16
INZ-TN5A0506-E
6.2 Reading Read-Only Word Data [Function Code: 04
H
]
Function code
Max. number of words
to read in one message
Relative address
{Register No.
Contents
0000 to 0081
30001 to 30079
Internal data
1000 to 1049
31001 to 31044
Error history data
2000 to 2049
32001 to 32044
Alarm history data
04
H
64
words
3000 to 3049
33001 to 33044
Operation history data
(1) Composition of message
Command message composition (byte)
Response message composition (byte)
Station
No. Station
No.
Function
code Function
code
Upper
Readout byte number
Readout word number × 2
Readout start number
(Relative address)
Lower
Upper
Upper
Contents of the first
word data
Lower
Readout Word number
Lower
1 to 60
Upper
Upper
Contents of the next
word data
Lower
CRC data
Lower
Upper
Contents of the last
word data
Lower
Upper
CRC data
Lower
Arrangement of read-out word data
MSB LSB
Upper byte of contents of the first word data
Lower byte of contents of the first word data
Upper byte of contents of the next word data
Lower byte of contents of the next word data
Upper byte of contents of the last word data
Lower byte of contents of the last word data
(2) Description
of
functions
Word data of continuous word numbers from the read-out start No. can be read. Read-out word data are
transmitted from the slave station in the order of upper and lower bytes.
~
~
~ ~