Example 1:
Input
Battery
Fronius
Ohmpilot
Number
of primary
meters
Number
of secondary
meters
Modbus 0 (M0)
0
4
0
2
0
1
Modbus 1 (M1)
1
3
Example 2:
Input
Battery
Fronius
Ohmpilot
Number
of primary
meters
Number
of secondary
meters
Modbus 0 (M0)
1
3
Modbus 1 (M1)
0
4
0
2
0
1
Multi meter sys-
tem - Fronius
GEN24 inverter
If several Fronius Smart Meters are installed, a separate address must be set for
each one (see
Set the address of the Fronius Smart Meter
primary meter always receives the address 1. All other meters are numbered
consecutively in the address range from 2 to 14. Different Fronius Smart Meter
power categories can be used together.
IMPORTANT!
Use no more than Use 7 secondary meters in the system. To avoid interference, it
is recommended to install the terminating resistors according to the chapter
.
21
EN-US