8-16
8.2 Scanner Section
3) Menu 0345 “Optical Axis Adjustment”
4) Menu 0346 “Optical Magnification Calibration”
5) Menu 0347 “Focus Calibration”
6) Menu 0321 “Focus Position Adjustment”
7) Menu 0349 “LED Light Amount Adjustment”
8) Menu 0420 “Mask Position Adjustment”
9) Scanner Correction (Ore-operational Check)
Removal
1. Remove the CCD unit
2. Remove the shaft, shutter and lock washer.
3. Remove the shaft and the drive gear.
Installation
Installation is essentially in the reverse order of
removal.
8.2.10
Shutter/Gear Replacement
Z
2
141
Shaft
Drive Gear
Shaft
Shutter
Lock Washer