7. FINISHING
(1) Insulate between pipes.
• Overlap the connection pipe heat insulation and indoor unit pipe heat insulation.
• Wrapping the connection pipe with cloth tape over the range within which they fit into
the rear piping housing section.
• Fasten the pipe bracket with the screw.
(2) Fill the gap between the outside wall pipe hole and the pipe with sealer so that rain
water and wind cannot blow in.
(3) Fasten the drain hose to the outside wall, etc.
Cloth
tape
Right side of
pipe bracket
Wrap the each pipe
with cloth tape
Pipe
bracket
Screw
Wire
■
Left piping
■
For connection from the left rear
Connection cable
Drain hose
Pipe
Wall pipe
Connection cable
Drain hose
Connection
pipe
■
Check the following:
GOOD
PROHIBITED
PROHIBITED
Accumulated
drain water
No upward
slope
50 mm or less from
ground (earth)
Stopping
downward
No upward
slope
End of drain hose
is immersed in
water.
Drainage
channel
Air
PROHIBITED
PROHIBITED
PROHIBITED
8. CUSTOMER GUIDANCE
Explain the following to the customer in accordance with the operation manual:
(1) Starting and stopping method, operation switching, temperature adjustment, timer,
airflow switching, and other remote controller operations.
(2) Air filter removal and cleaning, and how to use the air louvers.
(3) Give the operation manual to the customer.
9. ERROR CODES
If you use a wireless remote controller, the lamp on the photo detector unit will output error
codes by way of blinking patterns. If you use a wired remote controller, error codes will ap-
pear on the remote control display. Refer to the lamp blinking patterns and error codes in
the table. An error display is displayed only during operation.
The error code table contains errors irrelevant to this product as well.
■
Error display on the indoor unit
TIMER
LED1:
TIMER Lamp
(orange)
LED2:
OPERATION
lamp (green)
LED3:
ECONOMY
lamp (green)
OPERATION
ECONOMY
* : For wired remote controller (optional)
Error display
Error code*
Description
LED1
(orange)
LED2
(green)
LED3
(green)
●
(1)
●
(1)
11
Serial communication error
●
(2)
●
(1)
12
Wired remote controller
communication error
●
(5)
●
(1)
15
Check run unfinished
Automatic airflow adjustment error
●
(6)
●
(1)
16
Peripheral unit transmission PCB
connection error
●
(8)
●
(1)
18
External communication error
●
(1)
●
(2)
21
Unit number or Refrigerant circuit
address setting error
[Simultaneous multi-split type]
●
(2)
●
(2)
22
Indoor unit capacity error
●
(3)
●
(2)
23
Combination error
●
(4)
●
(2)
24
• Connection unit number
error (indoor secondary unit)
[Simultaneous multi-split type]
• Connection unit number error
(indoor unit or branch unit)
[Multi-split type]
●
(6)
●
(2)
26
Indoor unit address setting error
●
(7)
●
(2)
27
Primary unit, secondary unit setup
error [Simultaneous multi-split
type]
●
(9)
●
(2)
29
Connection unit number error in
wired remote controller system
●
(1)
●
(3)
31
Power supply interruption error
●
(2)
●
(3)
32
Indoor unit PCB model
information error
●
(3)
●
(3)
33
Indoor unit motor electricity
consumption detection error
●
(5)
●
(3)
35
Manual auto switch error
●
(9)
●
(3)
39
Indoor unit power supply error for
fan motor
●
(10)
●
(3)
3A
Indoor unit communication circuit
(wired remote controller) error
●
(1)
●
(4)
41
Room temp. sensor error
●
(2)
●
(4)
42
Indoor unit heat ex. middle temp.
sensor error