1-15
Symptom
Potential Cause
Diagnosis
Basket lift fails to work
•
Failed
fuse
•
Failed
computer.
•
Failed or loose wiring.
•
Failed basket lift relay.
•
Failed
motor.
•
Replace 15-amp fuse
•
With basket lift up, check
for 27-33VDC at pin 10 of
15-pin plug. Zero volts if
basket lift is down. No
voltage: computer has
failed.
•
With basket lift up, check
for 27-33VDC (Zero
voltage if basket lift is
down) at basket lift relay
terminal. None or
improper voltage: check
for loose or corroded
wiring.
•
With basket lift up, is line
voltage present at the NC
(lower) terminal of basket
lift microswitch (middle
terminal with basket lift
down)? This suggests a
bad relay.
•
With basket lift up, is line
voltage present at the
common position of the
microswitch. This
suggests a failed motor.