FuG Elektronik GmbH, Am Eschengrund 11, D - 83135 Schechen 

 

File: MCA Rev_3 Englisch.docx  

Rev 3 

3 von 16 

Adhere strictly to the operating instructions before you either change
switches, or connect sockets, marked with this symbol!

Symbol for high Voltage outputs

Symbol for cassis earth, potential safety earth

1.  Safety Instructions 

The units of the series MCA deliver dangerously High Voltages! Ensure that 
nothing, and nobody, will be endangered by this High Voltage before putting the 
unit into operation! 

Attention ! 

The full dielectric strength of the high voltage connectors is only achieved if 
fully mated together. 

Before Commissioning

 

Make sure that you have read and understood the operating instruction manual! 
Ensure that you observe all the hints and warnings contained within it. In not following 
the operating instructions, you contravene the safety regulations for operating units of 
this type. FuG accepts no liability for consequences arising from the failure to follow 
these safety instructions. 

Mains voltage 

Check whether the input voltage for your power supply, noted on the type label, 
corresponds to your actual mains voltage. 

Earth 

The unit is provided with a safety earth (German safety class I). For protection against 
electric shocks, the unit must be connected to the mains via a suitable 3 or 5-pole 
cable with a non-fused earth conductor. 
For electrical potential equalization to the load, and to the center of the AC-supply, the 
earth stud must be used. 

High leakage current! 

Labeled by a sticker on the rear. At a high leakage current is an earth connection to 
the Earth stud mandatory.

 

Operating environment 

The units may only be operated in a clean, dry environment.  
Please make sure that no objects or liquids can enter the casing through the 
ventilating apertures. 
Because of the risk of sparks, the unit must not be operated in the vicinity of 
flammable gases or fumes. 

Cooling

 

To ensure a adequate cooling, the ambient temperature must not exceed 

40°C

This unit is air cooled by convection or at units >800J/s by forced ventilation.  
Therefore , please ensure an adequate air-flow is available, and ensure that nothing is 
placed either above or below the unit which may impede this air-flow. 
Don’t operate table top units without the mounted legs. 
Do not expose the unit directly to solar radiation.  
If the unit is used as a plug-in component, sufficient air-flow must be provided,  
(1HU = 44,5 mm above and below clear).  

Opening the unit 

Before opening, ensure that the unit is disconnected from the mains!

 

The unit may be opened by operating personnel only for the purpose of operating 
switches as described in the operating instructions, (e.g. baud rate switch of Probus V, 
which is inside).

 

Danger: 

The electronic boards inside the power supply are connected to one output 
pole. During operation, the electronic boards lie on up to 2000V. 

ATTENTION! 

The unit contains capacitors, which discharge only very slowly (typical 
discharge time 5 min) or, in worst case, do not discharge at all. 

For switch over

 

use isolated tools only. 

Maintenance or repair of this unit should only be carried out by trained service 
personnel who are aware of the inherent dangers of such equipment. 

Symbols

 

 

 

Содержание MCA 3000

Страница 1: ...MCA Series power classes up to 9000W certified according to ISO 9001 2008 Operating Instructions This instruction is only dedicated to electrical experts and people with a suitable technical education...

Страница 2: ...l Controls 6 3 2 Rear side Connections 7 3 3 Assembly 7 3 4 Mode of operation 8 4 Operation with local controls 9 5 Maintenance 10 6 Options 11 6 1 Analog Programming 11 6 1 1 Directly Connected Analo...

Страница 3: ...rent Labeled by a sticker on the rear At a high leakage current is an earth connection to the Earth stud mandatory Operating environment The units may only be operated in a clean dry environment Pleas...

Страница 4: ...The output current is only limited by internal safety resistors and can reach 500 x the nominal value Load Types The type of load is not critical All passive bipolar loads can be connected Power Limi...

Страница 5: ...ut out is used characteristics C or K Return Current Flow The return current must not flow via the mains earth The screen of a HV cable is always connected to earth Only in some cases it may be used f...

Страница 6: ...2 Output release No mains disconnection 14 indicates control state Constant Voltage CV 3 Output release status Indicates controller and output active 15 indicates control state Constant Current CC 4...

Страница 7: ...current 3 mounting place for optional analog programming 4 mounting place for optional interface Probus V i e IEEE 488 RS232 USB LAN 5 Positive high voltage output socket 6 Negative 0V connector inter...

Страница 8: ...asuring voltage on the monitor terminals Voltage limitation The voltage set value can be limited by a potentiometer on the front panel The limitation is always active independent of the operation mode...

Страница 9: ...this the LED V LIMIT is on and the limitation voltage is displayed on the left display If you wish no limitation simply turn the potentiometer 17 clockwise to it s limit LED V LIMIt goes off Turn vol...

Страница 10: ...th standard power supplies with equal power The power supply can operate with full nominal voltage and about 1 3 nominal current or full nominal current and about 1 3 nominal voltage Other values corr...

Страница 11: ...eference pins 0V pin 6 and 9 for all external programming voltages are connected to the 0V output terminal A At an open connection to 0V earth the programming can float up to 300 V Please make sure th...

Страница 12: ...quires the wiring of the current control and vice versa The reference voltage 10V or the set value voltages can be supplied by some other sources i e PLC or PC plug in cards 0V must be connected The U...

Страница 13: ...front panel 3 I MON AA Actual output current monitor signal 0 10V represents 0 nominal current Ri ca 10k Ri ca 2k Ri ca 11k 4 VPS AA Slider Voltage Pot on front panel 0 10V for 0 nom Voltage Ri ca 10...

Страница 14: ...the moment interface converters are available for the following bus systems USB IEEE 488 LAN Ethernet RS232 RS422 RS485 Profibus CANopen Analog 0 10V Features short form Probus V provides commands to...

Страница 15: ...d At 3000V nominal voltage it is positive or negative see indication on the front panel The 0V terminal is intern fix connected to earth Output Isolation At units up to 400V nominal voltage each outpu...

Страница 16: ...separately Please don t exchange together because the front panel would not be fixed Is the power supply only be used as plug in unit the stands may be removed For that remove the bottom sheet The sta...

Отзывы: