8.  Calibration 

Certificate of Calibration

 

All guaranteed data for our power supplies are tested in the factory and documented 
in an internal test protocol. Furthermore we offer within the scope of our  
ISO 9001 : 2008

 

certified quality system a calibration in our plant. The customer 

receives a certificate of calibration. We certify the output data and the compliance with 
our catalog data. 
The blue calibration sticker refers to the next recommended date of calibration. 

Subsequent Calibration 

Generally we recommend an annual subsequent calibration. 

9.  Certificate of Conformity 

The power supplies carry the CE-sign. Please read the Certificate of Conformity. 

10.  Accessories 

Connectors, Cables  

See enclosed Mounting Instructions 

Mounting instructions 

Rack Adapter

 

 

Attention! Before opening the power supply, disconnect from mains!

 

The front panel handles must be exchanged separately. (Please don’t exchange 
together, because the front panel would not be fixed).  
Is the power supply only be used as plug-in unit, the stands may be removed.  
For that remove the bottom sheet. The stands can be removed by using a screwdriver 
for recessed-head screws. Then place back the bottom sheet. 

Caution!! 

After removing the stands, the power supply may not longer be used as a table-top 
unit, because no convection cooling is possible, risk for overheating. 

11.  Warranty, Repairs 

Your power supply has been assembled and tested under stringent quality assurance 
procedures. 

We provide a 2 years warranty, commencing with the delivery date stated in the 
serial number. 

This warranty does not cover misuse or attempted repair by untrained personnel. 
Enclosed you will find one set of circuit diagrams for service purposes. 
In all further enquiries for service or spare parts, please provide both the model and 
serial number of the unit 

12.  Special Models, Modifications 

Power Supplies that are equipped with special modifications are identified with "MOD" 
within the type designator (i.e. MCA 750

 

 1500 MOD) on the label at the rear panel . 

Please refer to the separate data sheet attached. 

Содержание MCA 3000

Страница 1: ...MCA Series power classes up to 9000W certified according to ISO 9001 2008 Operating Instructions This instruction is only dedicated to electrical experts and people with a suitable technical education...

Страница 2: ...l Controls 6 3 2 Rear side Connections 7 3 3 Assembly 7 3 4 Mode of operation 8 4 Operation with local controls 9 5 Maintenance 10 6 Options 11 6 1 Analog Programming 11 6 1 1 Directly Connected Analo...

Страница 3: ...rent Labeled by a sticker on the rear At a high leakage current is an earth connection to the Earth stud mandatory Operating environment The units may only be operated in a clean dry environment Pleas...

Страница 4: ...The output current is only limited by internal safety resistors and can reach 500 x the nominal value Load Types The type of load is not critical All passive bipolar loads can be connected Power Limi...

Страница 5: ...ut out is used characteristics C or K Return Current Flow The return current must not flow via the mains earth The screen of a HV cable is always connected to earth Only in some cases it may be used f...

Страница 6: ...2 Output release No mains disconnection 14 indicates control state Constant Voltage CV 3 Output release status Indicates controller and output active 15 indicates control state Constant Current CC 4...

Страница 7: ...current 3 mounting place for optional analog programming 4 mounting place for optional interface Probus V i e IEEE 488 RS232 USB LAN 5 Positive high voltage output socket 6 Negative 0V connector inter...

Страница 8: ...asuring voltage on the monitor terminals Voltage limitation The voltage set value can be limited by a potentiometer on the front panel The limitation is always active independent of the operation mode...

Страница 9: ...this the LED V LIMIT is on and the limitation voltage is displayed on the left display If you wish no limitation simply turn the potentiometer 17 clockwise to it s limit LED V LIMIt goes off Turn vol...

Страница 10: ...th standard power supplies with equal power The power supply can operate with full nominal voltage and about 1 3 nominal current or full nominal current and about 1 3 nominal voltage Other values corr...

Страница 11: ...eference pins 0V pin 6 and 9 for all external programming voltages are connected to the 0V output terminal A At an open connection to 0V earth the programming can float up to 300 V Please make sure th...

Страница 12: ...quires the wiring of the current control and vice versa The reference voltage 10V or the set value voltages can be supplied by some other sources i e PLC or PC plug in cards 0V must be connected The U...

Страница 13: ...front panel 3 I MON AA Actual output current monitor signal 0 10V represents 0 nominal current Ri ca 10k Ri ca 2k Ri ca 11k 4 VPS AA Slider Voltage Pot on front panel 0 10V for 0 nom Voltage Ri ca 10...

Страница 14: ...the moment interface converters are available for the following bus systems USB IEEE 488 LAN Ethernet RS232 RS422 RS485 Profibus CANopen Analog 0 10V Features short form Probus V provides commands to...

Страница 15: ...d At 3000V nominal voltage it is positive or negative see indication on the front panel The 0V terminal is intern fix connected to earth Output Isolation At units up to 400V nominal voltage each outpu...

Страница 16: ...separately Please don t exchange together because the front panel would not be fixed Is the power supply only be used as plug in unit the stands may be removed For that remove the bottom sheet The sta...

Отзывы: