7.  Technical Data 

All here stated data are valid for voltage and current control in internal operation. 

Changes of the technical data with the options analog and digital programming see corresponding sections. 

AC - Input 

230V ±10%  47 - 63 Hz    or     400V ±10%  3phasig  47 - 63 Hz, depending on  
the type, see type label. Overvoltage category II according to IEC664. 
N-connection and PE (non fused earth) always necessary!  
For devices with high leakage current required PEN 

At plug-type connections:   performance according to 
 

- IEC 60320-C14 until 700W 

 

- IEC 60320-C19 700W until 1400W 

 

- Cable connect (Three Phase Current) 

EMC Standards 

See Certificate of Conformity. 

Safety 

See Certificate of Conformity.

 

Environment Conditions 

Operating room:

 

Only for indoor usage (see section 2.1.) 

Temperature:

 

0 °C  to  40 °C 

Air humidity:

 

Max. relative humidity 80% until 31

 

ºC,  

 

linear decreasing until 50% relative humidity at 40 ºC 

Atm press:

 

Altitude max. 2000 m over sea level 

Contamination:

 

Protection Class

 

IP20 

Output Voltage / Current 

See front panel of the power supply. 

Power Limitation 

Depending on type, the output power is limited to  750W / 1500W or 3000W.

 

Output Polarity

 

Up to 1500V

 nominal voltage it is floating (each output terminal may get earthed) 

At 3000V

 nominal voltage it is positive or negative (see indication on the front panel). 

The „0V“ terminal is intern fix connected to earth.

 

Output Isolation 

At units

 up to 400V

 nominal voltage each output terminal may get  

max. ±500V

,  

at 750V max ± 1000V and at 1500V

  

max. ±2000V

 with respect to earth. 

 

 

Attention ! 

Not valid for units with "analog programming", see section 6.1.1 

Setting Range Voltage 

With Potentiometer 

VOLTAGE 

appr. 0,1% to 100% from nominal value 

Current 

 

With Potentiometer 

CURRENT 

appr.

 

0,1% to 100% from nominal value 

Reproducibility 

±1x10

-3

 from nominal value,  

Setting Resolution 

With potentiometer on the front panel  1x10

-4

 from nominal value 

Residual Ripple  

<2x10

-4

 pp +200mVpp from nominal value 

Deviation 

<±1x10

-5

 from nominal value, for ±10% mains voltage variation 

<5x10

-4

 from nominal value, for 0 to 100% load variation 

<±2x10

-4

 from nominal value, over 8 hours 

<±1x10

-4

/K from nominal value 

Recovery Time 

voltage control

 

<1ms for load variations from 10% to 100% or 100% to 10% 

current control

 

<10ms for load variations causing an output voltage variation less than 10% of the 
nominal voltage. 

Discharging Time Constant

  at unloaded output 

max. 10 sec 

Programming speed: 

<300ms for changes of output voltage from 10% to 90% resp. 90% to 10% 

Volage and Current Display 

DVM for voltage and current, extent ±20000 Digits 

Status Display 

LEDs for constant voltage, constant current, set value limitation active, setting of 
programming switch, Output ON, overtemperature, power limitation

 

Mechanical size 

Depending on type, changes reserved.

 

 

Содержание MCA 3000

Страница 1: ...MCA Series power classes up to 9000W certified according to ISO 9001 2008 Operating Instructions This instruction is only dedicated to electrical experts and people with a suitable technical education...

Страница 2: ...l Controls 6 3 2 Rear side Connections 7 3 3 Assembly 7 3 4 Mode of operation 8 4 Operation with local controls 9 5 Maintenance 10 6 Options 11 6 1 Analog Programming 11 6 1 1 Directly Connected Analo...

Страница 3: ...rent Labeled by a sticker on the rear At a high leakage current is an earth connection to the Earth stud mandatory Operating environment The units may only be operated in a clean dry environment Pleas...

Страница 4: ...The output current is only limited by internal safety resistors and can reach 500 x the nominal value Load Types The type of load is not critical All passive bipolar loads can be connected Power Limi...

Страница 5: ...ut out is used characteristics C or K Return Current Flow The return current must not flow via the mains earth The screen of a HV cable is always connected to earth Only in some cases it may be used f...

Страница 6: ...2 Output release No mains disconnection 14 indicates control state Constant Voltage CV 3 Output release status Indicates controller and output active 15 indicates control state Constant Current CC 4...

Страница 7: ...current 3 mounting place for optional analog programming 4 mounting place for optional interface Probus V i e IEEE 488 RS232 USB LAN 5 Positive high voltage output socket 6 Negative 0V connector inter...

Страница 8: ...asuring voltage on the monitor terminals Voltage limitation The voltage set value can be limited by a potentiometer on the front panel The limitation is always active independent of the operation mode...

Страница 9: ...this the LED V LIMIT is on and the limitation voltage is displayed on the left display If you wish no limitation simply turn the potentiometer 17 clockwise to it s limit LED V LIMIt goes off Turn vol...

Страница 10: ...th standard power supplies with equal power The power supply can operate with full nominal voltage and about 1 3 nominal current or full nominal current and about 1 3 nominal voltage Other values corr...

Страница 11: ...eference pins 0V pin 6 and 9 for all external programming voltages are connected to the 0V output terminal A At an open connection to 0V earth the programming can float up to 300 V Please make sure th...

Страница 12: ...quires the wiring of the current control and vice versa The reference voltage 10V or the set value voltages can be supplied by some other sources i e PLC or PC plug in cards 0V must be connected The U...

Страница 13: ...front panel 3 I MON AA Actual output current monitor signal 0 10V represents 0 nominal current Ri ca 10k Ri ca 2k Ri ca 11k 4 VPS AA Slider Voltage Pot on front panel 0 10V for 0 nom Voltage Ri ca 10...

Страница 14: ...the moment interface converters are available for the following bus systems USB IEEE 488 LAN Ethernet RS232 RS422 RS485 Profibus CANopen Analog 0 10V Features short form Probus V provides commands to...

Страница 15: ...d At 3000V nominal voltage it is positive or negative see indication on the front panel The 0V terminal is intern fix connected to earth Output Isolation At units up to 400V nominal voltage each outpu...

Страница 16: ...separately Please don t exchange together because the front panel would not be fixed Is the power supply only be used as plug in unit the stands may be removed For that remove the bottom sheet The sta...

Отзывы: