Fujitsu Siemens Computers D1419 Скачать руководство пользователя страница 17

Features

A26361-D1419-Z120-1-7419

English - 9

SCSI/Host RAID configuration utility

The BIOS of the onboard U320 SCSI controller includes a menu-driven SCSI/Host RAID
configuration program. This program allows you to change almost all of the option settings of the
SCSI controller.

When you boot the system a SCSI/Host RAID-BIOS message listing the SCSI devices connected is
displayed.

i

If an SCSI/Host RAID-BIOS error message appears or problems arise with SCSI devices,
please read the documentation of your SCSI device.

If you are unable to trace or rectify the error, please contact your dealer or our customer
service centre.

Working with the keyboard

Use the following keys when running the program:

ËÊ

to make selections

Ú

 

to accept a selection

[ESC]

 

to call the previous menu and to terminate the SCSI configuration program.

[F6]

 

to reset to the default settings. This function is not possible in all menus.

Starting the SCSI/Host RAID configuration program

Ê

 

Start the PC, if the following message appears, press the key combination 

[Ctrl]

 and 

[A]

 :

Press <Ctrl> <A> for SCSI Select (TM) Utility!

In the first menu the available U320 SCSI controller are displayed. The onboard SCSI controller of
D1419 is displayed with the following entry:

AIC-7902 at slot 00 00:04:00

When choosing

 the AIC-7902 you are taken to the top level of the configuration menu of this

controller. The following options cannot be displayed.

Host RAID is disabled (default):

C

onfigure/View SCSI Controller Settings

SCSI Disk Utilities

Enable Host RAID Support

Host RAID is enabled:

C

onfigure/View SCSI Controller Settings

Configure/View Host RAID Settings

SCSI Disk Utilities

Disable Host RAID Support

Terminating the SCSI/Host RAID configuration program

Depending on the current menu level, you can display the previous menu by pressing the 

[ESC]

key. If you have made changes in the current menu you will be prompted to store them.

Содержание D1419

Страница 1: ...Technisches Handbuch Technical Manual Mainboard D1419 Deutsch English 2...

Страница 2: ...ionen zu unseren Produkten Tipps Updates usw finden Sie im Internet http www fujitsu siemens com Are there any technical problems or other questions you need clarified Please contact your sales partne...

Страница 3: ......

Страница 4: ...pier recycl Este manual ha sido impreso sobre papel reciclado Questo manuale stato stampato su carta da riciclaggio Denna handbok r tryckt p recyclingpapper Dit handboek werd op recycling papier gedru...

Страница 5: ...Mainboard D1419 Technisches Handbuch Technical Manual Deutsch English Ausgabe M rz 2003 March 2003 edition...

Страница 6: ...erteilung oder GM Eintragung Lieferm glichkeiten und technische nderungen vorbehalten Copyright Fujitsu Siemens Computers GmbH 2003 Intel is a registered trademark of Intel Corporation USA PS 2 is a r...

Страница 7: ...tion program 9 Activating and Configuring Host RAID 10 Default Settings in the menu Configure View SCSI Controller Settings 11 SCSI Bus Interface Definitions 12 Additional Options 12 SCSI Device Confi...

Страница 8: ......

Страница 9: ...e Bar at this point This symbol indicates that you must press the Enter key Text in this typeface indicates screen outputs Text in this bold typeface indicates the entries you make via the keyboard Te...

Страница 10: ...d conductors on it please take great care when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the main...

Страница 11: ...one 64 bit PCI slot with 33 MHz long design possible SCSI controller AIC7902 Ultra 320 capable two channel board supports Zero Channel RAID with Host RAID function Screen controller ATI Rage XL VGA o...

Страница 12: ...3 Power supply ATX 4 PC98 5 Power supply 12 V 6 Fan connector for CPU 0 7 Fan connector for CPU 1 8 Control panel 9 USB ports 2 3 10 IDE drives primary 11 IDE drives secondary 12 IPMB 13 Connector NM...

Страница 13: ...ure measurement of the system temperature with an onboard temperature sensor measurement of the ambient temperature with a temperature sensor Fan monitoring Fans that are no longer available blocked o...

Страница 14: ...ng diode 1 2 1 Orange green indicator 2 Green indicator Green LAN activity Orange green LAN speed off 10 Mbit s or no connection Green 100 Mbit s Orange 1 Gbit s ISA bus resources Device IRQ Address D...

Страница 15: ...PCI to PCI bridge can use several PCI interrupts INTA INTB INTC INTD Monofunctional PCI boards default only use one PCI interrupt INTA per PCI slot The PCI interrupts INTA INTB INTC and INTD are avail...

Страница 16: ...t of the PCI controller Interrupts of SCSI channel A respective B LAN interrupts are not PCI specific Screen resolution Depending on the operating system used the screen resolutions in the following t...

Страница 17: ...default settings This function is not possible in all menus Starting the SCSI Host RAID configuration program Start the PC if the following message appears press the key combination Ctrl and A Press...

Страница 18: ...RAID with the entry Enable Host RAID Support Now the existing SCSI hard disks and already configured RAID drives are displayed Select one of the displayed hard disks and configure the RAID System to...

Страница 19: ...er Sync Transfer Rate MB Sec 320 Packetized Yes QAS Yes Initiate wide negotiation Yes Enabled Enable disconnection Yes Enabled Send Start Unit Command Yes BIOS Multiple LUN Support No Include in BIOS...

Страница 20: ...the SCSI controller must be enabled The default setting is Enabled The terminating resistor of the SCSI controller is enabled With F6 you can reset to the default setting Additional Options Master SC...

Страница 21: ...e SCSI controller attempts 16 bit data transfer Wide negotiation instead of 8 bit data transfer As a result two byte are transferred simultaneously via the SCSI bus instead of one byte Enable disconne...

Страница 22: ...n still invoke the SCSI configuration program by pressing CTRL and A at system bootup Extended Int 13 Translation for DOS Drives 1Gbyte The default setting is Enabled Normally only drives with a capac...

Страница 23: ...more errors occur Support Removable Disks under Int 13 as Fixed Disks This option allows you to use removable media drives such as CD ROM drives without installing additional drivers The default sett...

Страница 24: ...tection is enabled in BIOS Setup in Security menu the Password field must be set to Enabled on The password query is skipped Passwords are deleted off The password query is effective default setting W...

Страница 25: ...at LED blinking BMC is activated 4 PCI slot 1 5 PCI slot 2 6 PCI slot 3 Zero Channel RAID 7 PCI slot 4 8 PCI slot 5 9 LED L3 red Processor configuration error 10 LED L2 green Operating voltage 11 LED...

Страница 26: ...available LED L3 red Processor configuration error off on processor configuration error LED L4 amber Global error indicator off on prefailure detected flashing global error LED L5 blue identification...

Страница 27: ...u are installing the heat sink you must ensure a good heat contact between heat sink and the processor s surface It is essential to use heat conducting paste between the processor and the heat sink If...

Страница 28: ...connector on the mainboard Upgrading main memory The slots for the main memory are suitable for 256 512 1024 and 2048 Mbyte DDR DIMM memory modules The organization in three memory banks 0 to 2 enable...

Страница 29: ...ders on each side of the memory slot outwards Insert the memory module in the slot while folding the side holders up until the memory module engages 2 Removing a memory module 1 1 Push the clips on th...

Страница 30: ...ithium battery may be replaced only with an identical battery or with a type recommended by the manufacturer Do not throw lithium batteries into the household waste They must be disposed of in accorda...

Страница 31: ...AM Random Access Memory C RIMM Continuity Rambus Inline Memory Module RAMDAC Random Access Memory Digital Analogue Converter DIMM Dual Inline Memory Module RDRAM Rambus Dynamic Random Access Memory EC...

Страница 32: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochte...

Отзывы: