For Safe Operation

1

DR-ID 1200PB Operation Manual    

897N120972A

CAUTIONS

Install the system in accordance with what is provided by IEC 60601-1:2005 + A1:2012 Chapter 

16. Contact our official dealer or FUJIFILM Representative for installation (except the flat panel 

sensor) of the system.

CAUTIONS

Do not hit or drop the equipment. Otherwise, injury or damage to images, etc. may result.

CAUTIONS

Be sure to inspect the system periodically.

To assure optimum performance of the equipment, it is necessary to systematically perform 

maintenance and inspection. For information on maintenance and inspection, contact our 

official dealer or FUJIFILM Representative.

CAUTIONS

Do not perform maintenance and inspection while the equipment is used for a patient.

CAUTIONS

The institution where the equipment is installed is responsible for its use and maintenance.

In addition, this equipment should not be used by persons other than doctors or suitably

trained staff.

Contraindications and Prohibitions

No contraindications present.

Classification

●   According to the type of protection against electrical shock

  Class 1 equipment

●  According to the degree of protection against electrical shock

  No applied part

●  According to the degree of protection against harmful ingress of water

 IP00

●   According to the degree of safety of application in the presence of a flammable anesthetics 

mixture with air or with oxygen or nitrous oxide.

   Equipment not suitable for use in the presence of a flammable anesthetics mixture with air or with 

oxygen or nitrous oxide. 

●  According to the mode of operation

  CONTINUOUS OPERATION

Содержание DR-ID 1200PB

Страница 1: ...Manual and other manuals for the related products before actually operating the power box After reading this manual store it nearby the power box so that you can see it whenever necessary For Safe Ope...

Страница 2: ...ii DR ID 1200PB Operation Manual 897N120972A...

Страница 3: ...not supplied by FUJIFILM Corporation 5 FUJIFILM Corporation shall not be liable for malfunctions and damages resulting from remodeling maintenance and repair using repair parts other than those specif...

Страница 4: ...iv DR ID 1200PB Operation Manual 897N120972A...

Страница 5: ...anel Sensor Connector 3 1 3 1 3 Changing the Direction of the Flat Panel Sensor Connector 3 2 3 1 4 Checking the Connection between the Flat Panel Sensor and the Connector 3 2 3 2 Starting Up and Shut...

Страница 6: ...vi DR ID 1200PB Operation Manual 897N120972A...

Страница 7: ...system Otherwise fire or electric shock may occur due to the electrical load exceeding the allowable limit WARNING Observe the following precautions when using the cables Do not touch the plug and co...

Страница 8: ...equipment are long be careful not to entangle the cables during use Also be careful not to trip over the cables Falls could result in injury CAUTIONS Follow the specified procedure when turning off t...

Страница 9: ...le produit En cas d endommagement de l quipement suite une chute ou un impact Installation Precautions CAUTIONS Do not install the equipment in a location with the following conditions Where the tempe...

Страница 10: ...Addition of devices Removal of devices Update of devices Upgrade of devices Warnings and Cautions on Network WARNING Make sure to use the optional parts and networks recommended by us Failure to use...

Страница 11: ...ns WARNING Confirm that the respiratory density of disinfectant including solvent is under legal regulation Certain disinfectants may damage health When using a disinfectant follow instructions suppli...

Страница 12: ...inspection while the equipment is used for a patient CAUTIONS The institution where the equipment is installed is responsible for its use and maintenance In addition this equipment should not be used...

Страница 13: ...DR ID 1200 The products in can be installed in patient environment Only one flat panel sensor can be connected to one power box in wired communication mode Up to three power boxes can be used for one...

Страница 14: ...product to a HUB and connect an additional LAN cable via the HUB 2 3 Locations of Labels and Signs Locations of labels and signs affixed to the DR ID 1200PB and the relevant safety signs are shown bel...

Страница 15: ...ase contact our official dealer or FUJIFILM Representative Year of manufacture Refer to Instruction Manual Booklet 2 3 3 Symboles de s curit et autres Les symboles de s curit suivants sont utilis s su...

Страница 16: ...2 4 System Configuration Product Overview 2 DR ID 1200PB Operation Manual 897N120972A...

Страница 17: ...sensors are used make sure that the READY lamp among the status lamps of the flat panel sensor to be used for an exposure is lit Connect Disconnect the connector straight to the flat panel sensor If c...

Страница 18: ...the connector of the SE cable to the flat pane sensor check the power ON OFF state and communication state with the status LEDs on flat panel sensor POWER Blue The power on off state of the flat pane...

Страница 19: ...hat the READY status lamp on the flat panel sensor is lit 3 2 3 Shutting Down the DR ID 1200PB 1 Disconnect the SE connector from the flat panel sensor and then disconnect the power cable of the power...

Страница 20: ...3 4 Basic Operation 3 DR ID 1200PB Operation Manual 897N120972A...

Страница 21: ...best conditions 4 1 1 Periodical Inspection Inspection Every Three Months Once every three months remove any dirt or dust accumulated in each part of the equipment using a vacuum cleaner or air duste...

Страница 22: ...4 2 Daily Inspection and Maintenance 4 DR ID 1200PB Operation Manual 897N120972A...

Страница 23: ...Humidity 15 RH 15 C 80 RH 30 C no dew condensation Atmospheric pressure 700hPa 1060hPa 2 Non operating Conditions Environmental conditions under which power can be supplied Temperature 5 C 35 C Humid...

Страница 24: ...below Specifications dimensions and weight are subject to change for improvement without prior notice A 2 1 DR ID 1200PB Width mm in Depth mm in Height mm in Weight kg lb Power box 259 10 2 205 8 1 2...

Страница 25: ...when this product is used in an examination car For the external view see O 1 1 Retaining Bracket for PB page O 1 O 1 1 Retaining bracket for PB The retaining bracket for PB is an optional item This...

Страница 26: ...O 2 Appendix O Use of Optional Items DR ID 1200PB Operation Manual 897N120972A...

Страница 27: ...peration Manual 897N120972A Maintenance and Inspection 1 Maintenance and Inspection Items Assigned to Specified Dealer For periodical inspection of the equipment and necessary arrangements consult our...

Страница 28: ...FUJIFILM MEDICAL SYSTEMS U S A INC 419 WEST AVENUE STAMFORD CT 06902 U S A...

Отзывы: