Product Safety
Approvals /
Certification
RU has been tested by a Nationally Recognized Testing Laboratory (NRTL). A test report issued by
a NRTL shows compliance against UL 50E Ed. 1-2007, CAN/CSA-C22.2 NO. 94.2-07 and required
encapsulation class.
2.2.4
Electromagnetic Compatibility
Conducted Emission
Power Port
Unintentional radiation: CFR 47, Part 15B
Test mode: traffic mode
RET Port
Conducted emissions 3GPP 38.113
Test mode: traffic mode
Radiated Emission
Unintentional radiation
CFR 47, Part 15B
Test Standards
3GPP 38.113
Radio frequency radiation
exposure limits
CFR 47, Part 1.1310
Immunity Performance
Test standard
3GPP 38.113
Performance Criteria A
The Equipment Under Test (EUT) must continue to operate as intended during
and after test.
No degradation of performance or loss of functions.
Performance Criteria B
Temporary loss of function is allowed, provided the function is self-recoverable.
Radio must meet performance criteria before and after completion of test.
Immunity Specification
Table 6
Specification In 3GPP 38.113
Phenomenon
Application
Reference Standard
Detail
Specification
Criteria
RF electromagnetic field (80…
6000 MHz)
Enclosure
IEC 61000-4-3
Radiated Immunity
A
RU Hardware Feature
RU Specifications
25
Release 1.0
·
Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only