Fujitsu Siemens Computers D1419 Скачать руководство пользователя страница 31

Glossary

A26361-D1419-Z120-1-7419

English - 23

Glossary

The technical terms and abbreviations given below represent only a selection of the full list of
common technical terms and abbreviations.
Not all technical terms and abbreviations listed here are valid for the described mainboard.

ACPI

Advanced Configuration and
Power Management Interface

ISA

Industrial Standard Architecture

AC'97

Audio Codec '97

LAN

Local Area Network

AGP

Accelerated Graphics Port

LSA

LAN Desk Service Agent

AMR

Audio Modem Riser

MCH

Memory Controller Hub

AOL

Alert On LAN

MMX

MultiMedia eXtension

APM

Advanced Power Management

NMI

Non Maskable Interrupt

ATA

Advanced Technology
Attachment

P64H

PCI64 Hub

BIOS

Basic Input Output System

PCI

Peripheral Component
Interconnect

CAN

Controller Area Network

PXE

Preboot eXecution Environment

CPU

Central Processing Unit

RAID

Redundant Array of Inexpensive
Disks

CNR

Communication Network Riser

RAM

Random Access Memory

C-RIMM

Continuity Rambus Inline
Memory Module

RAMDAC

Random Access Memory Digital
Analogue Converter

DIMM

Dual Inline Memory Module

RDRAM

Rambus Dynamic Random
Access Memory

ECC

Error Correcting Code

RIMM

Rambus Inline Memory Module

EEPROM

Electrical Erasable
Programmable Read Only
Memory

RSB

Remote Service Board

FDC

Floppy disk controller

RTC

Real Time Clock

FIFO

First-In First-Out

SB

Soundblaster

FSB

Front Side Bus

SDRAM

Synchronous Dynamic Random
Access Memory

FWH

Firmware Hub

SGRAM

Synchronous Graphic Random
Access Memory

GMCH

Graphics and Memory Controller
Hub

GPA

Graphics Performance
Accelerator

SIMD

Streaming Mode Instruction
(Single Instruction Multiple Data)

I

2

C

Inter Integrated Circuit

SMBus

System Management Bus

IAPC

Instantly Available Power
Managed Desktop PC Design

SVGA

Super Video Graphic Adapter

ICH

I/O Controller Hub

USB

Universal Serial Bus

IDE

Intelligent Drive Electronics

VGA

Video Graphic Adapter

IPMB

Intelligent Platform Management
Bus

WOL

Wake On LAN

IPMI

Intelligent Platform Management
Interface

ZCR

Zero Channel RAID

IPSEC

Internet Protocol Security

Содержание D1419

Страница 1: ...Technisches Handbuch Technical Manual Mainboard D1419 Deutsch English 2...

Страница 2: ...ionen zu unseren Produkten Tipps Updates usw finden Sie im Internet http www fujitsu siemens com Are there any technical problems or other questions you need clarified Please contact your sales partne...

Страница 3: ......

Страница 4: ...pier recycl Este manual ha sido impreso sobre papel reciclado Questo manuale stato stampato su carta da riciclaggio Denna handbok r tryckt p recyclingpapper Dit handboek werd op recycling papier gedru...

Страница 5: ...Mainboard D1419 Technisches Handbuch Technical Manual Deutsch English Ausgabe M rz 2003 March 2003 edition...

Страница 6: ...erteilung oder GM Eintragung Lieferm glichkeiten und technische nderungen vorbehalten Copyright Fujitsu Siemens Computers GmbH 2003 Intel is a registered trademark of Intel Corporation USA PS 2 is a r...

Страница 7: ...tion program 9 Activating and Configuring Host RAID 10 Default Settings in the menu Configure View SCSI Controller Settings 11 SCSI Bus Interface Definitions 12 Additional Options 12 SCSI Device Confi...

Страница 8: ......

Страница 9: ...e Bar at this point This symbol indicates that you must press the Enter key Text in this typeface indicates screen outputs Text in this bold typeface indicates the entries you make via the keyboard Te...

Страница 10: ...d conductors on it please take great care when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the main...

Страница 11: ...one 64 bit PCI slot with 33 MHz long design possible SCSI controller AIC7902 Ultra 320 capable two channel board supports Zero Channel RAID with Host RAID function Screen controller ATI Rage XL VGA o...

Страница 12: ...3 Power supply ATX 4 PC98 5 Power supply 12 V 6 Fan connector for CPU 0 7 Fan connector for CPU 1 8 Control panel 9 USB ports 2 3 10 IDE drives primary 11 IDE drives secondary 12 IPMB 13 Connector NM...

Страница 13: ...ure measurement of the system temperature with an onboard temperature sensor measurement of the ambient temperature with a temperature sensor Fan monitoring Fans that are no longer available blocked o...

Страница 14: ...ng diode 1 2 1 Orange green indicator 2 Green indicator Green LAN activity Orange green LAN speed off 10 Mbit s or no connection Green 100 Mbit s Orange 1 Gbit s ISA bus resources Device IRQ Address D...

Страница 15: ...PCI to PCI bridge can use several PCI interrupts INTA INTB INTC INTD Monofunctional PCI boards default only use one PCI interrupt INTA per PCI slot The PCI interrupts INTA INTB INTC and INTD are avail...

Страница 16: ...t of the PCI controller Interrupts of SCSI channel A respective B LAN interrupts are not PCI specific Screen resolution Depending on the operating system used the screen resolutions in the following t...

Страница 17: ...default settings This function is not possible in all menus Starting the SCSI Host RAID configuration program Start the PC if the following message appears press the key combination Ctrl and A Press...

Страница 18: ...RAID with the entry Enable Host RAID Support Now the existing SCSI hard disks and already configured RAID drives are displayed Select one of the displayed hard disks and configure the RAID System to...

Страница 19: ...er Sync Transfer Rate MB Sec 320 Packetized Yes QAS Yes Initiate wide negotiation Yes Enabled Enable disconnection Yes Enabled Send Start Unit Command Yes BIOS Multiple LUN Support No Include in BIOS...

Страница 20: ...the SCSI controller must be enabled The default setting is Enabled The terminating resistor of the SCSI controller is enabled With F6 you can reset to the default setting Additional Options Master SC...

Страница 21: ...e SCSI controller attempts 16 bit data transfer Wide negotiation instead of 8 bit data transfer As a result two byte are transferred simultaneously via the SCSI bus instead of one byte Enable disconne...

Страница 22: ...n still invoke the SCSI configuration program by pressing CTRL and A at system bootup Extended Int 13 Translation for DOS Drives 1Gbyte The default setting is Enabled Normally only drives with a capac...

Страница 23: ...more errors occur Support Removable Disks under Int 13 as Fixed Disks This option allows you to use removable media drives such as CD ROM drives without installing additional drivers The default sett...

Страница 24: ...tection is enabled in BIOS Setup in Security menu the Password field must be set to Enabled on The password query is skipped Passwords are deleted off The password query is effective default setting W...

Страница 25: ...at LED blinking BMC is activated 4 PCI slot 1 5 PCI slot 2 6 PCI slot 3 Zero Channel RAID 7 PCI slot 4 8 PCI slot 5 9 LED L3 red Processor configuration error 10 LED L2 green Operating voltage 11 LED...

Страница 26: ...available LED L3 red Processor configuration error off on processor configuration error LED L4 amber Global error indicator off on prefailure detected flashing global error LED L5 blue identification...

Страница 27: ...u are installing the heat sink you must ensure a good heat contact between heat sink and the processor s surface It is essential to use heat conducting paste between the processor and the heat sink If...

Страница 28: ...connector on the mainboard Upgrading main memory The slots for the main memory are suitable for 256 512 1024 and 2048 Mbyte DDR DIMM memory modules The organization in three memory banks 0 to 2 enable...

Страница 29: ...ders on each side of the memory slot outwards Insert the memory module in the slot while folding the side holders up until the memory module engages 2 Removing a memory module 1 1 Push the clips on th...

Страница 30: ...ithium battery may be replaced only with an identical battery or with a type recommended by the manufacturer Do not throw lithium batteries into the household waste They must be disposed of in accorda...

Страница 31: ...AM Random Access Memory C RIMM Continuity Rambus Inline Memory Module RAMDAC Random Access Memory Digital Analogue Converter DIMM Dual Inline Memory Module RDRAM Rambus Dynamic Random Access Memory EC...

Страница 32: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochte...

Отзывы: