1.6 Product Guarantee 

The product guarantee term is one year after installation or two years after manufacturing on the nameplate, whichever 

expires first. 

However, the guarantee will not apply in the following cases, even if the guarantee term has not expired. 
 
(1)    The cause includes incorrect usage or inappropriate repair or modification. 
(2)  The product is used outside the standard specified range. 
(3)  The failure is caused by dropping, damage or breakage during transportation after the purchase. 
(4)  The cause is earthquake, fire, storm or flood, lightening, excessive voltage, or other types of disaster or secondary 

disasters. 

 

 

2 Specifications 

 

2.1 Storage Environment 

 

2.1.1 Temporary 

Storage 

Store the option card in an environment that satisfies the requirements listed in Table 2.1. 

Table 2.1    Environmental Requirements for Storage and Transportation 

Item Requirements 

Storage 

Temperature 

*1

 

-25 to 70

°

 

Relative 

humidity 

5 to 95% 

*2

 

Location where the option card is not subject to abrupt changes in 

temperature that would result in the formation of condensation or ice. 

Atmosphere 

The inverter must not be exposed to dust, direct sunlight, corrosive or flammable gases, oil mist, 

vapor, water drops or vibration. The atmosphere must contain only a low level of salt. 

(0.01 mg/cm

2

 or less per year) 

86 to 106 kPa (in storage) 

Atmospheric 

pressure 

70 to 106 kPa (during transportation) 

 
*1 

Assuming a comparatively short storage period (e.g., during transportation or the like)

   

*2 

Even if the humidity is within the specified requirements, avoid such places where the option card will be subjected to 

sudden changes in temperature that will cause condensation to form.   

 

Precautions for temporary storage 

(1) Do not leave the inverter directly on the floor. 
(2) If the environment does not satisfy the specified requirements, wrap the option card in an airtight vinyl sheet or the like 

for storage. 

(3) If the option card is to be stored in an environment with a high level of humidity, put a drying agent (such as silica gel) in 

the airtight package described in item (2).

 

2.1.2 Long-term 

Storage 

The long-term storage methods for the inverter vary largely according to the environment of the storage site. General 

storage methods are described below. 
(1) The storage site must satisfy the requirements specified for temporary storage. 

(2) The inverter must be stored in a package that is airtight to protect it from moisture. Include a drying agent inside the 

package to maintain the relative humidity inside the package to within 70%. 

(3) If the option card has been installed in the equipment or control board at a construction site where it may be subjected to 

humidity, dust or dirt, then remove the option card and store it in a suitable environment specified in Table 2.1. 

Содержание OPC-LM1-PS1

Страница 1: ...lly operate the equipment Read this instruction manual and understand the description before installing connecting wiring operating or performing maintenance and inspection of the option Keep this ins...

Страница 2: ...card with wet hands otherwise accident or electric shock may occur No foreign matter such as screws metal patches lint chips and dust in the option card There is risk of fire or accident Do not damag...

Страница 3: ...Terminal Function and Specifications 8 2 5 Control Specifications 8 3 Applicable Encoder 9 3 1 Specifications of Applicable Encoder 9 3 2 Encoder Installation and Signal 9 4 Wiring 10 4 1 Wiring Leng...

Страница 4: ...etails refer to the Multi function Keypad Instruction Manual INR SI47 1092 E Use the FRENIC Loader option for the FRENIC Lift and click the System monitor tab on the Operation Status Monitor window Fo...

Страница 5: ...G Turn off the power and wait for at least five minutes before starting installation Further check that the LED monitor is unlit and check that the DC link bus voltage between the P and N terminals is...

Страница 6: ...the four spacers and CN1 on the back of the OPC LM1 PS1 into the spacer holes and connector CN1 on the control circuit board in the inverter Visually check that the spacers and CN1 are firmly inserted...

Страница 7: ...m2 or less per year 86 to 106 kPa in storage Atmospheric pressure 70 to 106 kPa during transportation 1 Assuming a comparatively short storage period e g during transportation or the like 2 Even if th...

Страница 8: ...he inverter must not be subjected to sudden changes in temperature that will cause condensation to form Altitude 1 000 m max Note Vibration 3 mm Max amplitude 2 to 9 Hz 9 8 m s2 9 to 20 Hz 2 m s 2 20...

Страница 9: ...put frequency Max 50 kHz Differential input signal PA PA PB PB 0 6V to 1 2V CK Communication clock non inverting CK Communication clock inverting Clock transmission DT Communication data non inverting...

Страница 10: ...oder Encoder power supply Encoder model HEIDENHAIN ECN1313 or its equivalent 3 2 Encoder Installation and Signal The encoder shall rotate in the direction shown in Figure 3 1 when terminal FWD is ON E...

Страница 11: ...is 10 m or more PA green black A PA yellow black A PB blue black B PB red black B CK purple CLOCK CK yellow CLOCK DT gray DATA DT pink DATA Wiring of the option card and the encoder The wiring of the...

Страница 12: ...coder in the specification voltage of encoder There is a risk of failure L1 R L2 S L3 T U V W M CK DT DT FRN LM1S G OPC LM1 PS1 PA PB PB CK PO PA PO CM CM Encoder FPA FPB CM CM User Controller Figure...

Страница 13: ...oder L36 ASR P Constant at high speed 2 0 It is necessary to adjust L38 ASR P Constant at low speed 2 0 It is necessary to adjust 5 2 Procedure of Magnetic Pole Position Offset Tuning You have to exec...

Страница 14: ...the FWD key starts tuning The EXECUTING is displayed on the monitor of the MFKP during the tuning The EXECUTING disappears indicating that it is the end of tuning The L03 data automatically returns to...

Страница 15: ...3 2 Adjust the following parameters to eliminate vibration and the rollback becomes small The following table shows the tendency to the phenomenon by setting of the parameter Function Code Code Settin...

Страница 16: ...ed inverter unbalanced load compensation works correctly Using analog speed command Time 0 ON FWD Release Brake Reference speed pre ramp Lift controller output F24 F23 Time 0 Reference speed final Act...

Отзывы: