Peak and Hold PRO Injector Driver
7.1 Configuration screen index
•
Output Configuration:
efine the channels in use and set Peak and
Hold current.
Channel:
Check the boxes for the channels that are in use.
Actuation:
Set the cylinder number wired to that channel.
Preset:
Select Peak and Hold current from the options. Selecting
“
Custom
” allows typing Peak and Hold current.
•
Current limits
Peak min and max: 2A/12A
Hold min and max: 0.5A/3A
•
Safety protections:
Select the protection level desired.
•
Serial number:
Allows selecting a serial number and call it “Driver A”
or “Driver B”.
•
Top right panel:
The buttons at the top right are for reading, writting and
ereasing the driver setup.
•
Information:
Some info is available at this screen, such as Hardware
and software version, as well as the driver serial number.