Always turn off the power or unplug the power cord from
the outlet before attempting to replace the fuse.
Failing to turn off the power may lead to electrical shocks.
⑥ Replacing the fuse
If the ON lamp does not light up when the POWER
(power switch) is turned on,and the VIS SETTER
does not operate, then the fuse is probably blown.
Replace it as follows:
1) Open the upper cover and remove the front cover.
2)Remove the screws on the left side cover and
ください。
take off the cover.
3) Replace the fuse (3A) that is on the main board.
※ Note: Fuse is 125V / 3A (5.2 dia × 20)
⑦When escapement is clogged with debris
【When screws are clogged in escape body
through hole】
1) Turn off the power switch, and adjust the air
pressure to 0 MPa with the adjuster handle on the
air unit while checking the pressure
gauge on the front panel.
2) Poke a narrow rod or pin through the pipe fitting
取付ボルトをゆるめてパイプ接手を取り外し、
into the debris or loosen the installation bolt(1),
異物を除去してください。
remove the pipe fitting , and remove the debris.
【When the R-L finger is clogged】
1)Turn off the power switch, and set the air pressure
to 0 MPa with the adjuster handle on the air unit
while checking the pressure gauge on the
front panel.
2)Loosen the screws (1) and remove the Es cover.
Loosen the screw (2) and remove the R finger.
3)Grip the Es plate and move right and left to remove
the debris.(Using tweezers may be helpful.)
4)When reassembling, be sure the front and rear of the
Es cover faces in the correct direction.The side
with the engraved mark is the front side.
WARNING
<
Main board
>
F1 fuse(3A)
Adjuster
handle
Increase
Decrease
Bolt
Pipe fitting
Engraved mark
Screw
②
Screw
①
Es cover
R finger
Es plate