Frymaster FR 3 Скачать руководство пользователя страница 12

 Deep Clean Mode JIB System

 (continued)

 

 

©McDonald’s Corporation · Planned Maintenance Manual · Revised June 2009 

Page 2 of 4

 

Enter Code. 

Enter 1-2-3-4 with the 
numbered keys 

Scroll to Deep Clean. 

Press the 

“Info” button to 

scroll to DEEP CLEAN 
MODE. 

 

Press checkmark key. 

Press the 1

D

 key under the 

vat to be cleaned. 

 

Confirm Deep Clean. 

The computer display 
alternates between DEEP 
CLEAN? and YES NO. Press 
the 1

D

 key.   

Confirm Oil is Removed. 

Split Pots:

 Computer 

displays Deep Clean, 
alternating with L R. Press the 
1

D

or 2

U

 button under the 

split vat to be cleaned. 
Computer displays IS OIL 
REMOVED? alternating with 
YES NO

.    

 

Full Pots:

 Computer displays 

IS OIL REMOVED? 
alternating with YES NO. 

10 

Confirm Pot Status. 

Empty Vat:

 Press the 1

D

 

key. Computer displays 
SOLUTION ADDED? 
alternating with YES. 
 

 

Oil-Filled Vat: 

Press the 2

U

 

key. Computer displays IS 
DISPOSAL UNIT IN 
PLACE? alternating with 
YES NO. 

 

 

11 

Drain oil from vat. 

Empty Vat:

 Skip to Step 12. 

 

Be sure the MSDU 
(McDonald’s Shortening 
Disposal Unit

 

or oil removal 

cart) is in place underneath 
the drain spout on the fryer.  

 

Full Vat:

 Press the 1

D

 key 

and let the oil drain into the 
oil removal cart. Push any 
pieces of fried food or other 
sediment into the drain valve, 
so they drain out. Computer 
displays DISPOSING 
changing to VAT EMPTY?  
 
Press the 1

D

 key. 

 

 

The oil may be very hot. 
Avoid splashing oil. 

 

 

 

 

 

 
 

12 

Replace filter pan. 

Place filter pan with all 
internal components removed 
in the fryer cabinet. 
 

 

13 

Add degreaser and hot water 
to vat. 

Pour McD Heavy-Duty 
Degreaser carefully into the 
vat. Use 2 gallons (8 liters) of 
degreaser if you are cleaning 
a full vat. Use 1 gallon (4 
liters) of degreaser if you are 
cleaning one side of a split 
vat. Finish filling the vat with 
hot water. Solution should be 
1 inch above fill line. 
 
Refer to Kay Chemical 
instructions Fryer Deep Clean 
Procedure for additional 
instructions. 

 

McD Heavy Duty Degreaser 

 

 

 

 
 

Frymaster BIELA14 and BIGLA30 – LOV Fryer 

Quart

erly 

FR 3 Q1 

Содержание FR 3

Страница 1: ...Clean Behind Fryer Bi weekly maintenance task FR 3 B1 Calibrate fryer Monthly maintenance task FR 3 M1 Calibrate fryer recovery time Quarterly maintenance tasks FR 3 Q1 Deep Clean Jib System FR 3 Q2...

Страница 2: ...heating element hub Wearing heat resistant gloves place covers on fry pots ensuring they are square with the frypot Spray EXCEED on a No scratch pad Use No scratch pad to clean around the element hub...

Страница 3: ...wringer Paper towels Putty knife Neoprene Gloves Procedure 1 Turn fryers off Turn all fryer power switches to the off position 2 Remove and empty grease trough and cup Remove the grease trough from th...

Страница 4: ...ve the fryer filters from the exhaust hood Take the filters to the three compartment sink and soak them in McD APSC McD APSC 7 Scrape area behind fryer Use a putty knife to scrape off all soft grease...

Страница 5: ...er towels 11 Mop floor around fryer Use a mop and a bucket of hot McD APSC solution to mop the entire floor around the fryer Floor may be wet from mop ping 12 Allow surfaces to dry Allow all fryer wal...

Страница 6: ...Lock wheels into place Rein stall the fryer filters and the grease trough in the exhaust hood 17 Turn on gas supply If the fryer is an electric fryer skip this step Turn the manual gas shut off valve...

Страница 7: ...ice wa ter and stir continuously until the temperature readout stabilizes 3 Read temperature The readout should be 32 F 0 C plus or minus 2 F 1 C If not you need to calibrate repair or replace the py...

Страница 8: ...are the temperature reading on the pyrometer with the corresponding tempera ture on the display If the two temperatures are less than 5 F 3 C apart ei ther plus or minus you do not need to adjust the...

Страница 9: ...ally re cords the fryer s recovery time each time the vat tem perature rises from 250 F 121 C to 300 F 149 C Press the INFO button The display will show the most recent recovery time in both displays...

Страница 10: ...ge power plug is properly plugged in Adjust as necessary For gas fryers only check the seal angle gravity blade and standoff Adjust their place ment if necessary For gas fryers only check the air flow...

Страница 11: ...cedure The Deep Cleaning follows procedures developed by Kay Chemical Their instructions are needed in addition to this PM 1 Prepare for Deep Clean and turn fryer off Put on neoprene gloves a heat res...

Страница 12: ...alternating with YES NO 11 Drain oil from vat Empty Vat Skip to Step 12 Be sure the MSDU McDonald s Shortening Disposal Unit or oil removal cart is in place underneath the drain spout on the fryer Ful...

Страница 13: ...e them when clean and take them to the three compartment sink Rinse and dry them thoroughly Do not place any aluminum parts in the boiling solution The solid metal basket hangers are made of aluminum...

Страница 14: ...The computer displays RINSE COMPLETE alternating with YES Press the 1Dbutton when the rinse is complete 25 Remove filter pan The computer displays REMOVE PAN Remove the filter pan 26 Dry Vat Clean an...

Страница 15: ...e The Deep Cleaning follows procedures developed by Kay Chemical Their instructions are needed in addition to this PM 1 Prepare for Deep Clean and turn fryer off Put on neoprene gloves a heat resistan...

Страница 16: ...illed Vat Press the 2U key Computer displays DRAINING changing to VAT EMPTY alternating with YES The oil may be very hot Avoid splashing oil 9 Vat empty Press the 1D key 10 Open dispose valve The comp...

Страница 17: ...DDED alternating with YES Press the 1D key 18 Start Deep Clean Computer displays DEEP CLEAN alternating with a countdown timer for one hour The solution will reach a temperature of 195 F 91 C The solu...

Страница 18: ...r Cleanser may be use also Once the vat is scrubbed press the 1Dbutton 25 Draining The computer displays DRAINING to drain the small amount of solution from the vat The solution will be very hot Avoid...

Страница 19: ...filled to the bottom oil level line 32 Fill the vat with oil The computer displays PRESS AND HOLD YES TO FILL alternating with YES Press and hold the 1Dbutton to fill the vat Release the button when...

Страница 20: ...val cart Neoprene Gloves Procedure 1 Prepare for tests Confirm that the oil in the fryer is scheduled to be changed The oil must be discarded at the end of the procedure Check the oil level in the fry...

Страница 21: ...14 High limit opens The computer displays HELP alternating with HI 2 when the high limit opens between 423 to 447 F 217 C to 231 C 15 High limit fails If the high limit fails to open the computer wil...

Страница 22: ...o scratch pad Procedure 1 Prepare fryer for procedure Check to make sure the fryer is cool This procedure should be done only when the fryer is cool and the filter pan is empty 2 Remove filter pan Pul...

Страница 23: ...y that heating elements are in good condition with no carbon caramelized oil build up Inspect the elements for signs of extensive dry firing 3 Tilt inspection Verify that the tilt mechanism is working...

Страница 24: ...sformers contactors etc are in good condition and free from oil build up or other debris 9 Wiring connection inspection Verify that component box and contactor box wiring connections are tight and tha...

Страница 25: ...high limit probes are properly connected tightened and functioning properly and that mounting hardware and probe guards are present and properly installed 4 Clean and Replace gas valve vent tube Clean...

Страница 26: ...ner isn t receiving enough air Dark spots on the burner usually mean the burner is receiving too much air When the microamp reading is in the acceptable range and the burner color is bright orange red...

Отзывы: