Frymaster Pasta Magic 17/8BC Скачать руководство пользователя страница 20

5-3 

5.3 

Annual/Periodic System Inspection

  

 

This appliance should be inspected and adjusted periodically by qualified service personnel as 
part of a regular kitchen maintenance program. 

 

Frymaster recommends that this appliance be inspected at least annually by a Factory 
Authorized Service Technician as follows:

 

 

Rethermalizer 

 

 

Inspect the cabinet inside and out, front and rear for excessive moisture 

 

 

Verify that the heating element wires are in good condition and that leads have no visible fraying 
or insulation damage and that they are free of moisture. 

 

 

Verify that heating elements are in good condition.  Inspect the elements for signs of extensive 
dry-firing. 

 

 

Verify the heating-element amp-draw is within the allowed range as indicated on the appliance’s 
rating plate. 

 

 

Verify that the temperature and high-limit probes are properly connected, tightened and 
functioning properly, and that mounting hardware and probe guards are present and properly 
installed. 

 

 

Verify that component box and contactor box components (i.e. computer/controller, relays, 
interface boards, transformers, contactors, etc.) are in good condition and free from oil and other 
debris. 

 

 

Verify that component box and contactor box wiring connections are tight and that wiring is in 
good condition. 

 

 

Verify that all safety features (i.e. contactor shields, drain safety switches, reset switches, etc.) 
are present and functioning properly. 

 

 

Verify that the vat is in good condition and free of leaks and that the frypot insulation is in 
serviceable condition.   

 

 

Verify that all wiring harnesses and connections are tight and in good condition. 

 

Содержание Pasta Magic 17/8BC

Страница 1: ...Visit our website for the latest manual Part Number FRY_IOM_8196889 01 2021 8196889 Original Instructions CAUTION READ THE INSTRUCTIONS BEFORE USING THE FRYER Keep these instructions for future refere...

Страница 2: ...alled See NATIONAL CODE REQUIREMENTS in Chapter 2 of this manual for specifics NOTICE TO U S CUSTOMERS This equipment is to be installed in compliance with the basic plumbing code of the Building Offi...

Страница 3: ...e management operational procedures DANGER Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit A restraint kit...

Страница 4: ...arly qualified person in order to avoid a hazard WARNING Operation installation and servicing of this product may expose you to chemicals products including Bisphenol A BPA glass wool or ceramic fiber...

Страница 5: ...e Claim Procedure 1 4 CHAPTER 2 Installation Instructions 2 1 General Installation Requirements 2 1 2 2 Caster Leg Installation 2 2 2 3 Pre Connection Preparations 2 2 2 4 Connection to the Electrical...

Страница 6: ...contacting your local FAS Distributor Information may also be obtained by calling the Frymaster Technical Service Department at 1 800 551 8633 or 1 318 865 1711 When requesting service please have th...

Страница 7: ...ice on Frymaster equipment must be performed by qualified certi fied licensed and or authorized installation or service personnel as defined in Section 1 5 1 5 Definitions QUALIFIED AND OR AUTHORIZED...

Страница 8: ...l responsibility for safe delivery upon acceptance of the equip ment for transport What to do if your equipment arrives damaged 1 File a claim for damages immediately regardless of the extent of damag...

Страница 9: ...essly ap proved by the party responsible for compliance could void the user s authority to operate the equip ment Frymaster computers have been tested and found to comply with the limits for a Class A...

Страница 10: ...its so equipped on the lift rods located at the top rear of the cabinet so that the basket lift rollers guides the lift arms NOTE Some adjustment of the rollers may be necessary for free movement of t...

Страница 11: ...power cord open the door and remove the contactor box cover Position the unit to gain access to the rear and remove the lower back panel 2 Insert an appropriately rated power cord into the rear of th...

Страница 12: ...3 PHASE 4 WIRE WYE FIELD CONNECTION L1 L2 L3 N 1HV 1C1 2HV 1C2 3HV 1C3 1 2 3 4 5 6 FROM TRANSFORMER FROM TRANSFORMER 3 PHASE 3 WIRE DELTA FIELD CONNECTION L1 L2 L3 1HV 1C1 1 2 5 3 2HV 1C2 3HV 1C3 4 6...

Страница 13: ...C which conserves energy and water This feature is designed to keep the cooker in standby The SKIM feature when selected adds water for approximately 3 seconds once a minute It causes the water to ov...

Страница 14: ...eously the water will be raised to the boiling point At the end of the cooking cycle an alarm will sound briefly to alert you and the basket lift will automatically raise the basket or portion cups ou...

Страница 15: ...C 0 0 212 100 1000 305 210 99 2000 610 208 98 3000 915 207 97 4000 1220 205 96 5000 1525 203 95 6000 1830 201 94 5 Press the simmer switch 5BI the default setting for boil intensity appears 6 Use the...

Страница 16: ...the code 1 6 5 3 using the product buttons 3 2 Boiling Out the Cookpot The cookpot must be boiled out before first use 1 Close the drain valve and fill the cookpot with a mixture of cold water and 1 c...

Страница 17: ...oking residue Clean the outside of the cabinet with a clean cloth dampened with dishwashing detergent removing oil dust or cooking residue DANGER Never attempt to clean this equipment during the cooki...

Страница 18: ...sure that it doesn t happen again Keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system If the tr...

Страница 19: ...will not heat controller is on water is at normal level but LO is not showing on the controller A Dirty low water level sensor A Clean sensor B Insufficient mineral content in water B Add cup baking s...

Страница 20: ...w is within the allowed range as indicated on the appliance s rating plate Verify that the temperature and high limit probes are properly connected tightened and functioning properly and that mounting...

Страница 21: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 22: ...33 318 865 1711 WWW FRYMASTER COM EMAIL FRYSERVICE WELBILT COM 2021 Welbilt Inc except where explicitly stated otherwise All rights reserved Continuing product improvement may necessitate change of sp...

Отзывы: