5.5 Carrier Adjustment/Maintenance (04)
On this menu, the feeding amount for the fixed
feeding mode of the 135 films can be adjusted.
[Selection]
[Setup and Maintenance]
→
[04 Carrier Adjustment/
Maintenance]
→
[0400 NC100AY Fixed Feeding
Setup]
1. Set up fixed feed frame lengths for the 135 full and
half sizes by clicking the [
▼
] and [
▲
] buttons.
2. Click the [Regist.] button.
3. Click the [Close] button.
• Operation returns to the menu screen.
This menu is used to adjust mask position relative to
the monitor screen and prints.
This menu should be executed for all carriers and
masks to be used.
[Selection]
[Setup and Maintenance]
→
[04 Carrier Adjustment/
Maintenance]
→
[0420 Mask Position Adjustment]
1. Install the film carrier and mask to be adjusted.
• The carrier ID, carrier type and mask type are
displayed.
NOTE: • Set a mount frame without film when adjusting
the mount mask.
• Do not insert a film.
5.5.1
NC100AY Fixed Feeding Setup (0400)
Initial Value Input Range
135F 38.10mm
36.00 to 40.00mm
135H 19.40mm
19.00 to 20.00mm
5.5.2
Mask Position Adjustment (0420)