FT500 SFI / FT500LITE SFI
72
Diagram with FT dual valve block
1
1
2
2
1
2
3
4
5
10
6
7
8
Max
30cm
9
14
15
16
7
8
NOTE:
The pressure sensor (7) must be connected to the top
of the wastegate with a hose (8) with a maximum
length of 1ft. It prevents damage to the pressure
sensor caused by vibration.
IMPORTANT:
-
The pressure sensor must be installed on
an exclusive line, and not shared with any other
connection, to avoid reading errors.
-
For the correct operation of the system, use
only FuelTech PS sensors line: PS-150, PS-300, etc.
IMPORTANT:
Use a PS150 pressure sensor connected to any white
input. Setup as “Wastegate pressure”.
Other functions
Set the outputs of the increase and decrease solenoid valves.
NOTE:
It is recommended to use the yellow or blue outputs
for connecting the solenoids.
IMPORTANT:
Avoid using different color outputs for solenoids. Use
two yellow outputs or two blue outputs.
In datalogger you can configure the channels for monitoring
BoostController pressure.
Set the input for the pressure sensor as PS-10B, PS-20B, PS-150
and PS-300 or BoostController2 MAP. In FTManager access the menu
“sensors and calibration/inputs”.
FTManager setting
Through FTManager you can make all settings required for the
operation of BoostController.