6.2  Digital Interface PROBUS V (Option) 

The flexible Interface System Probus V consists of two parts, that communicate over a 
fiber optic connection. 

 

Unit ADDAT30 (short “ADDA”) is an AD/DA interface that controls the power 
supply. ADDA is connected to an interface converter via fiber optics. ADDA is 
located as a plug on module on the power supply electronics. It is accessible 
after opening the left side panel of the housing. 

 

The interface converter that connects ADDA to different bus-systems,  is 
located at the back panel of the power supply. 
It can also be operated outside the power supply. In that case, the outside 
connection is fiber optic and therefore, a maximum of EMC ruggedness can 
be achieved. 

At the moment, interface converters are available for the following bus-systems: 

 

USB 

 

IEEE-488 

 

LAN (Ethernet) 

 

RS232 

 

RS422 

 

RS485 

 

Profibus 

 

CANopen 

 

Analog 0..10V 

Features (short form)

 

“Probus V” provides commands to set output voltage, output current and to switch the 
output voltage. 
Set values can be ramped with defined speed. 
High resolution read back of actual values. 

Programming speed

 

Up to 2000 set values per second possible. (depending on the interface converter)

 

Select Digital Interface

 

Set switch (4) to REMOTE. 
If the power supply is additionally equipped with an “analog programming” option, set 
also switch (5) to DIGITAL. 
LED DIGITAL (8) indicates digital programming selected 

Status indication

 

LED BUSY (9) flashes on data traffic. 

Voltage limitaion

 

The voltage set value limitation is always active. Adjustable with Potentiometer V-
LIMIT (17) on the front panel. 

Further Information

 

A detailed description of the Probus V system (command set, driver installation etc.) is 
provided in separate manuals that come along with Probus V.

 

 

 

Содержание MCA 3000

Страница 1: ...MCA Series power classes up to 9000W certified according to ISO 9001 2008 Operating Instructions This instruction is only dedicated to electrical experts and people with a suitable technical education...

Страница 2: ...l Controls 6 3 2 Rear side Connections 7 3 3 Assembly 7 3 4 Mode of operation 8 4 Operation with local controls 9 5 Maintenance 10 6 Options 11 6 1 Analog Programming 11 6 1 1 Directly Connected Analo...

Страница 3: ...rent Labeled by a sticker on the rear At a high leakage current is an earth connection to the Earth stud mandatory Operating environment The units may only be operated in a clean dry environment Pleas...

Страница 4: ...The output current is only limited by internal safety resistors and can reach 500 x the nominal value Load Types The type of load is not critical All passive bipolar loads can be connected Power Limi...

Страница 5: ...ut out is used characteristics C or K Return Current Flow The return current must not flow via the mains earth The screen of a HV cable is always connected to earth Only in some cases it may be used f...

Страница 6: ...2 Output release No mains disconnection 14 indicates control state Constant Voltage CV 3 Output release status Indicates controller and output active 15 indicates control state Constant Current CC 4...

Страница 7: ...current 3 mounting place for optional analog programming 4 mounting place for optional interface Probus V i e IEEE 488 RS232 USB LAN 5 Positive high voltage output socket 6 Negative 0V connector inter...

Страница 8: ...asuring voltage on the monitor terminals Voltage limitation The voltage set value can be limited by a potentiometer on the front panel The limitation is always active independent of the operation mode...

Страница 9: ...this the LED V LIMIT is on and the limitation voltage is displayed on the left display If you wish no limitation simply turn the potentiometer 17 clockwise to it s limit LED V LIMIt goes off Turn vol...

Страница 10: ...th standard power supplies with equal power The power supply can operate with full nominal voltage and about 1 3 nominal current or full nominal current and about 1 3 nominal voltage Other values corr...

Страница 11: ...eference pins 0V pin 6 and 9 for all external programming voltages are connected to the 0V output terminal A At an open connection to 0V earth the programming can float up to 300 V Please make sure th...

Страница 12: ...quires the wiring of the current control and vice versa The reference voltage 10V or the set value voltages can be supplied by some other sources i e PLC or PC plug in cards 0V must be connected The U...

Страница 13: ...front panel 3 I MON AA Actual output current monitor signal 0 10V represents 0 nominal current Ri ca 10k Ri ca 2k Ri ca 11k 4 VPS AA Slider Voltage Pot on front panel 0 10V for 0 nom Voltage Ri ca 10...

Страница 14: ...the moment interface converters are available for the following bus systems USB IEEE 488 LAN Ethernet RS232 RS422 RS485 Profibus CANopen Analog 0 10V Features short form Probus V provides commands to...

Страница 15: ...d At 3000V nominal voltage it is positive or negative see indication on the front panel The 0V terminal is intern fix connected to earth Output Isolation At units up to 400V nominal voltage each outpu...

Страница 16: ...separately Please don t exchange together because the front panel would not be fixed Is the power supply only be used as plug in unit the stands may be removed For that remove the bottom sheet The sta...

Отзывы: