Name and Shape Q ty Operating Manual 1 Remote controller holder 1 Installation Manual This manual 1 Cloth tape 1 Wall hook bracket 1 Tapping screw M4 25 mm 9 Name and Shape Q ty Name and Shape Q ty Remote controller 1 Tapping screw M3 12 mm 2 Battery 2 Air cleaning filter 2 Cable tie 1 The following items are necessary to install this air conditioner The items are not included with th...

Страница 4: ... cannot reach the unit 6 INSTALLATION WORK 1 6 1 Installation dimensions Wall cap 50 1 15 16 or over 80 3 2 16 or over 100 3 15 16 or over 80 3 2 16 or over Unit mm in 150 5 14 16 or below from the floor Remote controller holder Tapping screw small Remote controller EMBEDDING THE INDOOR UNIT IN A WALL When installing a grating use a grating with narrow upper and lower horizontal bars so that the a...

Страница 5: ...RIGHT BOTTOM PIPING Unit mm in FOR LEFT BOTTOM PIPING 50 1 15 16 182 7 3 16 64 2 8 16 29 1 2 16 29 1 2 16 135 5 5 16 5 3 16 to 10 6 16 Fasten with vinyl tape Wall cap Wall pipe Field supplied Inside Wall Outside WARNING If the wall pipe is not used the wire interconnecting the indoor and outdoor units may touch metal and cause electric leakage 6 5 Forming piping 1 Pass the refrigerant pipe through...

Страница 6: ...stall the wall hook bracket so that it is correctly positioned horizontally and vertically If the wall hook bracket is tilted water will drip to the floor 2 Install the wall hook bracket so that it is strong enough to support the weight of the unit Fasten the wall hook bracket to the wall with 5 or more screws through the holes near the outer edge of the bracket Check that there is no rattle at th...

Страница 7: ...e that the piping is well insulated When the flare nut is tightened properly by your hand hold the body side coupling with a wrench then tighten with a torque wrench See following table for the flare nut tightening torques Wrench fixed Connection pipe Flare nut Indoor unit pipe Tighten with two wrenches Torque wrench Flare nut mm in Tightening torque N m kgf cm 6 35 1 4 dia 16 to 18 160 to 180 9 5...

Страница 8: ...it wire harness to the terminal Refer to the wiring diagram 4 Use the screws to install the cable clamper Lock nut Conduit holder Conduit connector 1 7 4 How to connect wiring to the terminals Caution when wiring cable When stripping off the insulation of a lead wire always use a special tool such as a wire stripper If there is no special tool available carefully strip the insulation with a knife ...

Страница 9: ... connect kit 11 1 Before install optional remote controller When you use optional remote controller some functions may not be used Please use the recommended optional remote controller CAUTION Before installing be sure to disconnect all power supply Don t touch the heat exchanger During installing or removing operation be sure not to have wire caught by parts or draw it hard Or it may result troub...

Страница 10: ...w to set the custom codes through the normal process refer to Remote control ler custom code 1 Press SET TEMP button to change the custom code between Match the code on the dis play to the air conditioner custom code initially set to If the custom code does not need to be selected press the MIN HEAT button and proceed to STEP 2 2 Press the MODE button and check that the indoor unit can receive sig...

Страница 11: ...itioner cannot receive a custom code if the air conditioner has not been set for the custom code 1 Press the START STOP button until only the clock is displayed on the remote controller display 2 Press the MODE button for at least five seconds to display the current custom code initially set to 3 Press the SET TEMP button to change the custom code between Match the code on the display to the air c...

Страница 12: ...ddle temp sensor error 5 1 Indoor unit fan motor error 5 3 Drain pump error 5 7 Damper error 5 15 Indoor unit error 6 2 Outdoor unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discharge temp sensor error 7 2 Compressor temp sensor error 7 3 Out...