Philips screw driver
■
Power tools (optional)
■
Metric and SAE toolkit
Caution:
All power and cabling to the RU must be disconnected
from the RU before starting this procedure.
Attention:
Toute l'alimentation et le câblage doivent être
déconnectés de l'EF avant de commencer cette procédure.
Caution:
The RU is heavy. Fujitsu recommends removing the RU on
a two-person team to avoid damage to the unit or injury to the user.
Attention:
Le RU est lourd. Fujitsu recommande de retirer l'EF d'une
équipe de deux personnes pour éviter d'endommager l'appareil ou
des blessures à l'utilisateur.
Step 1
Attach both large crossmembers to the Wall Mounting Plate using 3/8-16 x 3.5L bolts, nuts, and flat washers as
shown in the following figure.
FNC00160
6_R
ev_01
Figure 16
Attach Large Crossmembers to Wall Mount Plate
Step 2
Secure the large crossmembers to the mounting plate until tightened using a 9/16 socket for the bolts and a 5/8
in. wrench for the nuts.
Step 3
Add jam nuts to each 3/8-16 x 3.5L bolts and secure until tightened.
Installation
RU Installation
100
Release 1.0
·
Issue 1.1, May 2021