Curtis-Toledo Rotary Compressor
CAP862
Operations and Maintenance Manual
Chapter 5 Page 2
3. Inspect the oil level after 10 minutes of shutdown. The Oil level could read lower during operation.
C During operation
1.
Shutdown the compressor if abnormal noise or vibration is observed.
2. Do not loosen any screws or open any control valve during operation.
Warning: Failure to do so may cause injury.
3. Make sure condensed water comes out of the after cooler and water separator. Moisture is not wanted
in the system.
4. Record voltage: current, discharge pressure, discharge temperature, oil level and inspect gauges
periodically during operation for future reference.
D Storage
In some cases it may be necessary to store the compressor for extended periods of several months before
placing the unit in operation. When this is required do the following:
1. Cover and seal all machine openings to prevent the entrance of water and dirt.
2. Cover all openings in open drip proof motors to prevent the entrance of rodents.
3. If the storage conditions are below freezing, drain off the after cooler, traps, water-cooled
heat exchangers and attendant piping. It is not recommend for outside storage.