FGP55 SERIES GAS RETHERMALIZERS
CHAPTER 1: SERVICE PROCEDURES
1-7
1.6.2 Replacing the Temperature Probe (cont.)
6.
Loosen and unscrew completely the
compression nut, then the pass-through nut
from the cookpot. Proceed to the next step
before removing probe from cookpot.
Note:
The temperature probe can be
removed through the top of the cookpot as
follows: Ensure the two-pin connector has
been removed from the probe wiring harness
(step 4, this section). Remove the harness
insulation. The probe can be pulled through
the cookpot from the top (complete step 7 in
this section, prior to removing probe).
7.
Remove probe bracket and probe spring from
probe inside cookpot (bracket location and
configuration will vary according to
rethermalizer model). Retain mounting
hardware for installation of new temperature
probe.
8.
Carefully remove the probe from the cookpot.
As the probe is removed, tilt the probe at an
angle to facilitate removal (curved probes
only).
9.
Reverse steps for installation of new probe.
IMPORTANT:
When installing new probe,
ensure probe is positioned properly with the
mounting hardware installed prior to tightening
the compression nut
. Once tightened, the probe
cannot be repositioned.
Loosen and unscrew completely the compression
nut (bottom arrow), then the pass-through nut (top
arrow).
First remove the probe bracket (two screws), then
the probe spring. Retain mounting hardware for
installation of new probe.
First remove the probe bracket (two screws), then
the probe spring. Retain mounting hardware for
installation of new probe.
Removing old probe from cookpot. (Cookpot
removed from rethermalizer for clarity).