7. FINISHING

(1) Insulate between pipes.
•  Overlap the connection pipe heat insulation and indoor unit pipe heat insulation.
•  Wrapping the connection pipe with cloth tape over the range within which they fit into 

the rear piping housing section.

•  Fasten the pipe bracket with the screw.
(2)  Fill the gap between the outside wall pipe hole and the pipe with sealer so that rain 

water and wind cannot blow in.

(3)  Fasten the drain hose to the outside wall, etc.

Cloth 
tape

Right side of 
pipe bracket

Wrap the each pipe 
with cloth tape

Pipe 
bracket

Screw

Wire

 

Left piping

 

For connection from the left rear

Connection cable

Drain hose

Pipe

Wall pipe

Connection cable

Drain hose

Connection 
pipe

 

Check the following:

GOOD

PROHIBITED

PROHIBITED

Accumulated 
drain water

No upward 
slope

50 mm or less from 
ground (earth)

Stopping 
downward

No upward 
slope

End of drain hose 
is immersed in 
water.

Drainage 
channel

Air

PROHIBITED

PROHIBITED

PROHIBITED

8. CUSTOMER GUIDANCE

Explain the following to the customer in accordance with the operation manual:
(1)  Starting and stopping method, operation switching, temperature adjustment, timer, 

airflow switching, and other remote controller operations.

(2)  Air filter removal and cleaning, and how to use the air louvers.
(3)  Give the operation manual to the customer.

9. ERROR CODES

If you use a wireless remote controller, the lamp on the photo detector unit will output error 
codes by way of blinking patterns. If you use a wired remote controller, error codes will ap-
pear on the remote control display. Refer to the lamp blinking patterns and error codes in 
the table. An error display is displayed only during operation.
The error code table contains errors irrelevant to this product as well.

 

Error display on the indoor unit

TIMER

LED1: 

TIMER Lamp 
(orange) 

LED2: 

OPERATION 
lamp (green) 

LED3: 

ECONOMY 
lamp (green) 

OPERATION

ECONOMY

 * : For wired remote controller (optional)

Error display

Error code*

Description

LED1

(orange)

LED2

(green)

LED3

(green)

(1)

(1)

11

Serial communication error

(2)

(1)

12

Wired remote controller 
communication error

(5)

(1)

15

Check run unfinished
Automatic airflow adjustment error

(6)

(1)

16

Peripheral unit transmission PCB 
connection error

(8)

(1)

18

External communication error

(1)

(2)

21

Unit number or Refrigerant circuit 
address setting error 
[Simultaneous multi-split type]

(2)

(2)

22

Indoor unit capacity error

(3)

(2)

23

Combination error

(4)

(2)

24

• Connection unit number 

error (indoor secondary unit) 
[Simultaneous multi-split type]

• Connection unit number error 

(indoor unit or branch unit) 
[Multi-split type]

(6)

(2)

26

Indoor unit address setting error

(7)

(2)

27

Primary unit, secondary unit setup 
error [Simultaneous multi-split 
type]

(9)

(2)

29

Connection unit number error in 
wired remote controller system

(1)

(3)

31

Power supply interruption error

(2)

(3)

32

Indoor unit PCB model 
information error

(3)

(3)

33

Indoor unit motor electricity 
consumption detection error

(5)

(3)

35

Manual auto switch error

(9)

(3)

39

Indoor unit power supply error for 
fan motor 

(10)

(3)

3A

Indoor unit communication circuit 
(wired remote controller) error

(1)

(4)

41

Room temp. sensor error 

(2)

(4)

42

Indoor unit heat ex. middle temp. 
sensor error

9378533080-04_IM.indb   13

9378533080-04_IM.indb   13

2022/2/14   15:13:15

2022/2/14   15:13:15

Содержание AGHG12KVCA

Страница 1: ...ut continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odour Keep any required ventilation openings clear of obstruction If the power cable or the connection cable is damaged it must be replaced by the manufacturer its service agent or similar qualified persons...

Страница 2: ...quipment being used is suitable for use with flam mable refrigerants i e nonsparking adequately sealed or intrinsically safe 2 4 Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts appropriate fire extinguishing equipment shall be available at hand Have a dry powder or CO2 fire extinguisher adjacent to the charging area 2 5 No ign...

Страница 3: ...ore carrying out this procedure it is essential that the technician is completely familiar with the equipment and all its details It is recommended good practice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to re use of reclaimed refrigerant It is essential that electrical power is ava...

Страница 4: ...be purchased separately Additional materials Connection pipe assembly Wall cap Connection cable 4 conductor Saddle Wall pipe Drain hose Decorative tape Tapping screws Vinyl tape Putty Sealant Refrigeration armored tape Insulated staples or clamps for connecting wire refer to your electrical cables Clamps or saddles to secure refrigerant pip ing Refrigeration lubricant 1 1 2 3 Pipe requirement CAUT...

Страница 5: ...ote control cable at least 1 m away from a television or radio receivers The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 1 m apart you could still receive noise under some signal conditions If children under 10 years old may approach the unit take preventive measures so that they cannot reach the unit When installing pipes shorter tha...

Страница 6: ...e top of the indoor unit on the indoor unit wall hook bracket 124 423 703 154 438 Unit mm WARNING Fix the indoor unit with 4 screws surely If improperly installed might cause to injury due to the toppling or falling Install the indoor unit at the place that has adequate strength Install the indoor unit so that the installed unit can withstand the weight of adult body weight If improperly installed...

Страница 7: ... from entering the pipes Die A Pipe B L Check if L is flared uniformly and is not cracked or scratched Pipe outside diameter mm in Dimension A mm Dimension B mm Flare tool for R32 clutch type 6 35 1 4 0 to 0 5 9 1 9 52 3 8 13 2 12 70 1 2 16 6 15 88 5 8 19 7 19 05 3 4 24 0 When using conventional flare tools to flare R32 pipes the dimension A should be approx imately 0 5 mm more than indicated in t...

Страница 8: ...cable clamp always fasten the cable at the plastic jacket portion but not at the insulator portion If the insulator is chafed electric leakage may occur Always connect the ground earth wire Improper earthing grounding work can cause electric shocks Do not use the ground earth screw for the indoor unit to the outdoor unit unless it is specified When the flare nut is tightened properly by your hand ...

Страница 9: ...ON WORK 4 1 Before install optional remote controller When you use optional remote controller some functions may not be used Please use the recommended optional remote controller CAUTION Before installing be sure to disconnect all power supply Don t touch the heat exchanger During installing or removing operation be sure not to have wire caught by parts or draw it hard Or it may result troubles to...

Страница 10: ...he following condition DC 12 V to 24 V 1 mA to 15 mA Operation behavior Input signal type Edge ON OFF When function setting is Operation Stop mode 1 Input signal Command OFF ON Operation ON OFF Stop When function setting is Forced stop mode Input signal Command OFF ON Forced stop ON OFF Normal When the forced stop is triggered indoor unit stops and Operation Stop operation by a remote controller i...

Страница 11: ...fore reconnecting it The function setting will not become active unless the power supply is disconnected and then reconnected 5 1 Function details Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room If the indication is not required select No indication 03 Factory setting Function num ber Settin...

Страница 12: ...s Error status Setting record Record any changes to the settings in the following table Function number Function setting Setting value 11 Filter sign 30 Room temperature control for indoor unit sensor Cooling 31 Heating 35 Room temperature control for wired remote controller sensor Cooling 36 Heating 40 Auto restart 42 Room temperature sensor switching 44 Remote controller custom code 46 External ...

Страница 13: ...d remote controller error codes will ap pear on the remote control display Refer to the lamp blinking patterns and error codes in the table An error display is displayed only during operation The error code table contains errors irrelevant to this product as well Error display on the indoor unit TIMER LED1 TIMER Lamp orange LED2 OPERATION lamp green LED3 ECONOMY lamp green OPERATION ECONOMY For wi...

Страница 14: ...otor 1 error Error display Error code Description LED1 orange LED2 green LED3 green 8 9 98 Outdoor unit fan motor 2 error 9 9 99 4 way valve error 10 9 9A Coil expansion valve error 1 10 A1 Discharge temp error 3 10 A3 Compressor temp error 4 10 A4 High pressure error 5 10 A5 Low pressure error 8 10 A8 Refrigerant leakage suspicion 11 10 AC Heat sink temp error 2 13 J2 Branch boxes error Multi spl...

Отзывы: