
Add-on modules
18 - English
A26361-D1419-Z120-1-7419
LEDs
Normal operation
Another operating mode
Heartbeat LED (flashes):
"BMC is activated"
(indicates that the
system monitoring
function is active)
flashing
on/off: BMC is not working
LED L1 (yellow):
"Auxiliary voltage“
on
off: no auxiliary voltage available
LED L2 (green):
"Operating voltage“
on
off: no operating voltage available
LED L3 (red):
"Processor configuration
error“
off
on: processor configuration error
LED L4 (amber): Global
error indicator
off
on: prefailure detected
flashing: global error
LED L5 (blue):
identification display
off
on: Device identification
PCI slots 1, 2, 3 and 4 are 3.3 V slots. PCI slot 3 supports a Zero Channel RAID controller.
The RSB can be mounted in PCI slot 5.
Slot sequence
•
A "Zero Channel RAID Controller" board can only be mounted in PCI slot 3 to offer a RAID
solution with the onboard RAID controller.
•
A 5 V PCI card can only be mounted in PCI slot 5.
Содержание D1419
Страница 1: ...Technisches Handbuch Technical Manual Mainboard D1419 Deutsch English 2...
Страница 3: ......
Страница 8: ......