Peak and Hold PRO Injector Driver
Pre-crank detection:
This option can be used when the minimum time for
injector detection is equal to or greater than the map time under idle condition.
The test is performed every time the module is turned on before the first
injection pulse.
If the engine is started before the test is finished the message
“Injectors test
not run”
will be displayed on the ECU screen.
Testing is recommended only in cases where the automatic test does not work.
To activate, mark the check box “Enabled” and define the test time in
milliseconds.
IMPORTANT
This time is the pulse size that the P&H PRO Injector
Driver will apply to the injector, so it should be as small
as possible in order to avoid opening the injector and,
consequently, injecting fuel with the engine off