Curtis-Toledo Rotary Compressor
CAP862
Operations and Maintenance Manual
Chapter 7 Page 3
High Temperature Shutdown
a.
Elevated ambient temperature.
b.
Low sump oil level.
c.
Plugged oil filter.
d.
Restricted cooling airflow.
e.
Clogged heat exchanger.
f.
Thermal bypass is leaking
g.
Faulty high air temperature switch.
h.
Delivery pressure set too high.
i.
Panels are open.
j.
Exhaust air is restricted.
High power consumption
a.
Plugged separator.
b.
Plugged aftercooler.
c.
Improper air pressure switch setting.
d.
Too low of a line voltage.
e.
Electrical phase imbalance.
f.
Imminent motor failure.
g.
Imminent air end failure
h.
Belt slippage
i.
Loose electrical connection
Safety valve discharges
a.
Over pressure switch not set correctly.
b.
Inlet valve not closing properly in relation to
air demand.
c.
Plugged separator.
d.
Faulty minimum pressure check valve.
e.
Faulty safety valve.
f.
Incorrect set point on safety valve