3.  Description 

In comparison to the standard powers applies the MCA-series offers a threesomes higher current/voltage range. The 
power is limited to the maximum value. Power supplies of the series MCA will be delivered in 19" table-top cases, 
depending on type. Rack adapters for table-top units are available as accessories. 

3.1  Front Panel, Controls 

 

Figure: 

Front panel of a MCA 750 

– 1500 unit. The dimensions of devices with higher power are different to this type.  

Mains Power Switch. Provides two pole 
isolation from mains network 

13 

current display: 
flashing: set value is displayed 
non flashing: actual value is displayed 

Output release. No mains disconnection. 

14  indicates control state 

C

onstant 

V

oltage CV 

Output release status. 
Indicates controller and output active. 

15  indicates control state 

C

onstant 

C

urrent CC 

(Option) Selects control between LOCAL and 
REMOTE 

16  switches display to set value 

(Option) Selects control between 
REMOTE/ANALOGUE and REMOTE/DIGITAL 

17 

Potentiometer for voltage set value limitation 
(adjustable only with a tool) 

6,7,8  (Option) Indicates the active control input 

18  indicates active voltage set value limitation 

(Option) indicates Data traffic on digital 
interface 

19 

indicates overtemperature 
(ambient temperature too high, fan failed or dusty) 

10 

lockable Potentiometer for voltage set value 

20  (Option) indicates control state power limitation 

11 

lockable Potentiometer for current set value 

21  Operating range of MCA units 

12 

voltage display: 
flashing: set value is displayed 
non flashing: actual value is displayed 

 

 

Содержание MCA 3000

Страница 1: ...MCA Series power classes up to 9000W certified according to ISO 9001 2008 Operating Instructions This instruction is only dedicated to electrical experts and people with a suitable technical education...

Страница 2: ...l Controls 6 3 2 Rear side Connections 7 3 3 Assembly 7 3 4 Mode of operation 8 4 Operation with local controls 9 5 Maintenance 10 6 Options 11 6 1 Analog Programming 11 6 1 1 Directly Connected Analo...

Страница 3: ...rent Labeled by a sticker on the rear At a high leakage current is an earth connection to the Earth stud mandatory Operating environment The units may only be operated in a clean dry environment Pleas...

Страница 4: ...The output current is only limited by internal safety resistors and can reach 500 x the nominal value Load Types The type of load is not critical All passive bipolar loads can be connected Power Limi...

Страница 5: ...ut out is used characteristics C or K Return Current Flow The return current must not flow via the mains earth The screen of a HV cable is always connected to earth Only in some cases it may be used f...

Страница 6: ...2 Output release No mains disconnection 14 indicates control state Constant Voltage CV 3 Output release status Indicates controller and output active 15 indicates control state Constant Current CC 4...

Страница 7: ...current 3 mounting place for optional analog programming 4 mounting place for optional interface Probus V i e IEEE 488 RS232 USB LAN 5 Positive high voltage output socket 6 Negative 0V connector inter...

Страница 8: ...asuring voltage on the monitor terminals Voltage limitation The voltage set value can be limited by a potentiometer on the front panel The limitation is always active independent of the operation mode...

Страница 9: ...this the LED V LIMIT is on and the limitation voltage is displayed on the left display If you wish no limitation simply turn the potentiometer 17 clockwise to it s limit LED V LIMIt goes off Turn vol...

Страница 10: ...th standard power supplies with equal power The power supply can operate with full nominal voltage and about 1 3 nominal current or full nominal current and about 1 3 nominal voltage Other values corr...

Страница 11: ...eference pins 0V pin 6 and 9 for all external programming voltages are connected to the 0V output terminal A At an open connection to 0V earth the programming can float up to 300 V Please make sure th...

Страница 12: ...quires the wiring of the current control and vice versa The reference voltage 10V or the set value voltages can be supplied by some other sources i e PLC or PC plug in cards 0V must be connected The U...

Страница 13: ...front panel 3 I MON AA Actual output current monitor signal 0 10V represents 0 nominal current Ri ca 10k Ri ca 2k Ri ca 11k 4 VPS AA Slider Voltage Pot on front panel 0 10V for 0 nom Voltage Ri ca 10...

Страница 14: ...the moment interface converters are available for the following bus systems USB IEEE 488 LAN Ethernet RS232 RS422 RS485 Profibus CANopen Analog 0 10V Features short form Probus V provides commands to...

Страница 15: ...d At 3000V nominal voltage it is positive or negative see indication on the front panel The 0V terminal is intern fix connected to earth Output Isolation At units up to 400V nominal voltage each outpu...

Страница 16: ...separately Please don t exchange together because the front panel would not be fixed Is the power supply only be used as plug in unit the stands may be removed For that remove the bottom sheet The sta...

Отзывы: