5.Pre-operating setup
5-1.How to install
1) Install at a position 200 to 250 mm higher than the
location where the screws are supplied and
be careful not to twist or forcibly bend
the feed hose.
2) Prepare a stand block for use during installation
and set so that the rubber feet of the feeder unit
are on the stand block.
Installing directly without using a stand block will
cause a drastic bend in the screw feed hose.
5-2.Installing the wiring and piping
Always connect to ground line. Failure to connect
to ground may cause elecrical shocks.
1) Connect the ground terminal on the rear panel to
ground by using a ground wire.
2) Then connect power supply cord to a powers supply.
3)Connect the air hose to the factory air source.
(or air compressor.)
The air hose fitting is the φ8
The source air pressure cannot be adjusted on this
unit,so adjust the factory source air pressure to a
range wihtin 0.4 to 0.5 MPa.
4) If using the air screwdriver,connect the air
screwdriver hose to the φ8 fitting
on the front panel of the feeder.
5) Connect the screw feed signal plug (from external
section) to the receptacle (3P) on the front panel of
the feeder.
6) Install the screw feed hose on to the escapement.
CAUTION
Rubber feet
Stand
Ground
AC outlet
Factory
air
0.4
~
0.5MPa
When using air driver
screw
screw feed
hose
0.4
~
0.5MPa
Factory air
source
When using air driver
AC outlet
Ground